C-TEC 800 Series Quick Start Manual

C-TEC 800 Series Quick Start Manual

Accessible toilet alarm

Advertisement

Quick Links

TECHNICAL SPECIFICATIONS
NC943B
Single Zone Call Controller c/w Sounder
Mains supply:
Voltage: 230Va.c. 50/60Hz; Max. current: 23mA.
Outputs:
PSU voltage 12Vd.c. / current 140mA.
Volt-free relay contacts (NO/C/NC) rated 30Vd.c. @ 1A.
Currents:
Zone current 18mA; Alarm current 23mA.
Battery backup:
500mA, rechargeable, 24 hours standby plus 15 minutes alarm run time.
Indicators:
Red alarm 'Calling' LED; Green power 'On' LED (flashes green when
battery backup is active).
Sounder:
Active in alarm, volume adjustable.
Controls:
'Call Accept' button (link selectable for accept, reset, or no function).
IP Rating
: IP31 when correctly installed.
(EN 60529)
Mounting:
Mounts on 25mm UK double gang back box (flush or surface).
Dimensions:
147 x 87 x 39mm (W x H x D).
Weight:
300g
o
o
Operating Temp.: -5
C to +40
C; Max. relative humidity (RH) 95% non-condensing.
NC807C
Ceiling / Wall Pull Unit
Input:
Voltage: 12Vd.c.; Connections: Signal and -Ve.
Pull cord:
3 metres cord length, generates an alarm call when activated.
Indicator:
Red reassurance LED, active in alarm.
IP Rating
: IP41 when correctly installed.
(EN 60529)
Mounting:
Ceiling or wall surface mountable.
Dimensions:
93mm diameter x 27mm deep.
NC806CS
Overdoor Light c/w Sounder
Input:
Voltage: 12Vd.c.; Connections: Signal, -Ve and +Ve.
Indicators:
Dual ultra-bright red LEDs, active in alarm.
Sounder:
Active in alarm.
IP Rating
: IP41 when correctly installed.
(EN 60529)
Mounting:
Mounts on 25mm UK single gang back box.
Dimensions:
87 x 87 x 68mm (W x H x D).
NC809DBBT
Accessible Toilet Reset Point c/w Sounder
Input:
Voltage: 12Vd.c.; Connections: Signal, -Ve and +Ve.
Indicator:
Red reassurance LED, active in alarm.
Sounder:
Active in alarm.
IP Rating
: IP41 when correctly installed.
(EN 60529)
Mounting:
Mounts on 25mm UK single gang back box.
Dimensions:
87 x 87 x 24mm (W x H x D).
E&OE. We reserve the right to alter product specifications at our discretion and without prior notice. This document has been
carefully checked prior to publication. However, no responsibility can be accepted by the manufacturer or distributors of this
equipment for any misinterpretation of an instruction or guidance note or for the compliance of the system as a whole.
Approved Document No.: DNU0951001 Rev 5 • Page 8 of 8
N C 9 5 1 • D E S I G N & I N S T A L L A T I O N G U I D E
Accessible Toilet Alarm
This equipment must be installed and maintained by a suitably skilled and technically
competent person.
This document provides a brief design and installation overview of the NC951 accessible
toilet alarm system, based on the recommendations of BS 8300 (the code of practice for the
design of buildings and their approaches to meet the needs of disabled people).
NC951
NC809DBBT
Accessible Toilet Reset Point c/w Sounder
Includes a 'Reset' button c/w braille text, red
reassurance LED and sounder.
R R E E S S E E T T
Indicators will operate:
Indicators will operate:
Continuously when pull cord is activated
Intermittently when help is on the way
Intermittently when help is on the way
Accessory Pack
Containing device
mounting screws
On
and shorting link.
NC943B
Single Zone Call Controller c/w Sounder
Includes a link selectable 'Call Accept'/'Reset' button,
'Calling' and power 'On' LEDs, 140mA PSU, backup
battery, volt-free relay output and sounder.
Single Zone Emergency Assistance Alarm
Approved Document No.: DNU0951001 Rev 5 • Page 1 of 8
KIT CONTENTS
NC807C
Ceiling / Wall Pull
Includes a red reassurance LED, red pull cord
and two triangular pull bangles.
NC949
Accessible WC
Sticker
Documentation
+
-
A Design & Installation
Calling
1
2
3
Guide (this document).
4
Call Accept
NC806CS
Overdoor Light c/w Sounder

Advertisement

loading

Summary of Contents for C-TEC 800 Series

  • Page 1 TECHNICAL SPECIFICATIONS N C 9 5 1 • D E S I G N & I N S T A L L A T I O N G U I D E NC943B Single Zone Call Controller c/w Sounder Accessible Toilet Alarm Mains supply: Voltage: 230Va.c.
  • Page 2 BASIC OPERATION The default operation of the NC951 is shown in the diagrams below. Raising an alarm call Inside the WC The distressed person raises The ceiling / wall pull’s red LED activates steady, an alarm call by pulling the the reset point’s red LED and sounder activate steady cord on the ceiling / wall pull.
  • Page 3 Indicators will operate: Up to three additional 800 Series devices (any device mix) can be connected to the NC943B Set the lower call controller. A typical expanded system is shown in figure 4 below. Should you wish...
  • Page 4 INSTALLING THE ACCESSIBLE TOILET ALARM SYSTEM ENGINEER SELECTABLE FUNCTIONS The NC943B call controller has a number of engineer selectable functions (refer to figure 3 ALWAYS ENSURE MAINS SUPPLY IS ISOLATED BEFORE MAKING ANY CONNECTIONS. below). This section explains how these functions work and how to set them. Figure 3 : Rear View of the NC943B Call Controller Refer to figure 1 (page 2) for wiring details.