Download Print this page
Blueprint CGLP-2 Quick Start Manual

Blueprint CGLP-2 Quick Start Manual

Co2 generator

Advertisement

Quick Links

Blueprint
Controllers put the power of automation to work in garden environments everywhere. For safety and optimal performance,
®
please carefully read this document in full before installing and operating this Blueprint
Features
• Two, four, eight or ten preinstalled liquid propane or natural gas burners
• Electronic ignition provides reliable starts
• Dual solenoid valves eliminate open pilot fl ame
24-VDC power supply
Specifi cations
Liquid Propane (LP)
Max. Area
Size (Cu Ft)
CGLP-2
2,000
CGLP-4
4,000
CGLP-4H
4,000
CGLP-8
8,000
CGLP-8H
8,000
CGLP-10
10,000
Natural Gas (NG)
Max. Area
Size (Cu Ft)
CGNG-2
2,000
CGNG-4
4,000
CGNG-4H
4,000
CGNG-8
8,000
CGNG-8H
8,000
CGNG-10
10,000
Hardware
Max. CO
BTU Rating
2
(Cu Ft/Hr)
5.3
2,263-4,526
10.6
2,263-9,052
8.4
1,788-7,152
21.2
2,263-18,104
16.7
1,788-14,304
26.5
2,263-22,630
Max. CO
BTU Rating
2
(Cu Ft/Hr)
5.4
2,767-5,534
10.8
2,767-11,068
9.6
2,455-9,820
21.6
2,767-22,136
19.2
2,455-19,640
27.7
2,767-27,670
• Includes gas regulator, 12' hose and hanging hardware
• Built-in safety tip-over switch
• Three-year warranty
Natural gas hose
with regulator
Variable Output
Gas Pressure
1-2 burners
1-4 burners
1-4 burners
11" WC/2.8 kPa
1-8 burners
1-8 burners
1-10 burners
Variable Output
Gas Pressure
1-2 burners
1-4 burners
1-4 burners
4.5" WC/1.15 kPa
1-8 burners
1-8 burners
1-10 burners
CO
Generator.
®
2
Liquid propane hose
with regulator
Power
Dimensions
Requirements
9" x 10" x 18"
15" x 8.5" x 18"
15" x 8.5" x 18"
400 mA @ 24-VDC
15" x 9.8" x 18"
15" x 9.8" x 18"
15" x 9.8" x 18"
Power
Dimensions
Requirements
9" x 10" x 18"
15" x 8.5" x 18"
15" x 8.5" x 18"
400 mA @ 24-VDC
15" x 9.8" x 18"
15" x 9.8" x 18"
15" x 9.8" x 18"
rev:92014

Advertisement

loading

Summary of Contents for Blueprint CGLP-2

  • Page 1 Blueprint Controllers put the power of automation to work in garden environments everywhere. For safety and optimal performance, ® please carefully read this document in full before installing and operating this Blueprint Generator. ® Features • Two, four, eight or ten preinstalled liquid propane or natural gas burners • Includes gas regulator, 12’ hose and hanging hardware • Electronic ignition provides reliable starts • Built-in safety tip-over switch...
  • Page 2 Warning • Failure to read and understand these instructions before installing or operating this product could result in personal injury or property damage. • Installation and connection of gas lines must be completed in compliance with local and national regulations. • Do not store gasoline or other flammable gases or liquids near the unit. • Keep objects away from the Generator as the electrodes produce sparks. • Install the Generator in an adequately ventilated area. Without adequate ventilation, CO can reach toxic levels. Levels above 2500 ppm can cause headaches and other symptoms, and levels above 5000 ppm are toxic. • Do not use the standard Generator at altitudes higher than 4,500 ft above sea level if the burners are producing yellow flame. • The Generator is designed to be operated only while hanging. Do not operate the Generator on a table or other surface because the unit requires unrestricted airflow through the bottom of the unit. • Do not turn on the Generator without reading the “Start-up Procedure” section. Installation 1. Use the provided hardware to securely hang the Generator from an overhead support, such as a ceiling beam. Leave at least 20” between the unit and the wall, ceiling, or other surfaces or objects. Install the screw hooks into the overhead support, then use the S hooks to attach the chain to the unit and the screw hooks. Bend the S hooks to secure the chain.
  • Page 3 Modifying CO Output It is strongly recommended to use a controller or timing device to properly manage the output of the Generator. If this is not possible, the Generator’s CO and heat output can be modified by using the provided brass pipe plugs to reduce the number of active burners. Additional plugs may be purchased separately. The Specifications table shows the size of the growing area that is appropriate for each model as well as how much CO and heat are produced at maximum capacity. Each burner replaced with a brass pipe plug will reduce the Generator’s output by 2.65 cu ft/hr of CO and 2,263 BTU for a standard liquid propane unit, 2.7 cu ft/hr of CO and 2,767 BTU for a standard natural gas unit, 2.1 cu ft/hr of CO 1,788 BTU for a high altitude liquid propane unit, and 2.4 cu ft/hr of CO and 2,455 BTU for a high altitude natural gas unit. The CGLP-10 and CGNG-10 feature the ability to vary CO output with the flip of a switch. The main power switch activates the two burners nearest the electrodes, and two additional selector switches independently activate two separate banks of four burners each. Brass pipe plugs are also provided for further modification. To determine the appropriate number of burners to activate for the growing area, divide the size of the growing area (in cubic feet) by 1,000. For example: Activate six burners in a growing area of 6,000 cu ft.
  • Page 4 Blueprint Generator Limited Warranty ® What This Warranty Covers This warranty covers defects in materials and workmanship under normal use, with any exceptions listed below. Who This Warranty Covers This warranty applies to the original purchaser of this product with the original proof of purchase. How Long Warranty Coverage Lasts This warranty is in effect for a period of three years from the original date of purchase. What This Warranty Does Not Cover This warranty does not cover damage or defects resulting from the improper installation, alteration, abuse, accidental damage, unauthorized repair or misuse of this product. Misuse includes but is not limited to outdoor use. This warranty does not apply to cosmetic defects or other defects that do not affect the functionality of the product, and is void if the product has been damaged as a result of fire, flood, or other natural disaster. Sunleaves Garden Products (“Sunleaves”) shall not be responsible for any incidental or consequential damages of any nature, including damage or injury caused to other products, machinery, buildings or property; loss of profits, time or product; or inconvenience.This warranty is given in lieu of all other warranties, express or implied, including without limitation merchantability and fitness for a particular purpose. Some states do not allow the exclusion or limitation of incidental and consequential damages, or limitations on how long an implied warranty lasts, so the above limitation(s) may not apply to you. What Sunleaves Will Do If Sunleaves determines the warranted product is defective in material or workmanship during the warranty period, then Sunleaves, at its option, will either repair or replace the product. In no event shall the cost of repair or replacement exceed the original purchase price. How to Obtain Warranty Service Return this product along with the original proof of purchase to the place of purchase in accordance with store policy. The original proof of purchase MUST accompany the Blueprint product for this warranty to be valid. ® How State Law Applies This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. For technical support and warranty information, call toll-free 888-464-9676 or email info@sunleaves.com. rev:92014...

This manual is also suitable for:

Cglp-4Cglp-4hCglp-8Cglp-8hCglp-10Cgng-2 ... Show all