SPECIFICATIONS JARO-BTP PORTABLES Parameter BTP20.12 BTP50.12 BTP75.12* 20Ah 50Ah 75Ah Capacity 12,8V Voltage nominal 11,0 - 14,6V Output voltage range 30lbs 55lbs 65lbs Maximum motor thrust 14,5V ±0,2V Voltage during charging Maximum charge current <10A <25A <40A Recommended charge current -20 - 50°C Temperature during discharge 0 - 45°C...
Page 3
SPECIFICATIONS JARO-BTP PORTABLES Parameter BTP100.12* BTP125.12 BTP50.24+12 100Ah 125Ah 50Ah Capacity 12,8V 25,6V Voltage nominal 11,0 - 14,6V 22,0 - 28,6V Output voltage range 80lbs 80lbs 80lbs 24V Maximum motor thrust 14,5V±0,2V 29,0 ± 0,2V Voltage during charging 100A 100A Maximum charge current <40A <40A...
This is to avoid large current spikes across one battery as the other batteries would fail. When connecting in parallel, special attention must be paid to the connecting wiring. Ask for advice from JAROCELLS B.V.. Charging and discharging >...
Page 5
> The battery must not be charged with damaged cables. Check this before charging the batteries. > Use the charger in a dry environment. The charger should not come into contact with moisture unless it is a waterproof charger. > Rapid temperature changes can lead to condensation.
General All information that is available within the battery about the degree of charge, power consumption, voltage, temperature, etcetera is made available via a wireless bluetooth connection to be read via our JAROCELLS App on an Android or Apple device.
What to do if the connection to the battery is lost? “Kill” the JAROCELLS App and restart the App. NOTE: By “Kill the App” we mean that the App must be complete be turned off and not just closed. You do this as follows:...
Page 8
We’ve got the power JAROCELLS B.V., Waldorpstraat 345, 2521 CJ Den Haag, The Netherlands. info@jarocells.nl / www.jarocells.nl NEXT GENERATION BATTERY PACKS...