Download Print this page

Linear 2 GIG Go!Bridge Quick Start Manual

Ip communicator

Advertisement

Quick Links

INSTRUCTIONS: FILE: 77-000044-001-BRDG1-900-INSTALL-INSTRUCTIONS-REVB-PRT-EN.PDF - DATE: 5/5/2014 - INK: BLACK - MATERIAL: 20 LB MEAD BOND - SIZE: 8.5"X11" - SCALE: 1 - PRINTING: FRONT AND BACK - FOLDING: FOLD TO FIT IN BOX - PAGES: 3
2GIG-BRDG1-900
Go!Bridge IP Communicator
INSTALL INSTRUCTIONS
The Go!Bridge™ IP Communicator (2GIG‐BRDG1‐900) provides 
Internet connectivity between the monitoring service's Central Station 
and the Go!Control® Panel (requires the 900 MHz Transceiver (2GIG‐
XCVR)). 
It supports automatic firmware updates, provides interactive security 
services, and increases supervision using signal‐forwarding to the 
Central Station. To communicate wirelessly with the control panel, the 
900MHz Transceiver Module (2GIG‐XCVR) must be installed in the 
panel and the Go!Bridge must be connected to the local network 
router using an Ethernet cable (not provided).
Box Contents
Verify that the package includes the following:
• 1—Go!Bridge 
• 1—5‐V DC USB Mini‐B Power Supply
• 1—Stand
Requirements
Before you install, program, and test the Go!Bridge, ensure the control 
panel being paired with the Go!Bridge meets these requirements:
• Firmware Version 1.12 (or higher)
• 2GIG‐XCVR 900 MHz Transceiver
To protect data sent via the local wireless network, is it 
NOTE:
recommended that you install the Go!Bridge on a local 
network where WPA (Wi‐Fi Protected Access) or WEP (Wire 
Equivalent Privacy) Encryption is already enabled.
After installing, programming, and testing the Go!Bridge, you will need 
to register a new customer with the third‐party monitoring service. 
See Registration on page 2.
Figure 1 Go!Bridge Front View—LED Indicators and Learn Button
A
Network LED
B
900 MHz LED
C
Learn button
Powering ON the Go!Bridge
Use these steps to power ON the Go!Bridge:
1
Ensure the Go!Bridge is connected to a power source. 
Do not connect an Ethernet cable to the Go!Bridge at this 
NOTE:
time. You will connect the cable when completing the steps in 
Programming the Go!Bridge into the Control Panel.
2
(Optional) Place the stand (provided) on a counter, desktop, or 
other flat surface. Set the Go!Bridge in the stand.
3
Verify that the two LEDs on the Go!Bridge illuminate in RED (see 
Figure 1  Go!Bridge Front View—LED Indicators and Learn Button). 
If the 900MHz LED illuminates in GREEN (the lower LED), 
NOTE:
verify that the network cable is not connected to the 
Go!Bridge. If the cable is disconnected and it is still illuminated 
GREEN, use the end of an open paperclip to press and release 
the recessed Reset button. The button is located inside the 
small hole on the port side of the Go!Bridge, directly above 
the Ethernet port. This restores the factory settings. See Figure 
2  Go!Bridge Rear View—Ports and Recessed Reset Button.
Figure 2 Go!Bridge Rear View
Ports and Recessed Reset Button
A
Recessed Reset button
B
Ethernet port
C
Power supply port
4
After the Go!Bridge is powered ON, continue with Programming 
the Go!Bridge into the Control Panel.
Programming the Go!Bridge into the Control
Panel
Use these steps to place the control panel and Go!Bridge in learning 
mode. This gives the control panel the ability to learn the network 
settings transmitted by the Go!Bridge. 
To scroll between op ons on the control panel, tap the ← 
NOTE:
and → arrows. To move to the previous or next prompt tap the 
↑ and ↓ arrows. 
1
Connect an Ethernet cable (not included) to the router and 
Go!Bridge. 
Ensure the control panel is powered ON. Then tap the Home 
2
button. 
Tap the system logo in the lower‐right corner of the control panel 
3
Home screen.
4
At the Enter Your Code page, enter your 4‐digit installer code to go 
to the Installer Toolbox (page 1 of 2) page.
At the Installer Toolbox (page 1 of 2) page, tap System 
5
Configuration.
At the Q1: Select RF Sensor # (01 to 48) page, tap Go To. 
6
At the Enter Question Number (2 Digits) page, enter 92.
7
8
At Q92 Select Network Device (0 to 1), tap → to scroll to (1) 
Go!Bridge. Then tap ↓.
At Q: Network Device ID (Read Only), tap Learn. This gives the 
9
panel the ability to discover the read‐only network device ID 
transmitted by the Go!Bridge.
At the Pair with Xcvr Device page, the "initiating learning process" 
message appears.
 
