Download Print this page

Eaton DA/EDA 103 Operation And Maintenance Manual

Pressure filters, change-over

Advertisement

Quick Links

Operations and Maintenance Manual
for Eaton Pressure Filters, Change-Over
DA/EDA 103,253,403,633,1003, related specification
This manual contains operation and maintenance information for series DA/EDA 103, 253, 403,
633, 1003 and related specifications. For customer specific models, there are additional instructions
on those data sheets. The pressure filters listed above are intended for the filtering of liquid media.
1. Safety instructions
WARNING: Avoid injury. Read and understand this manual before operating the filter.
FAILURE TO FOLLOW THIS WARNING COULD LEAD TO DEATH, SEVERE INJURY,
OR PROPERTY DAMAGE. Eaton does not assume liability for any damage that occurs to
due misuse of equipment.
WARNING: This filter is a pressure vessel designed to operate under specific
pressure, temperature, and other engineering parameters. Follow the operating
conditions specified on each data sheet. Operating outside of these parameters can cause
damage to important pressure holding parts and sealing. Pay special attention to excess
pressure, temperature range, and operating fluid. The compatibility of filter components with
the
operating
INCOMPATIBLE MATERIALS COULD LEAD TO PRODUCT FAILURE, LEAKAGE,
DEATH, SEVERE INJURY OR PROPERTY DAMAGE.
WARNING: Always wear safety goggles and gloves when working on the filter. Under
working conditions, the filter housing is pressurized. Do not try to loosen or remove any part
of the filter or the filter housing during operation. The operating fluid could escape at high
pressure and high temperatures. This does not apply to the offline vessel that is not under
operation. FAILURE TO FOLLOW THIS WARNING COULD LEAD TO DEATH, SEVERE
INJURY, OR PROPERTY DAMAGE.
WARNING: Leaking operating fluid can cause injury and burns. Equipment should be
shut down and isolated from energy sources and other equipment before any
inspection or servicing to prevent risk of shock or process fluid leakage. Do not open
the filter housing until you make sure it is not pressurized. The filter surface may be hot and
cause burns. When changing the filter, check the operating temperature before touching
any surface during operation. If you come into contact with the operating fluid, please follow
the safety instructions provided by the fluid manufacturer. FAILURE TO FOLLOW THIS
WARNING COULD LEAD TO DEATH, SEVERE INJURY, OR PROPERTY DAMAGE.
To ensure proper fit and function, only use Eaton spare parts.
2. Installation
The filter is supplied and delivered ready to be installed. The mounting position of the filter is vertical.
The filter has to be fitted with fastening screws in size and amount according to the corresponding
fastening bore holes of the filter housings. The filter should be mounted to minimize tensile forces on the
filter housing and change-over valve. The piping should be connected with flanges.
During installation ensure that:
-
No dirt and no impurities of foreign fluids penetrate the filter.
-
The connections for input and output are correctly attached to the pipe system.
-
The pipe system is connected to the filter to minimize stress on the filter.
-
Ensure the filter element is accessible for service and change out.
Clogging indicators should be installed according to the instructions on the unit specific data sheet and
the instructions in this manual.
fluid
should
always
be
considered
before
Sheet No.
67630-4D
Page 1/4
operation.
USE
OF

Advertisement

loading

Summary of Contents for Eaton DA/EDA 103

  • Page 1 DA/EDA 103,253,403,633,1003, related specification Page 1/4 This manual contains operation and maintenance information for series DA/EDA 103, 253, 403, 633, 1003 and related specifications. For customer specific models, there are additional instructions on those data sheets. The pressure filters listed above are intended for the filtering of liquid media.
  • Page 2 8. Switch to the filter housing you would like to operate first by using the switch gear lever. 9. After finishing step 7, tighten the locking screws. After following these instructions for commissioning, the serviced filter vessel is ready for operation. DA/EDA 103-1003 (illustration can slightly differ for different sizes)
  • Page 3 Microglass (VG) or paper (P) filter media CANNOT be cleaned and need to be replaced when it reaches the dirt holding capacity. Wire mesh (G) filter media can be cleaned and used again. Follow the cleaning specification for Eaton filter elements, sheet no. 21070-4 and 39448-4 to clean wire mesh filter media.
  • Page 4 PROPERTY DAMAGE. 8. Service For product technical support and service, please contact the local Eaton support team. All locations and contact information are listed below. Order spare parts and wearing parts according to the spare parts list on the filter data sheet.

This manual is also suitable for:

Da/eda 253Da/eda 403Da/eda 633Da/eda 1003