SPECIFICATIONS
Interior Dimensions
INCHES W x H x D
Exterior Dimensions
INCHES W x H x D
Cubic Foot Capacity
Unit Weight
Temperature Range
Ambient + 8
Standard Electrical: 230 volts, 50/60 Hz
Common Unit Specifications
Operating Environment: Indoor use, altitude up to 6,500 ft. (2,000m). Installation Category II,
Storage Temperature:
Approvals:
Compliance:
Common Unit Construction
Exterior: Powder-Coated Steel
Insulation: Fiberglass
Thermo-control: PID Microprocessor
Issue Rev C 0310
Copyright Quincy Lab Inc. 2009
Model Series 140AE-1 & 180AE-1 (230 V )
MODEL
10-140AE-1
10.5x9.38x10
26.6x23.81x25.4
(CM) W x H x D
13x15x11
33x38x28
(CM) W x H x D
23 lbs
o
C to:
200
WATTS
Pollution Degree 2, ambient temperature 10
80% RH maximum.
o
o
-10
C/14
Underwriter's Laboratory Listed, Laboratory Equipment, C/UL
United States / Canadian. E212550
UL Standard 61010-1, IEC 61010-1, 2nd Edition.
Quincy Lab, Inc.
1925 N. Leamington Ave.
General Purpose Incubators
MODEL
12-140AE-1
16x15.38x12
41.25x39.05x30.5
19x21x13
48x53x33
39 lbs
300
o
o
F to 70
C / 158
F, 70% RH maximum.
Interior: Aluminum
Door: 1
Heater: Resistive-Tubular Incoloy
Chicago, Illinois 60639
OPERATING MANUAL
Model 10-180AE-1
MODEL
10-180AE-1
10.5x9.38x10
26.6x23.81x25.4 41.25x39.05x30.5
13x15x11
33x38x28
23 lbs
365
o
o
o
C / 50
F to 35
C / 95
40AE-1: Acrylic, 180AE-1: Steel Insulated
1-800-482-HEAT (4328)
MODEL
12-180AE-1
16x15.38x12
19x21x11
48x53x33
39 lbs
465
o
F,
PAGE 1

Advertisement

loading

Summary of Contents for QL 140AE-1 Series

  • Page 1 Model Series 140AE-1 & 180AE-1 (230 V ) General Purpose Incubators OPERATING MANUAL Quincy Lab, Inc. Model 10-180AE-1 Model 12-140AE-1 MODEL MODEL MODEL MODEL SPECIFICATIONS 12-180AE-1 10-140AE-1 12-140AE-1 10-180AE-1 Interior Dimensions 10.5x9.38x10 16x15.38x12 10.5x9.38x10 16x15.38x12 INCHES W x H x D 26.6x23.81x25.4 41.25x39.05x30.5 26.6x23.81x25.4 41.25x39.05x30.5...
  • Page 2 Safety Precautions Read Operating Instructions Thoroughly Prior to Operation Read Operating Instructions thoroughly prior to operation. Use only a grounded outlet that is rated for your model's electrical requirement. Do not modify the oven or factory control settings to operate the oven above the stated maximum operating temperature.
  • Page 3 Control Menu Functions Access the menu levels for the following functions: (user applicable functions and FUNCTION SETTING their menu locations are high-lighted in white in the Functions Menu Guide below). Alternating ~ Change control to read in C or F temperature units.( in level 2) Display ~ Change to whole degree or 1/10th degree display resolution.(...
  • Page 4 TIP: To avoid erroneous tracking data from run-up temperatures or door openings, start the Tracking feature after articles have been placed and temperature steadies at set point. Control Self Diagnostics Control prompts will only display when a fault or alarm condition exists. Example for 140AE-1 series: PRESS (Press together to...

This manual is also suitable for:

180ae-1 series10-140ae-112-140ae-110-180ae-112-180ae-1