Mechanical water heater time switch

Advertisement

Available languages

Available languages

Quick Links

MECHANICAL
WATER HEATER
TIME SWITCH
15146
SWITCH:
CONTACT RATINGS:
TIMING MOTOR:
POWER CONSUMPTION: 3 WATTS MAX
Typical Wiring Diagram,
240 VAC Application
208-277VAC/60Hz
We recommend that installation be made by a licensed electrician.
Disconnect power at main panel prior to installing or servicing this
time switch or the equipment connected to it.
Connect in accordance with national and local electrical codes.
Supply Connections: Use gauge specified (AWG #8-14 ) suitable for 75
(167
F). Replace insulator before turning on electricity to unit.
º
INSTALLATION AND OPERATING INSTRUCTIONS
TO SET ON AND OFF TIMES:
trippers turn ON. Dark trippers turn
OFF. Place tripper on dial edge as
shown in figure and set point of each
tripper to desired operating time.
Note if selected time is AM or PM. Hold
tripper against dial edge and firmly
tighten knurled screw.
INSTALLATION AND OPERATING
INSTRUCTIONS TO SET DIAL TO TIME:
Turn dial counter-clockwise until correct
time is indicated by arrow on nameplate.
FOR TEMPORARY MANUAL OVERRIDE:
Press down external lever on the right to turn
timer ON. Press external lever up to turn timer
OFF. CAUTION: Do not rotate dial for manual override.
TO REMOVE MECHANISM FROM CASE:
Press lever near case latch to release mainplate and swing the
movement out. To replace, insert mainplate projections in slots
opposite latch and swing movement in until it latches.
15146
MANUAL VERSION 1
03/25/11
WWW.JASCOPRODUCTS.COM
24 HOUR TIME SWITCH
DPST
40 AMP 250V
208-277VAC 60Hz
Light
10,00VA WATTS 250V
Dial Calibrations
Knurled Screw
OFF TIME
(Dark Tripper)
O
F
F
GREEN=OFF
RED=ON
LOAD
C
º
ON TIME
(Light Tripper)
O
N
OFF GREEN
EXTERNAL
OVERRIDE
SWITCH
ON RED
GE5362-41K2

Advertisement

loading

Summary of Contents for Jasco GE5362-41K2

  • Page 1 TO REMOVE MECHANISM FROM CASE: Press lever near case latch to release mainplate and swing the movement out. To replace, insert mainplate projections in slots opposite latch and swing movement in until it latches. 15146 MANUAL VERSION 1 03/25/11 WWW.JASCOPRODUCTS.COM GE5362-41K2...
  • Page 2 • 15146 MINUTERIE POUR CHAUFFE-EAU INTERRUPTEUR: bipolaire unidirectionnels CAPACITÉ DES CONTACTS: 40 A 250 V 10,000 WATTS 250 V MOTEUR DE MINUTAGE: 208-277 V c.a. 60 Hz CONSOMMATION: 3 WATTS MAX Schéma de câblage classique, utilisation de 240 V c.a. CHARGE 208-277 V c.a 60Hz Nous recommandons de confier l’installation à...
  • Page 3 • INTERRUPTOR DE HORA PARA 15146 CALENTADOR DE AGUA INTERRUPTOR: BIPOLAR (DPST) CLASIFICACIONES DEL CONTACTO: 40 A 250 V 10,000 VATIOS 250 V MOTOR DEL TEMPORIZADOR: 208-277 V c.a. 60 Hz CONSUMO DE ENERGÍ: 3 VATIOS MÁX. Diagrama de cableado típico, aplicación a 240 VCA CARGA 208-277 V ~ 60Hz...

This manual is also suitable for:

15146