Thermo Pride AOPS7488 Instructions Manual

Concentric vent / combustion air kit

Advertisement

Quick Links

ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL.
CONCENTRIC VENT / COMBUSTION AIR KIT FOR
SIDEWALL OR VERTICAL VENTING APPLICATIONS
ELECTRIC SHOCK HAZARD/FIRE AND/OR EXPLOSION HAZARD.
Failure to carefully read and follow all instructions in these instructions could result in death,
personal injury, property damage and/or furnace malfunction.
Installation or repairs made by unqualified persons could result in hazards to you and others.
Installation MUST conform with local codes or, in the absence of local codes, with codes of the
country having jurisdiction.
The information contained in these instructions is intended for use by a qualified service
technician familiar with safety procedures and equipped with the proper tools and test
instruments.
ELECTRIC SHOCK HAZARD/FIRE AND/OR EXPLOSION HAZARD.
Failure to follow this warning could result in death, personal injury, property damage and/or
equipment damage.
Turn OFF gas supply at manual gas valve before turning OFF electric power supply and
starting installation.
Turn OFF electric power supply at disconnect switch or service panel before starting
installation.
CARBON MONOXIDE POISONING, AND PROPERTY DAMAGE HAZARD.
Failure to follow this warning could result in death, personal injury, property damage and/or
equipment damage.
This kit is to be used for terminating condensing Category IV vent furnaces. DO NOT use kit
to terminate Category I, II, or III vent furnaces.
MG-510
ECN 5102-MA 091216
- 1 -

Advertisement

loading

Summary of Contents for Thermo Pride AOPS7488

  • Page 1 ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. CONCENTRIC VENT / COMBUSTION AIR KIT FOR SIDEWALL OR VERTICAL VENTING APPLICATIONS ELECTRIC SHOCK HAZARD/FIRE AND/OR EXPLOSION HAZARD. Failure to carefully read and follow all instructions in these instructions could result in death, personal injury, property damage and/or furnace malfunction.
  • Page 2 The following parts are included in the termination kit. ITEM DESCRIPTION AOPS7488 2” KIT AOPS7489 3” KIT 2” Rain Cap 3” Rain Cap 3" dia x 19-1/2” long, SDR-26 pipe 4"...
  • Page 3 C) wind effects that may cause recirculation of flue products, debris or light snow and D) visible vent vapor. 3. Cut one 4” diameter hole through the structure for the AOPS7488 kit or one 5” diameter hole for the AOPS7489 kit.
  • Page 4: Horizontal Termination

    ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. VERETICAL TERMINATION HORIZONTAL TERMINATION...
  • Page 5 ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. 2” CONCENTRIC VENT KIT (AOPS7488)
  • Page 6 ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. 3” CONCENTRIC VENT KIT (AOPS7489)
  • Page 7 ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. 5. Partially assemble the concentric vent termination kit. Clean and cement the parts using the procedures for Joining Pipe and Fittings section of the furnace installation manual. A) Cement the wye fitting to the larger diameter outer pipe. (see Fig-5) B) Cement the rain cap to the smaller diameter inner pipe.
  • Page 8 ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. CARBON MONOXIDE POISONING, FIRE AND EXPLOSION HAZARD. Failure to follow this warning could result in death, personal injury and/or property damage. Do not operate the furnace with the rain cap removed as recirculation of the flue gases may occur.

This manual is also suitable for:

Aops7489