ORIGINAL INSTALLATION & OPERATING INSTRUCTIONS
The Herschel Aspect XL consists of 2 or 3 highly emissive ceramic heating elements mounted in a directional, reflective unit. It is designed
to gently warm people using infrared heat. Infrared Heat is a 100% natural radiating heat that humans readily absorb, producing a feeling
of great comfort and well-being. Infrared Heat produced from the Herschel IR warms you directly without heating the air in between :
meaning the heat goes where you want it.
The system is easy to install; extremely discreet, produces no red light and requires next to no maintenance.
CAUTION:
The Herschel Aspect XL rises to very high temperatures in use and the unit (in particular the ceramic surfaces) must not be touched when
power is applied. Do not touch the unit when this is on. After switch off the elements remain hot for a considerable time and the unit should
not be touched within 30 minutes minimum after heater has been switched off.
Please attach the supplied notice (CAUTION DO NOT TOUCH HEATER) to the wall near the heater or in a location where it can easily be seen.
Never use the heater to ignite materials.
Particular attention has to be given where children and vulnerable people are present. The Aspect XL is not to be used by children or persons
with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given instruction or are
under supervision. Children of less than 3 years should be kept away unless continuously supervised. Children should be supervised to ensure
they do not play with the appliance.
Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its
intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or
perform user maintenance.
To avoid a fire hazard, do not cover the heater in any manner and ensure there is adequate air circulation around the heater. The Appliance
shall, under no circumstances, be covered with insulating material or similar material.
The heater must not be used if the Ceramic panels are damaged. If the power supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a hazard.
WARNING:
This heater is not equipped with a device to control the room temperature. Do not use this heater in small rooms when they are occupied by
persons not capable of leaving the room on their own, unless constant supervision is provided.
IMPORTANT INFORMATION:
Please read the following information fully, as safe and reliable operation depends on correct installation. Please keep this instruction sheet
for future reference.
The AC mains supply is dangerous and potentially lethal. Ensure the mains supply is switched off at the consumer unit (fuse box) before
attempting any work on electrical circuits. Wiring to this unit must be connected in accordance with the relevant national electrical safety
standards. This unit must only be installed by a competent and qualified electrician. This appliance must be earthed.
Do not disassemble : no user-serviceable parts inside.
ELECTRICAL INFORMATION:
The electrical supply to the unit should be provided by connecting to a circuit, which is protected by a fuse or miniature circuit breaker suitable
for the electrical rating of the unit and in accordance with Table 1 or Table 2. The supply to the heater must be switched separately using a
switch appropriately rated for the load and supply voltage. A switched fused spur may also be used on existing ring main circuits where the
XL2/XL3 V1.6 260416
Page 1

Advertisement

loading

Summary of Contents for Ceramicx HERSCHEL ASPECT XL2

  • Page 1 HERSCHEL ASPECT XL2 - HERSCHEL ASPECT XL3 Wall-mounted Infrared Heaters IPX4 rated (ceramic elements) MODEL: AXL2/0416 AXL3/0416 IPX4 XL2/XL3 V1.6 260416 ORIGINAL INSTALLATION & OPERATING INSTRUCTIONS The Herschel Aspect XL consists of 2 or 3 highly emissive ceramic heating elements mounted in a directional, reflective unit. It is designed to gently warm people using infrared heat.
  • Page 2 The cable outlet current carrying capacity must be greater than the recommended fuse current rating given in Table 1 or Table 2. 138 mm 550 mm 800 mm Herschel Aspect XL2 Herschel Aspect XL3 Table 1 Specifications Table 2...
  • Page 3 The Herschel Aspect XL MUST NOT be installed at a height of less than 2.3m (90”). Heater must not be located immediately below a socket outlet. Joists, beams and rafters shall not be cut or notched to install the appliance. The distance between the sides of the heater and the sides and any adjacent ceiling recessed heater shall not be less than four times the minimum distance specified for the distance between the sides of the heater and any building element adjacent to it.

This manual is also suitable for:

Herschel aspect xl3Herschel axl2/0416Herschel axl3/0416