Description of Functions
1.
Increased MPP charging current compared with conventional controllers, due to ultramodern controller technology
(microprocessor) by 10 % to 30 % (efficiency > 95 %)
2. Switchable characteristic lines of charging for optimum charging of Gel/dryfit/AGM/fleece or acid/lead-acid, as well
as LiFePO4 batteries .
3. Two Battery Charging Ports: Automatic charging of the main battery or board battery (Board I):
Support charging and trickle charging (max. 1 A) of the vehicle's starter battery (Start II) with overcharge protection
4. Unattended Charging: Standard protection against overload, overheating, reverse battery and back discharge of the
battery (in case of insufficient solar power, such as at twilight, at night etc.).
5. Overcharge protection: Reduction of the charging current of the battery in case of excessive solar power and full
battery. Immediate recharging in case of power consumption to ensure always the best possible charging state of the
battery.
6. Connection for temperature sensor
of low outside temperatures, full
charging of the weaker battery is improved, and in case of summery temperatures unnecessary battery gassing will
be avoided.
This is highly recommended, if the battery is exposed to strong variations in temperature, such as in the motor
compartment.
Safety Regulations and Appropriate Application:
1.Charging of lead-gel, lead-AGM, lead-acid or LiFePO4 (with integrated BMS!) batteries of the indicated nominal voltage
and simultaneous supply of the consumers being connected to these batteries in fixed installed systems.
2.Solar panels up to the maximum power rating (Wp) of the used solar controller.
3.The indicated cable cross sections at the charging ports and at the panel input.
4.With fuses of the indicated capacity near the battery to protect the cabling between battery and charging ports.
5.Installation in a well-ventilated room, protected from rain, humidity, dust, aggressive battery gas, as well as in an
environment being free from condensation water
6.Except for the fuse, the unit is not equipped with parts, which can be replaced by the user. Always use replacement car
fuses of the indicated capacity!
7.Keep children away from the solar controller and the batteries.
MPPT
Dual battery
User Manual
MPPT5012A-DUO-BT
MPPT5025A-DUO-BT
Thank you very much for buying our product ,Please read
thoroughly before using the prouuct
,
Automatic adaptation of the charging voltage to the battery temperature. In case
solar controller

Advertisement

loading

Summary of Contents for OLYS MPPT5012A-DUO-BT

  • Page 1 MPPT Dual battery solar controller User Manual MPPT5012A-DUO-BT MPPT5025A-DUO-BT Thank you very much for buying our product ,Please read thoroughly before using the prouuct Description of Functions Increased MPP charging current compared with conventional controllers, due to ultramodern controller technology (microprocessor) by 10 % to 30 % (efficiency >...
  • Page 2: Connection Plan

    Ⅱ Ⅰ START Total capacity of panel Main battery Vehicle Main motor battery Temperature chassis MPPT5012A-DUO-BT max.165W (option) Sensor MPPT5025A-DUO-BT max. 350W main battery (option) Batter y selection Battery type 1 2 3 4 ↑ ↑ Lead Acid ↑...
  • Page 3 1.) Main Battery “MAIN I” (must be connected): ○Connect the battery connections of the controller - (Minus) and + (Plus) to the 12 V main battery, observing the correct polarity and the cross section of the cables (refer to connection plan). ○Never operate the controller without the battery “Main I”...
  • Page 4: Pilot Lamps

    Battery has been charged almost fully. Solar controller is still in the charging constant voltage If it is flashing, frequency: 1time/s : controller over-heat frequency: 2times/s: battery over-voltage. or PV over-voltage "Charge" (only MPPT5012A-DUO-BT, green):  If it is lighting: Charging  Off: Solar power is insufficient.
  • Page 5  Partially Discharged Batteries: In contrast to other battery types, batteries on lead basis do not have any harmful memory effect. Consequently: In case of doubt, partially discharged batteries have to be charged fully as soon as possible. Always store only fully charged lead batteries. Recharge them periodically, particularly in case of used (older) batteries and higher temperatures.
  • Page 6: Technical Data

    Technical Data: MPPT5012A-DUO-BT MPPT5025A-DUO-BT Capacity of Solar Module (recommended / max.): 50 - 165 Wp 50 - 350 Wp Current Solar Module: 0 - 10 A 0 - 21.0 A Voltage Solar Module (Voc): max. 50 V max. 50 V...
  • Page 7: App Operation

    6. you can see the parameter after 3 -5 second from APP 7. The distance between phone and bluetooth is 10 meters. if no signal, reconnect the device SHENZHEN OLYS COMPANY LIMITED Addr: 5 floor, B building of Sheng De Industrial Park, Lang Kou, Da Lang,...

This manual is also suitable for:

Mppt5025a-duo-bt