SERIES
INTRODUCTIONS
1. Snap-in mounting type to reduce labor cost.
Compact and reliable at low cost.
2. Bleeder resistor can be added with suffix "-R"
on part numbers,except G3H,G3V,W3V,G3J,W3J,types.
3. Bleeder resistor can be added with suffix "-R" on part numbers.
4. Optional side snap-in mounting clip type with suffix (H) on part
numbers.
5
. All part numbers are UL recongnized, CSA certified and VDE
approved.
6. With optional Y-Cap from 100pF to 3300pF .
COMPONENTS
PART NO.
Cx (uF)
01GENG3E/W3E/-R
03GENG3E/W3E/-R
03GENW3ES/-R
03GENG3Q/W3Q/-R
06GENG3E/W3E/-R
06GENG3Q/W3Q/-R
0.1
06GENW3ES/-R
10GENG3E/W3E/-R
10GENG3C/W3C/-R
*
10GENG3Q/W3Q/-R
10GENW3ES/-R
15GENG3E/W3E/-R
* *
20GENG3E/W3E/-R
* *
*
UL, CSA approved to 4A 115/250V
UL, CSA approved to 8A 115/250V
VDE approved to 8A/250V
MINIMUM INSERTION LOSS IN dB
COMMON MODE (L-G) IN 50 OHM SYSTEM
CURRENT
RATING
.15
.50
1A
28
35
3A
20
25
6A
12
18
6A (G3Q)
15
20
10A
4
10
10A (G3C)
10
15
10A (G3Q)
10
12
15A
4
10
20A
8
10
ELECTRICAL SCHEMATIC
L
L
R
Cx
I
N
E
N
G
R: 1M /-R ONLY
SNAP-IN MOUNTING HIGH PERFOR-
MANCE IEC CONNECTOR FILTERS
L (mH)
Cy (pF)
R ( )
6.5
2.5
2.5
4
0.8
1.5
2200
1M
0.8
0.2
0.4
0.3
0.2
0.2
0.3
UL, CSA approved to 13A 115/250V
*
VDE approved to 10A/250V
* *
VDE approved to 16A/250V
*
* *
FREQUENCY-MHz
1.0
5.0
10
30
38
38
40
40
30
38
40
40
24
35
40
40
24
35
40
55
13
28
35
40
15
25
30
35
15
30
32
45
13
28
35
40
15
25
30
35
L'
L
Cy
O
A
Cy
D
N'
G'
SPECIFICATIONS
1. Maximum leakage current each
line-to-ground @ 115VAC 60Hz: 0.2mA
@ 250VAC 50Hz: 0.4mA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250VAC
INSERTION LOSS (TYPICAL)
03GENG3E
COMMON MODE
06GENG3E
COMMON MODE
80 dB
60 dB
40 dB
20 dB
0 dB
100K
10K
20GENG3E
COMMON MODE
80 dB
60 dB
40 dB
20 dB
0 dB
10K
100K
2-7
V
D
E
DIFF. MODE
DIFF. MODE
1M
10M
DIFF.MODE
1M