Download Print this page

ACUVANCE FLEDGE 10.5T Instruction Manual

Sensor-controlled brushless motor

Advertisement

Quick Links

PRECAUTION FOR USE
•Before using this product, carefully read the important warnings described in this instruction
manual to understand the instructions thoroughly.
Instructions that the user must
DANGER
observe to prevent serious injury.
Instructions that the user must
WARNING
observe to prevent accidents.
•About installation
To prevent accident and fault:
DANGER
Conduct wiring work carefully. If a connecting part comes off under vibration
during travel, motor control may be disabled.
WARNING
To prevent accident and fault:
The soldering of each part must be conducted within 5 seconds.
Applying heat for a long period causes damage to the electronic components.
•About cable connections
To prevent accident and fault:
CAUTION
Make sure that the cables are properly connected. Do not connect the power supply
with reverse polarities. Be sure to insulate cable connection terminals. If the
connection terminals are short-circuited, it may result in damage to this product.
•About modification
To prevent smoke, fire and burns:
DANGER
Never attempt to solder the circuit board and electronic components in the motor.
•Handling precautions
To prevent smoke, fire and burns:
DANGER
During use of this product (when a power supply is connected to the motor, or
when the power switch is ON), keep watching the motor. If an abnormal condition
occurs, it may result in fire or other accident.
To prevent accident and fault:
CAUTION
Do not install this product in a place where water, oil, fuel or other conductive
liquids are present. Electronic components are vulnerable to minerals contained in
such liquids. If the product becomes wet with such liquids, immediately stop
operation, and dry it.
To prevent accident and fault:
CAUTION
Be sure not to use the motor in fully-throttled condition, if the motor is not
incorporated in a chassis drive unit. Running the motor at a high speed under no
load causes damage to the motor.
To prevent accident and fault:
CAUTION
If an improper gear ratio is selected, it results in motor overload, causing the motor
to be damaged by abnormal heating. Select an appropriate gear ratio carefully.
Technical Service Dept.
Useful information for handling
CAUTION
this product.
7F, Shin-Osaka Marubiru Annex 1-18-22
Higashinakajima Higashiyodogawa-ku
Osaka 533-0033 Japan.
www.acuvance.co.jp
E-mail support@acuvance.co.jp
Forced Air-cooled Motor
I N S T R U C T I O N
Sensor Controlled
Brushless Motor
Characteristic of FLEDGE
•Equipped with an innovative system
[A.V.S.] that realizes forced air cooling
inside the motor. This is the industry's
first feature.
This is an epoch-making structure
which some air holes are installed
at various locations inside the
A.V.S.
motor and the heat source in the
motor is directly cooled from the
end bell side.
•Equipped with heat reduction alloy plate
combined with vibration reduction
structure.
•Direct power terminal system with
integrated connector terminal and coil
connection plate. This improves power
transmission performance.
※FLEDGE is a motor dedicated to sensor-controlled brushless ESC. It is not applicable to sensorless ESC.
330300
M A N U A L
Thank you for purchasing the
ACUVANCE Sensor-Controlled
Brushless Motor.
This motor provides the best
performance when used in
combination with the ACUVANCE
brushless ESC. To obtain 100%
performance of this product, be
sure to read this instruction
manual. After reading this manual,
keep it carefully.
•Reduced motor weight, but still
high-rigidity.
•Inherits the AGILE original system [M.F.C.S]
Enables conversion to a
torque-type or High RPM-type by
changing only the magnetic force
M.F.C.S
with the same-shaped (volume
and weight) rotor.
•Compatible with functions [torque level /
torque end point] installed in XARVIS XX.
Please check our website or official
Twitter (@ACUVANCE_JAPAN) for
details on features and the latest
information.

Advertisement

loading

Summary of Contents for ACUVANCE FLEDGE 10.5T

  • Page 1 CAUTION performance when used in Make sure that the cables are properly connected. Do not connect the power supply combination with the ACUVANCE with reverse polarities. Be sure to insulate cable connection terminals. If the brushless ESC. To obtain 100% connection terminals are short-circuited, it may result in damage to this product.
  • Page 2 CONNECTIONS Connect the motor as shown below: To replace the motor cable, use a soldering iron which provides a large soldering WARNING tip area and high output (approx. 70W), and quickly conduct the soldering FAN power cable (Only when FAN is installed) work.
  • Page 3 Forced air-cooled Motor SPECIFICATIONS 10.5T 13.5T 4.8V〜11.1V Allowable voltage (V) 3,530 2,830 KV (rpm/V) Power (W) Efficiency (%) Sintered rotor, φ12.3 mm (Neodymium magnet) Rotor type Coil winding method Star-winding The specifications are subject to change without prior notice. *1: Allowable voltage of the motor. Pay attention to the ESC’s allowable voltage. *2: With 7.2 V input (4.5T: 6.0 V), Under no load REFERENCE GEAR RATIO Select an appropriate gear ratio based on the reference values listed below.
  • Page 4 ACUVANCE (Technical Service Department). ●ACUVANCE assumes no responsibility for damage or loss occurring during transportation of the  product. Please take note of this beforehand. ●  W hen listing the symptoms for a repair request, you can conveniently use the repair sheet on  the  ACUVANCE  homepage  and  then  send  this  along  with  the  warranty  card.  (Click  the  "repair"  section located in the upper-right side of our homepage. Then click "repair sheet", located on  the left side.) Repair card 1. Symptoms Write the symptoms of the problem, ...

This manual is also suitable for: