Download Print this page

Absolute Process Instruments APD 1401 Quick Start Manual

Rtd/thermistor input alarm trips, isolated, factory configured

Advertisement

Quick Links

RTD/Thermistor Input Alarm Trips, Isolated, Factory Configured
Input:
Input:
2 or 3 Wire RTD
2, 3, or 4 Wire RTD or Thermistor
Output:
Output:
Two 8 Amp DPST Relays
Two 8 Amp SPDT Relays
O Factory Set Input Type and Temperature Range
O Adjustable Trip and Reset Potentiometers
O Input LoopTracker
®
and Alarm Status LEDs
O Full 1200 V Isolation
O Alarm Test, Optional Latching Reset Button
O RTD Leadwire Compensation
Applications
Q Process Limit Alarm
Q Monitor, Heaters, Refrigerators, Ovens
Q Process Signal Over or Under Alarms
RTD or Thermistor Input, Factory Configured
Specify temperature range in °F or °C and sensor type
Minimum span: 100°F (55°C) or consult factory
RTD types:
Specify type listed below and if 2, 3, or 4 wire
For others provide resistance at 0°C and curve
100 Ω 0.00385 DIN
100 Ω 0.003916
100 Ω 0.00392
10 Ω Cu
1000 Ω Ni-Fe
120 Ω Ni
RTD leadwire compensation: < ±0.05% of
span per 1 Ω change in leadwire resistance
Thermistors: Specify type listed below. For other sensor types
provide temperature-resistance chart.
44004/44033 2.252 kΩ at 25°C
44005/44030 3.000 kΩ at 25°C
44007/44034 5.000 kΩ at 25°C
44006/44031 10.00 kΩ at 25°C
44008/44032 30.00 kΩ at 25°C
YSI 400 2.252 kΩ at 25°C
Spectrum 1003k 1 kΩ
Isolation
Power to input isolation:
1200 V
Common mode protection:
600 VAC
p
LoopTracker
Variable brightness LED indicates input level and status
APD 1401 Relay Output
Single setpoint dual DPST contact sets, field configurable
2 Form A (NO) and 2 Form B (NC) contact sets (8 terminals)
May be field wired for Form C operation
One set point, 12 turn potentiometer, 0-100% of span
One reset point, 12 turn potentiometer, 0-100% of span
Factory configured alarm
Standard:
HI alarm, non-latching, normal acting
APD 1421 Relay Output
2 independent setpoint DPST contact sets, field configurable
SP 1: Form A (NO) and Form B (NC) contacts (4 terminals)
SP 2: Form A (NO) and Form B (NC) contacts (4 terminals)
May be field wired for Form C operation
Two set points, two 12 turn potentiometers, 0-100% span
Two reset points, two 12 turn potentiometers, 0-100% span
Factory configured alarm
Standard:
HI/LO alarm, non-latching, normal acting
Options:
LO/LO, HI/HI, LO/HI alarms, band alarms,
latching, reverse acting
Relay Contact Ratings
8 A max @ 240 VAC
AC inductive load
(cos f = 0.4)
resistive load.
8
External contact
5
protection such as
3
an RC snubber is
DC inductive load
1
recommended for
(L/R = 7 ms)
inductive loads.
0.5
DC resistive
0.3
load
0.1
0
3 5 10
Response Time
Switching Voltage (V)
300 milliseconds
typical
Output Test/Reset Button
Front button or external contact closure toggles relays to
opposite state when pressed.
Resets relay if latching relay option is ordered
A
A
P
P
BSOLUTE
BSOLUTE
ROCESS
ROCESS
New Microprocessor-Based Versions
Removable Plugs
Alarm Test Function
Two 8 Amp SPDT
Alarm Relays
Input LoopTracker LED
Alarm Status LED
Adjustable Deadband
Adjustable Setpoint
Custom Input Ranges
Universal Power
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
Made in USA
or 600 VDC
Applications Link
api-usa.com/apps
Ambient Temperature Range and Stability
–10°C to +60°C operating ambient
Better than 0.04% of span per °C
Dimensions
0.89" W x 4.62" H x 4.81" D (22.5 x 117 x 122 mm)
Height includes connectors
Housing and Connectors
IP 40, requires installation in panel or enclosure
For use in Pollution Degree 2 Environment
Mount vertically to a 35 mm DIN rail
