Download Print this page

Bryan Boilers DTA-100 Specification Sheet

Bryan boilers boiler feedwater deaerators specification sheet

Advertisement

Quick Links

TM
Separable Tank Tray Type Boiler Feedwater Deaerators
Capacities 70,000 to 300,000 PPH (2030 to 8695 BHP)
175,000 PPH
unit shown
The Bryan tray type deaerator is unsurpassed in
performance and reliability. These units are
ASME Code pressurized units, and are guaran-
teed to deliver deaerated water at a maximum
oxygen content of .005cc/l (7PPB) and zero
measurable CO
. All internal surfaces that
2
come in contact with undeaerated water are
constructed of type 304L stainless steel for long
life and low maintenance. Their long residence
time makes them readily adaptable to all
systems, even where wide load swings occur.
A complete line of boiler feedpump and
control packages is available making the Bryan
tray deaerator a completely packaged unit
ready for installation with the minimum amount
of field assembly.
BRYAN STEAM
Performance Features
• Oxygen removal to .005 cc/l (7 PPB)
• CO
removal to 0% measurable
2
• Reduce chemical costs
• Reduce boiler and system corrosion
• Pre-heat boiler feedwater
• Improve boiler efficiency
• Quick equipment payback, compared
to chemical oxygen removal
Construction Features
• Constructed to ASME Section VIII,
Division I for 50 PSIG
• Hinged tray access door
• Standard 10 minutes deaerated water storage
• Easily accessible manway in storage tank
• All internal surfaces that contact
undeaerated water are constructed of type
304L stainless steel
• Internal direct contact vent condenser
for minimum steam loss
• Structural steel stand/pump platform
• 2-stage deaeration
• Available as completely packaged unit
including pumps and control panel
Tray
Access
Door
Non-Condensable Gases (O , Co )
2
2
Deaerated Water
Steam
Condensate Return
and Water Make-up
Deaerator Outlet
to Storage Tank
Form No. 6440
(5/00)
Stainless Steel Vent Pipe
Vented to Atmosphere
Stainless Steel
Internal Vent Condenser
Stainless Steel
Spray Tube
Welded Stainless
Steel Trays
Stainless Steel
Tray Chamber

Advertisement

loading

Summary of Contents for Bryan Boilers DTA-100

  • Page 1 BRYAN STEAM Separable Tank Tray Type Boiler Feedwater Deaerators Capacities 70,000 to 300,000 PPH (2030 to 8695 BHP) 175,000 PPH unit shown The Bryan tray type deaerator is unsurpassed in performance and reliability. These units are ASME Code pressurized units, and are guaran- teed to deliver deaerated water at a maximum oxygen content of .005cc/l (7PPB) and zero...
  • Page 2: Specifications

    Boiler hp (kg/h) (kW) 70,000 2,029 DTA-70 (31,752) (19,911) 80,000 2,319 DTA-80 (36,288) (22,756) 90,000 2,609 DTA-90 (40,824) (25,600) 100,000 2,899 DTA-100 (45,360) (28,445) 125,000 3,623 DTA-125 (56,700) (36,556) 150,000 4,348 DTA-150 (68,040) (42,667) 175,000 5,072 DTA-175 (79,380) (49,779) 200,000 5,797...

This manual is also suitable for:

Dta-125Dta-150Dta-175Dta-200Dta-250Dta-300 ... Show all