Negele vnv-e Product Information

Negele vnv-e Product Information

External level switches for conductive level sensors

Advertisement

Quick Links

Product Information
External Level Switches for
Conductive Level Sensors
Application
• level detection of fluid and conductive media in vessels
(min. conductivity 1µS/cm but depending on the level switch)
Application Examples
• full- / empty detection in vessels and pipes
• level control in vessels
• overfill protection in vessels
• dry running protection in pipes (e.g. pump protection)
Features
• measurement signal free of DC-voltage
• only one level switch for up to 5 sensors
• CE-lable
Options / Accessories
• high sensitive version up to 1MOhm available
• version with wire-loop-control available
Version with 24VDC output; Power Supply 24VDC
Type
Sensitivity
0,1...100kOhm
vnv-e
vnv-d
0,1...100kOhm
vnv-du
0,1...100kOhm
0,1...10KOhm
znv-z
0,1...100kOhm
vnv-v
0,1...100kOhm
Version with relay output; Power Supply 230VAC (Option: 115VAC, 24VAC)
Type
Sensitivity
vnv-s
0,1...100kOhm
vnv-sd
0,1...50kOhm
vnv-wev
0,1...100kOhm
vnv-wevh
0,1...1MOhm
vnv-wd
0,1...100kOhm
vnv-wdh
0,1...1MOhm
vnv-w
50kOhm fest
Explanation considering the vnv-wd:
* Level detection: The output is switched as soon as the electrode EO2 gets contact to the medium. It's switched off again when the
electrode looses contact to the medium.
** Level control: The output is switched on as soon as EU1 looses contact to the medium. It keeps switched on until the electrode EO1
gets contact. When EO1 gets contact, the output is switched off and keeps switched off until EU1 looses contact to the medium again. If
you only use M and EO1 of the level control, it works like a level detection.
Order Code
version with 24VDC power supply
(no further options)
vnv-e
vnv-d
vnv-du
vnv-v
znv-z
Negele Industrieelektronik GmbH & Co.KG•Raiffeisenweg 7•D-87743 Egg a.d. Günz•Tel. +49(0)8333/9204-0•Fax +49(0)8333/9204-49
vnv-e
Function
1 level control**; switch-on / off delay time adjustable (1...10sec.)
1 level control** and 1 level detection*
switch-on / off delay time adjustable (1...10sec.)
1 level control** and 1 level detection*
switchable sensitivity
2 level detection*
4 level detection*
Function
1 level control**
1 level control**
1 level control**; switch-on / off delay time adjustable (1...10sec.)
1 level control**; switch-on / off delay time adjustable (1...10sec.)
1 level control** and 1 level detection*
1 level control** and 1 level detection*
1 level detection*
version with AC
high sensitive
power supply
version
(up to 1MOhm)
vnv-s
.n standard*
vnv-wev
.h high sensitive
vnv-wd
vnv-w
not possible
vnv-sd
Order example:
vnv-wev.h / 230VAC
vnv-e, -d, -du, -v, znv-z
vnv-d
vnv-s
vnv-wev
power supply
230VAC
115VAC
42VAC
24VAC
vnv-s, -wev, -wd
znv-z
vnv-v
vnv-wd
vnv-wd
* Standard:
no declaration
necessary

Advertisement

loading

Summary of Contents for Negele vnv-e

  • Page 1 .n standard* 230VAC * Standard: vnv-d vnv-wev .h high sensitive 115VAC no declaration vnv-du vnv-wd 42VAC necessary vnv-v 24VAC vnv-w not possible znv-z vnv-sd Order example: vnv-wev.h / 230VAC Negele Industrieelektronik GmbH & Co.KG•Raiffeisenweg 7•D-87743 Egg a.d. Günz•Tel. +49(0)8333/9204-0•Fax +49(0)8333/9204-49...
  • Page 2 Switch-on and Switch-off delay can be adjusted independent of each other. switch S1 closed -> switch-on delay switch S2 closed -> switch-off delay switch S1+S2 closed ->switch-on and switch-off delay Negele Industrieelektronik GmbH & Co.KG•Raiffeisenweg 7•D-87743 Egg a.d. Günz•Tel. +49(0)8333/9204-0•Fax +49(0)8333/9204-49...
  • Page 3 When the medim reaches the maximum electrode (EO) the valve is closed again and the filling stops. Negele Industrieelektronik GmbH & Co.KG•Raiffeisenweg 7•D-87743 Egg a.d. Günz•Tel. +49(0)8333/9204-0•Fax +49(0)8333/9204-49...
  • Page 4 10bar 10bar 10bar NVS-166 Temperature Cleaning 140°C/30min 140°C/30min 140°C/30min Process 0...100°C 0...100°C 0...100°C NVS-345.2.b Compatible fitting EMK-032 EMZ-132 EMZ-352 07.04/Ka PM65 All data subject to change and errors excluded Negele Industrieelektronik GmbH & Co.KG•Raiffeisenweg 7•D-87743 Egg a.d. Günz•Tel. +49(0)8333/9204-0•Fax +49(0)8333/9204-49...

This manual is also suitable for:

Vnv-dVnv-duZnv-zVnv-vVnv-sVnv-sd ... Show all