Mounting
Before mounting, make sure the device is
in a location where you can still push the
button to join it to the ZigBee network. If
the location will be difficult to reach, view
the instructions for ZigBee networking and
join the device to the network before
mounting.
A
Three Contact Sensors
The RJ12 jack provides 3 contact sensor
inputs. Contact sensor inputs are for dry
contacts only.
Contact Pinout
Name
Pins
Contact 1
C1&Com
Contact 2
C2&Com
Contact 3
C3&Com
Overview
The Relay & Contact Sensor-6 (RCS-6) is a
flexible tool to build a Control4 system
m o re ef fe c t i ve l y. It co m b i n e s t h e
capabilities of a repeater and router with 3
contact inputs and 6 relay outputs.
The repeater function allows more devices
to be joined to the network, and provides
more coverage for a ZigBee mesh network.
The RCS-6 contains a new high power
radio module and can support up to 16
child nodes.
Included
Relay & Contact Sensor Device
Terminal blocks
Mounting
The RCS6 has two holes for screws on
either side of the device. Depending on
wall material and location, consider using a
wall anchor. Distance between screws is
4.5" center to center.
B
Three Relays
6 Relay outputs with terminal blocks.
Relay connections are not polarized.
Relay Pinout
Name
Pins
Relay 1
R1&R1
Relay 2
R2&R2
Relay 3
R3&R3
Relay 4
R4&R4
Relay 5
R5&R5
Relay 6
R6&R6
Power Options
This device can be powered by 3.6V DC
adapter with either a North American,
European, Australia/China or UK plug. It
can also be powered via auxiliary power
terminal block connection that accepts a
6.5-24V AC or DC.
Mounting
Mount the device snugly to the wall.
C
Power
Alternative to the 3.6V plug-in power
suplies, you may supply power by
connecting 6.5-24V lines to the P1 and
P2 terminals, not polarized.

Advertisement

loading

Summary of Contents for Axxess Relay & Contact Sensor-6

  • Page 1 Overview Power Options The Relay & Contact Sensor-6 (RCS-6) is a This device can be powered by 3.6V DC flexible tool to build a Control4 system adapter with either a North American, m o re ef fe c t i ve l y. It co m b i n e s t h e European, Australia/China or UK plug.
  • Page 2 Contact & Relay Wiring Relay Specifications Contact Sensor & Relay Plugs DC Load on Relay For neatest installation, run wire suitable Max current = 1A for RJ12/45 crimping to the Repeater and Max voltage = 60VDC make plug connections. No Polarity AC Load on Relay Max current = 1A Max voltage = 40VAC...