Quick Links

15036 with 36 LED, 15136 with 36 LED,
16036 with 36 LED, 16136 with 36 LED
EMERGENCY LIGHTING ARMATURES
USAGE AREAS
• At the hospitals, flats, houses
• At the schools
• At the supermarkets, shops and covered markets
• At the stations, terminals, airports and ports
GENERAL SECURITY CAUTIONS
• Take out the product from orginal package and control if there is any damage of transportation and
general view of the product
• Don't use the product for out of purpose
• Keep away from the wather and moist areas
• Keep away from dust and dirt
• Protect from impact
• Turn off the power before starting to install
• For whole charging hold the battery in charge 22 hours continuous
• Only authorized technicians must install the device
• Only 1.2 V rechargable batteries must be used, otherwise dive is broken
• Leave the battery recycling places after using
CAUTIONS FOR HUMAN HEALTH AND ENVIRONMENT
• Do not try to repair the product by yourself
• Keep away from stove, radiator or any heating device, do not expose to direct sunlight.
• Don't try to mend product by opening the cover, call to our free call center.
INFORMATIONS REGARDIN WRONG USAGE
• Follow installation instructions as described in instruction manual, otherwise product is out of guarantee.
• Keep the product away from dust, moisture, impact, fluid during the use. The product gets out of
guarantee if product defects occur as a result of those mentioned matters.
INFROMATIONS REGARDING MAINTENANCE AND CLEANING THAT CAN BE DONE BY USER
• When happens any defect you can get assistance from expert or our free call center.
• Rechargable battery must be durable and must be changed periodicaly depending on using duration
Before changing batteries power must be cut. Battery compartment was shown in the figure 3 and 6.
PERIODICAL MAINTENANCE
• To extend life of batteries , batteries should be discharged in every 20 days.
• Attendant of building should turn off the power, and wait for discharging of batteries
RULES FOR MAINTENANCE AND USAGE
• When device gets dirty should be cleaned with a dry cloth.
• Keep the product away from dust,moisture, impact, fluid during the use. The product gets out of
guarantee if product defects occur as a result of those mentioned matters.
• When any defect happens, you must get assistance from an expert or our free call center.
• Rechargable battery must be durable and must be changed periodicaly depending on using duration
Before changing batteries power must be cut. Battery compartment was showed in the figure 3 and 6.
• Keep the original package, invoice, etc to use when its necesary.
RULES FOR MOVING AND TRANSPORT
• Should be carefull when transporting , Shouldn't put heavy goods on products, should be protected
from impact,dust,fluid.
BASIC INFORMATION ABOUT PRODUCT FEATURES
• Meets all necessities in the emergency lighting and directing solutions ,emergency lightings provides
the emergency security and prevents the panic in emergency.
• Plain , stylish , quick mounting, easy maintenance.
• Lights automatically when power cut and other type can light continuous and when power cut.
• 130 lumen intensity of illumination at the emergency
• 3 hours continuous lighting
• Two colored LED shows state of battery, if charge is under 2,9 V lights red otherwise green
• Spends less energy with LED
• The product lifescycle: 10 years.
TECHNICAL FEATURES
Operating voltage
~230-240 V / 50-60 Hz.
Battery type
3 units 1.2V 2100 mAH AA Ni-Mh rechargeable battery
Operating battery time
3 hours
Charging time
22 hours
Operating mode
non-maintened (15036 with 36 LED - 16036 with 36 LED)
maintened (15136 with 36 LED - 16136 with 36 LED)
Protection class
IP 20
Operating/Ambient temperature
-20 °C ~ +40 °C
Radiated Luminary(1 meter)
130 lumen
Producer Company, Service station and spare parts suppling address:
Na-de Elektronik Sanayi ve Ticaret A.fi. ‹stanbul Deri Organize Sanayi Bölgesi 12. Yol M1-8 Parsel
34953 Tuzla /‹stanbul TÜRK‹YE Tel.:+90 (216) 394 01 55 -56 • +90 (216) 394 05 30 Fax: +90 (216) 394 01 64
info@na-de.com.tr • www.na-de.com.tr
INSTRUCTION MANUAL
• At the spare foundations places of worship and
sport complex
• At the museums and exhibition galleries.
• At the accommodetions for travelers and
restaurants
• At the place of amusement
class II
TS EN 60598-1
TS EN 60598-2-22
Complies with ROHS Regulation Directive
2002/95/EC
MOUNTING
MODEL : 15036 with 36 LED, 15136 with 36 LED
Remove the plastic screw
cover with the screw driver
and take off the behind screws
release the surface mount
aparate from the device.
FIGURE-1
FIGURE-2
Screw the device in a
surface mount aparate
after that fix the plastic
screw cover to the place
FIGURE-3
MOUNTING
MODEL : 16036 with 36 LED, 16136 with 36 LED
Remove the plastic screw
cover with the screw driver.
FIGURE-4
Mount the device with 2 screws
on the wall or ceiling.
FIGURE-5
Fix the plastic screw cover
to the places
FIGURE-6
ELECTRICAL CONNECTION OF THE DEVICE
Batteries are out of warranty
KK-15036xxx 140109_EN-00
R
TÜVRheinland
AN 60041383 0001
27111002 002
Fix the surface mount
aparate on the wall.
Battery
socket
Battery socket
N :Notr
L : Line (Phase)
FIGURE-7

Advertisement

loading

Summary of Contents for NA-DE 15036

  • Page 1 Batteries are out of warranty Na-de Elektronik Sanayi ve Ticaret A.fi. ‹stanbul Deri Organize Sanayi Bölgesi 12. Yol M1-8 Parsel 34953 Tuzla /‹stanbul TÜRK‹YE Tel.:+90 (216) 394 01 55 -56 • +90 (216) 394 05 30 Fax: +90 (216) 394 01 64 info@na-de.com.tr •...
  • Page 2 ‹malatc› Firma, Servis ‹stasyonu ve Yedek Parça Temin Adresi: Piller garanti kapsam› d›fl›ndad›r. Na-de Elektronik Sanayi ve Ticaret A.fi. ‹stanbul Deri Organize Sanayi Bölgesi 12. Yol M1-8 Parsel 34953 Tuzla /‹stanbul TÜRK‹YE Tel.:(0216) 394 01 55 -56 • (0216) 394 05 30 Fax: (0216) 394 01 64 Daha fazla bilgi için: 0 800 261 78 05 no’lu ücretsiz danıflma hattımızı...
  • Page 3 TÜVRheinland TS EN 60598-1 AN 60041383 0001 TS EN 60598-2-22 27111002 002 130 Lm ~85-265B / 50-60 130 lm A.fi. info@na-de.com.tr • www.na-de.com.tr KK-15036xxx 121114_RUS-00...

This manual is also suitable for:

16036