Banner SureCross FlexPower DX99 Series Manual

Thermocouple node, polycarbonate housing

Advertisement

Quick Links

SureCross DX99 FlexPower Thermocouple Node
(Polycarbonate Housing)
Switch configurable temperature Node with thermocouple/thermistor inputs and two discrete inputs (powered by external battery module
only)
For additional information, updated
documentation, and accessories, re-
fer to Banner Engineering's website,
www.bannerengineering.com/sure-
cross.
Model
DX99N9X2S2N0T4X0A0
DX99N2X2S2N0T4X0A0
Internal antenna models are also available. For more information, contact your local Banner Engineering Corp. representative.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
SureCross User Configuration Tool
Setting Up Your Wireless Network
To set up and install your wireless network, follow these steps.
Disconnect the power from your SureCross devices.
1. Configure the DIP switches of all devices.
2. Connect the sensors to the SureCross devices.
P/N 142498 Rev. E
The SureCross® wireless system is a radio frequency network with integrated I/O that can oper-
ate in most environments and eliminate the need for wiring runs. DX99 wireless networks are
formed around a Gateway, which acts as the wireless network master device, and one or more
Intrinsically Safe Nodes.
• Wireless industrial I/O device with two selectable discrete inputs and up to three configurable
thermocouple inputs (defaults to J-type)
• FlexPower® power input requires power from the DX81H Battery Supply Module
• One thermistor input used for integrated cold junction compensation (CJC)
• DIP switches for user configuration
• Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multiple Access
(TDMA) control architecture ensure reliable data delivery within the unlicensed Industrial,
Scientific, and Medical (ISM) band
• Transceivers provide bidirectional communication between the Gateway and Node, including
fully acknowledged data transmission
• Lost RF links are detected and relevant outputs set to user-defined conditions
• DX99 Polycarbonate housings are certified for use in Class I, Division 1, Groups A, B, C, D;
and Zone 0 (Category 1G) when properly installed in accordance with the National Electrical
Code, the Canadian Electrical Code, or applicable local codes/regulations
Frequency
I/O
900 MHz ISM Band
Inputs: Two selectable discrete, three thermocouple, one thermistor
(for CJC)
2.4 GHz ISM Band
The User Configuration Tool (UCT) offers an easy way to link I/O points in your wire-
less network, view I/O register values graphically, and set system communication pa-
rameters when a host system is not part of the wireless network.
The UCT requires a special USB to RS-485 (model number BWA-UCT-900 for 1 Watt
radios, BWA-HW-006 can be used for all other radios) converter cable to pass infor-
mation between your computer and the Gateway. Download the most recent revi-
sions of the UCT software from Banner Engineering's website:
gineering.com/wireless.
6/21/2013
http://www.banneren-
0 142498
0

Advertisement

loading

Summary of Contents for Banner SureCross FlexPower DX99 Series

  • Page 1 DX99N2X2S2N0T4X0A0 2.4 GHz ISM Band Internal antenna models are also available. For more information, contact your local Banner Engineering Corp. representative. WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death.
  • Page 2: Configuring The Dip Switches

    SureCross DX99 FlexPower Thermocouple Node (Polycarbonate Housing) 3. Apply power to all devices. 4. Form the wireless network by binding the Nodes to the Gateway. If the binding instructions are not included in the datasheet, refer to the product manual for binding instructions. 5.
  • Page 3 SureCross DX99 FlexPower Thermocouple Node (Polycarbonate Housing) Switches Device Settings Thermocouple, E-Type Thermocouple, G-Type Thermocouple, K-Type Thermocouple, L-Type Thermocouple, M-Type Thermocouple, N-Type Thermocouple, P-Type Thermocouple, R-Type Thermocouple, S-Type Thermocouple, T-Type Thermocouple, U-Type Modbus or UCT configured (overrides DIP switches) * Default configuration ** In high resolution mode, the temperature = (Modbus register value) ÷...
  • Page 4 SureCross DX99 FlexPower Thermocouple Node (Polycarbonate Housing) Thermocouple Range °F Range °C Type B 212 to 3,272 °F 100 to 1,800 °C Type C 32 to 4,208 °F 0 to 2,320 °C Type E -58 to 1,832 °F -50 to 1,000 °C Type J -292 to 1,382 °F -180 to 750 °C...
  • Page 5: Specifications

    SureCross DX99 FlexPower Thermocouple Node (Polycarbonate Housing) Modbus Register Table (High Resolution Mode, DX99) Modbus Holding Register I/O Type Units I/O Range Holding Register Val- Terminal Block Labels Gateway Any Node Min. Max. Min. Max. (Dec.) (Dec.) 1 + (Node# × 16) Discrete IN 1 2 + (Node# ×...
  • Page 6 SureCross DX99 FlexPower Thermocouple Node (Polycarbonate Housing) Radio General 2.4 GHz Compliance Interface FCC ID UE300DX80-2400 - This device complies with FCC Indicators: Two bi-color LEDs Part 15, Subpart C, 15.247 Buttons: Two ETSI/EN: In accordance with EN 300 328: V1.7.1 (2006-05) Display: Six character LCD IC: 7044A-DX8024 Wiring Access...
  • Page 7: Banner Engineering Corp Limited Warranty

    Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period.
  • Page 8 ER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.

This manual is also suitable for:

Surecross flexpower dx99n9x2s2n0t4x0a0Surecross flexpower dx99n2x2s2n0t4x0a0