BST-MG0S/09 Multi-gas Detecting Alarm
1. Application: This product is designed to ensure safety for users who work in dangerous
places. It's used for detecting CO, 02, H2S, CH4 simultaneously and alarm users by light,
sound and vibration. This device is portable, anti-explosion and intrinsically safe.
2.
Features:
Measured gases: Combustible Gas(LEL/CH4), Oxygen(02), Carbon Monoxide(CO), and
1.
Hydrogen Sulfide(H2S). Contact manufacturer f o r other gas combinations.
2. It will alarm users by sound, vibration, and light with different intensity if actual
concentration is higher or lower than preset alarm points.
3.
Operation:
1. 4 buttons included. 0 On/Off button; OK button; .A.Up button; 'YDown button
2. Long press 0 On/Off button to activate the device. It will show below inf o rmation in
turn:
A. Product brand
B. Low Alarm [L)
C. High Alarm [HJ
D. STEL Alarm [SJ
E. TWA Alarm [TI
Preset calibration Value
F.
G. Product number and next calibrate date, 30 seconds countdown
H. Auto Zero option
BESANTEK
LOGO
3. In auto zero option, after seeing "Adjust Zero?", long press "OK" button to zero all
sensors, short press " 0 " button to exit. When the device is zeroed in unfresh air, the
system will zero itself when the device is back to fresh air, no need to worry about the
accuracy.
4. In main interface, it shows 4 alarm icons on top area: [LI, [HI, [SJ, [Tl, if there is any alarm,
the corresponding icon will turn red. Short press ".A." to switch among STEL, TWA, PEAK,
and MIN. No operation for 30 seconds will bring it back to main interface.
5. Long press "OK" button to enter function interface.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
LLJliU ALIIR)I [SJ[T] ll:ii!
[Pl'!!)
[PPM]
2Q16. 09. 22
Manual Instruction
.
�Ml �
0. 00
20 9
02
•
co
['l>l'OL]
0
H2S
0
II ::\i;
Main Interface
TestEquipmentDepot.com
II
/
Calibr-
-ation
Alarm
�
(9
Setting
Time
Function interface