Download Print this page
LMI Milton Roy Micropace MP-100 Instruction Sheet

LMI Milton Roy Micropace MP-100 Instruction Sheet

Electronic metering control modules

Advertisement

Quick Links

(866) 433-6682 • (281) 359-8538 • sales@novatech-usa.com • www.novatech-usa.com
Micropace™ Electronic Metering Control Modules
Specifications and dimensions shown above are typical for all models.
MP-100 Analog to Digital Converter
Input Signal Source: 4-20 mA (isolated) only.
Max Input Voltage: 42VDC
Impedance: 100 Ohms
INSTALLATION
1.
Disconnect signal source supply voltage prior to
connecting your MP-100. Failure to do so may damage
the MP-100 circuit.
2.
Insert the 4-pin connector into the socket on your LMI
Series A7, B7 or C7 Metering Pump. The socket is
located on the bottom right under the pump control
panel.
3.
Connect the other end of the cable to your input
signal source. Polarity is:
white = positive(+); black = negative (-).
LIQUID METRONICS DIVISION
MICROPACE
®
MP-100 Series Loop Control
Instruction
Power Supply:
Ambient Temperature:
Enclosure:
Percent
Pump
Speed
4
6
8 10 12 14 16 18 20
milliAmp DC Signal
MP-100 Adjustment Range
LIQUID METRONICS DIVISION
MICROPACE
4 DIGIT MULTIPLIER
MODEL MP-500M
MP-100 Typical Installation
http:\\www.lmipumps.com
Sheet
15 VDC, Supplied by
LMI pump
0
0
0
F to 140
F
(-20
0
C to 60
0
C)
Splash & dust proof,
IP-65 rated
Span (range)
adjustment by
stroke length
8 Post Office Square
Acton, MA 01820 USA
TEL: (978) 263-9800
FAX: (978) 264-9172
Replaces same of Rev. B 7/97
1631.C 7/99

Advertisement

loading

Summary of Contents for LMI Milton Roy Micropace MP-100

  • Page 1 MP-100. Failure to do so may damage MP-100 Adjustment Range the MP-100 circuit. Insert the 4-pin connector into the socket on your LMI Series A7, B7 or C7 Metering Pump. The socket is located on the bottom right under the pump control panel.
  • Page 2 Replace the cover and the four screws. Insert the 4-pin connector into the socket on your LMI Series A7, B7 or C7 Metering Pump. The socket is located on the bottom right under the pump control panel.

This manual is also suitable for:

Milton roy micropace mp-400dMilton roy micropace mp-500m