Four 4-terminal removable connectors, 14 AWG max wire size
Power
85-265 VAC, 50/60 Hz or 60-300 VDC, 2 W maximum
D versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 2 W maximum
Model
APD 1401
AC resistive
load
APD 1401 D
APD 1421
APD 1421 D
Options—add to end of model number
L
APD 1401 with LO trip. Alarm trips on decreasing signal.
HH APD 1421 with HI/HI trip. Alarms trip at their respective
trip points on increasing signal.
30 50 100 300 500
LL APD 1421 with LO/LO trip. Alarms trip at their respec-
tive trip points on decreasing signal.
LH APD 1421 with LO/HI trip. Alarm 1 trips on decreasing
signal. Alarm 2 trips on increasing signal.
BA APD 1421 with band alarm. Alarm trips if signal is out-
side LO and HI trip points.
I
I
NSTRUMENTS
NSTRUMENTS
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16
Free Factory
I/O Setup!
Input
Standard Alarm Configuration
HI alarm, single setpoint, dual DPST relays
Factory ranged, specify
sensor type,
°F or °C range
HI/LO alarms, 2 setpoints, 2 DPST relays
Options if required
1220 American Way Libertyville, IL 60048
Phone:
800-942-0315
APD 1401, APD 1421
Quick Link:
Quick Link:
1 2 3 4
5 6
7 8
9 10 11 12
13 14 15 16
Pb
Description
The APD 14x1 series accepts an RTD or thermistor tempera-
ture input and provide a visual alarm indication and alarm
relay contact outputs.
The input type, range, and alarm types are factory configured.
The input can be configured for most RTDs or thermistors.
Front-accessible potentiometers are used to adjust alarm trip
and reset point(s).
LoopTracker and Alarm Status LEDs
API exclusive features include a LoopTracker LED that varies
in intensity with changes in the process input signal.
A red/green bicolor alarm status LED (two on the APD 1420)
visually indicate alarm status.
These LEDs provide a quick visual picture of your process
at all times.
Output Test / Unlatch
API's exclusive Output Test button can be used to verify the
alarm and system operation and also provides the additional
function of unlatching the alarm when the latching option has
been ordered.
The output test button greatly aids in saving time during initial
startup and/or troubleshooting.
non-latching, normal acting
non-latching, normal acting
IBA APD 1421 with inverse band alarm. Alarms trip if signal
is between LO and HI trip points.
HT Latching alarm with push button reset
HP Latching alarm with power-off reset. Module power
must be turned off to reset alarms
R Reverse-acting alarms. Relay coils energized in an alarm
condition. No alarm condition with module power off.
U
Conformal coating for moisture resistance
Accessory—order as separate line item
API BP4 Spare removable 4 terminal plug, black
api-usa.com
Fax: 800-949-7502
api-usa.com/1400
api-usa.com/1000
See Wiring
Diagrams on
Next Page
Lead
Free
Power
85-265 VAC or 60-300 VDC
9-30 VDC or 10-32 VAC
85-265 VAC or 60-300 VDC
9-30 VDC or 10-32 VAC
© 07-20

Advertisement

loading

Summary of Contents for Absolute Process Instruments APD 1401

  • Page 1 Options—add to end of model number IBA APD 1421 with inverse band alarm. Alarms trip if signal (L/R = 7 ms) inductive loads. APD 1401 with LO trip. Alarm trips on decreasing signal. is between LO and HI trip points. DC resistive load HH APD 1421 with HI/HI trip.
  • Page 2 LED indicates an alarm condition. 11 12 The APD 1401 operates two sets of relays in unison with a In the normal mode of operation, the relay coil is energized single setpoint. The dual DPST contact sets are in a Form C in a non-alarm condition and de-energized in an alarm configuration.

This manual is also suitable for:

Apd 1401 dApd 1421Apd 1421 d