Download Print this page
LITEWAY LuxLink IRGT-1001 Operating Instructions

LITEWAY LuxLink IRGT-1001 Operating Instructions

Fiber optic modulated irig transmission systems

Advertisement

Quick Links

WARRANTY
All fiber optic transmission systems, products and accessories
manufactured by Liteway, Inc. and it's subsidiaries are fully
tested prior to shipment and are warranted against defective
materials and workmanship for a period of five full years from the
date of the original shipment. Should a problem occur, a Return
Material Authorization Number (RMA) must be obtained from
Liteway Inc. at (516) 931-2800 and the item returned to Liteway,
Inc. 166 Haverford Road, Hicksville, NY 11801, USA, prepaid.
Liteway Inc. will then, at its option repair or replace the defective
item.
Liteway, Inc. maximum liability under this warranty is limited to
the cost of the defective item only. No contingent liabilities of
any kind are either assumed or implied.
Any items returned to Liteway, Inc. that have been misused,
abused, damaged, modified, connected or adjusted in any way
contrary to the instructions furnished by Liteway, Inc. or repaired
by unauthorized personnel will not be covered by this warranty.
Any non-warranty repairs required will be quoted at the current
rate for such services.
!
Important Notices
CAUTION !
AVOID DIRECT EXPOSURE TO BEAM.
All -7, -8, and -9 Models use laser diodes. These solid-state laser
diodes are located in the optical ports of these units. Laser
diodes produce invisible radiation that may be harmful to human
eyes. Never look directly into the optical port of any fiber optic
unit designed to operate with single-mode optical fiber.
NOT FOR LIFE SUPPORT SYSTEMS
Liteway, Inc. does not authorize or warrant any of its products or
accessories for use in critical life support systems or applications
of any kind.
© Copyright 2017 Liteway, Inc.
106630 Rev G
OPERATING INSTRUCTIONS
®
LuxLink
Fiber Optic Modulated IRIG
Transmission System
Models;
IRGT-1001, IRGR-1001
The IRGT / IRGR-1001 system consists of the IRGT-1001
transmitter and IRGR-1001 receiver and will transmit modulated
IRIG signals from one point to another.
Technical Specifications
Signal Bandwidth
500 KHz
In/Out Impedance
600 ohms
In/Out Signal Level
3 volt peak to peak (5 mA)
Protocols
IRIG A,B,D,E,H; NASA36, IEEE-1344
Signal/Noise Ratio
60 dB/min (ref 1Vpp)
Linearity & THD
3% max
Operating Wavelength
850(-1),1310(-3,-7),1550(-9)
Optical Loss Budget
0 – 12 dB
Fibers Accommodated
1 multimode(-1,-3),1 single-mode(-7,-9)
Temperature Range
-35º to +75ºC
Power Requirements
11-24 VAC/DC @150 mA
Physical Size (mm)
5.0"(127)L x 1.0" (25.4)W x 3.0"(7)D
System Delays
see table at end of manual
All specifications measured with 1Km of 62.5u multimode fiber.
All specifications are subject to change without prior notice.

Advertisement

loading

Summary of Contents for LITEWAY LuxLink IRGT-1001

  • Page 1 Models; Liteway Inc. at (516) 931-2800 and the item returned to Liteway, Inc. 166 Haverford Road, Hicksville, NY 11801, USA, prepaid. Liteway Inc. will then, at its option repair or replace the defective IRGT-1001, IRGR-1001 item. Liteway, Inc. maximum liability under this warranty is limited to the cost of the defective item only.
  • Page 2 Installation Instructions Indicator Lights Indicator Lights when The diagram below shows the typical installation of the IRGT-1001 Proper power is present. and IRGR-1001 fiber optic IRIG transmission units. Both should be The loss of sig alarm is activated and there is no connected exactly as shown and an IRIG signal applied to the Alrm video present...

This manual is also suitable for:

Luxlink irgr-1001