1
Copyright © 2014 Linear LLC

Advertisement

loading

Summary of Contents for Linear 2 GIG Go!Bridge

  • Page 1 Connect an Ethernet cable (not included) to the router and  Go!Bridge.  Ensure the control panel is powered ON. Then tap the Home    button.  Tap the system logo in the lower‐right corner of the control panel  Home screen. At the Enter Your Code page, enter your 4‐digit installer code to go  to the Installer Toolbox (page 1 of 2) page. At the Installer Toolbox (page 1 of 2) page, tap System  Configuration. Network LED 900 MHz LED At the Q1: Select RF Sensor # (01 to 48) page, tap Go To.  Learn button At the Enter Question Number (2 Digits) page, enter 92. Powering ON the Go!Bridge At Q92 Select Network Device (0 to 1), tap → to scroll to (1)  Use these steps to power ON the Go!Bridge: Go!Bridge. Then tap ↓. At Q: Network Device ID (Read Only), tap Learn. This gives the  Ensure the Go!Bridge is connected to a power source.  panel the ability to discover the read‐only network device ID  Do not connect an Ethernet cable to the Go!Bridge at this  NOTE: transmitted by the Go!Bridge. time. You will connect the cable when completing the steps in  At the Pair with Xcvr Device page, the “initiating learning process”  Programming the Go!Bridge into the Control Panel. message appears. (Optional) Place the stand (provided) on a counter, desktop, or  other flat surface. Set the Go!Bridge in the stand. Copyright © 2014 Linear LLC...
  • Page 2 Should the local network lose Internet access due to a power outage  Then tap Save Changes.  or interruption, the Go!Bridge is not equipped with a battery backup  system. To best prepare for power failures and to ensure the security  Tap Exit to the close the System Configuration.  system maintains Internet access with the monitoring service for life‐ LED Indicators safety communications during power failures, the local network must  have a dedicated Uninterrupted Power Supply (UPS) or battery backup  The table below details the LED colors for the Go!Bridge: solution from a third‐party manufacturer in place. Linear LLC does not  Network LED Globe Icon supply, provide, recommend, or test the Go!Bridge with any UPS or  Solid GREEN Indicates the presence of an external network connection. battery backup solution. It is also assumed that owner’s Internet  Flashing GREEN Network cable is plugged in and IP address is actively being  Service Provider (ISP) maintains a backup battery (or power generator)  assigned. for their remote network equipment.  Solid RED Network cable unplugged. 900 MHz LED Icon Labeled “900MHz” Solid GREEN Linked and communicating with the control panel. Flashing GREEN Linked to the control panel. Communication issues exist. Solid RED Not linked to the control panel, turns solid after a device reset. Flashing RED Not linked to the control panel. Copyright © 2014 Linear LLC...
  • Page 3 • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from  that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help Any changes or modifications not expressly approved by the party  responsible for compliance could void the user’s authority to operate  the equipment. Les changements ou modifications non approuvés expressément par  la partie responsable de la conformité pourrait annuler l'autorité de  l'utilisateur à faire fonctionner l'équipement. Industry Canada Notices This device complies with Industry Canada license‐exempt RSS  standard(s). Operation is subject to the following two conditions: (1)  this device may not cause interference, and (2) this device must accept  any interference, including interference that may cause undesired  operation of the device. For technical support in the USA and Canada: 855‐2GIG‐TECH (855‐244‐4832) Le présent appareil est conforme aux CNR d'Industrie Canada  Email: 2gigtechsupport@linearcorp.com applicables aux appareils radio exempts de licence. L'exploitation est  Visit web site for technical support hours of operation autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas  produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter  For technical support outside of the USA and Canada: tout brouillage radioélectrique subi, même si le brouillage est  Contact your regional distributor susceptible d'en compromettre le fonctionnement. Visit dealer.2gig.com for a list of distributors in your region PN: 77‐000044‐001 Rev. B Copyright © 2014 Linear LLC...

This manual is also suitable for:

2gig-brdg1-900