Download Print this page
HPM Forta Instruction Manual

HPM Forta Instruction Manual

Led floodlight

Advertisement

Quick Links

Read all the instructions before installation. This instruction manual is to
be left at the installation site. These Floodlights must only be connected to
a 230V-240Va.c. 50Hz supply by a licensed electrician.
FORTA
Fig 1
LFL0130WBL
1
6
1 Lamp Cover Screw
2 Terminal Block
3 Junction Box Cover Screws (x 4pcs)
4 Wall Mounting Bracket Screws (x 2pcs)
5 Wall Mounting Bracket
6 Gland
7 Power Cable (not provided)
Where to mount your flood light:
1. Installation is to be made in dry weather conditions.
2. Choose a wall mount position that is in a sheltered location (e.g under
the eaves of the house). A mounting height of greater than 2m
is recommended.
3. Do not operate in close proximity to combustible materials or
substances affected by heating or drying. Keep a minimum distance
of 0.5m from adjacent objects.
2
3
4
5
7
Cat. Nos. LFL0110WBL, LFL0120WBL, LFL0130WBL, LFL0140WBL
Installation:
Installing a wall switch adjacent to the power source is recommended.
1. Remove mounting bracket from the fitting and use to mark position on
the wall/ceiling.
2. Mount the bracket on the wall/ceiling. Ensure the method of fixing can
support up to a 10kg weight.
3. Reattach fitting to the bracket.* Do not tighten bolts completely
to allow for mains wiring termination.
* Ensure that cord gland faces downwards in the final mounting
position (as shown in Fig.1)
Blue wire to Neutral
Green-yellow to earth
Brown wire to switch
Fig 2
4. Choose rubber-sheathed 3-core circular cord, H05RN-F 3G 1mm2
(not supplied) for the mains wiring.
5. Remove junction box cover, strip insulation from cord and insert in to
cord gland. Wire up as shown in Fig 2.
6. Replace junction box and tighten screws to ensure a weatherproof
seal. Tighten gland
7. Orient fitting to desired position and tighten bolts completely.
Forta LED Floodlight
Instruction Manual
White wire to light
N
N
Green-yellow to light
White wire to light
L
L

Advertisement

loading

Summary of Contents for HPM Forta

  • Page 1 Forta LED Floodlight Cat. Nos. LFL0110WBL, LFL0120WBL, LFL0130WBL, LFL0140WBL Instruction Manual Read all the instructions before installation. This instruction manual is to Installation: be left at the installation site. These Floodlights must only be connected to a 230V-240Va.c. 50Hz supply by a licensed electrician.
  • Page 2 H05RN-F 3G 1mm requirement: Warranty Customer Service HPM Legrand warrants this product for a period of 3 years from the For all Customer Service and Technical Support date of purchase. please call Monday to Friday during business hours. These goods come with guarantees that cannot be excluded under HPM Legrand Australia the Australian and New Zealand Consumer Laws.

This manual is also suitable for:

Lfl0110wblLfl0120wblLfl0130wblLfl0140wbl