DIGITAL TIMER INSTRUCTIONS (T4, T7)
1. CONNECT BATTERY
Open lid and attach battery to the snap, and then
insert battery in the holder.
2. SETTING THE TIME
The blue buttons on the side adjust the
time up and down left of the colon. To
program the digits right-of the colon, hold
down the green "stop/start" button while
adjusting the blue buttons. Model T7 will
have buttons on the circuit board inside.
3. SELECTING PROGRAM
• Different modes are selected by removing the
jumpers from the pins. (jumpers are located inside the box)
• JUMPER "A" on the pins selects minutes /seconds. For minutes/hours, remove
jumper "A".
• Other jumpers provide the logic according the this summary table.
MODE
JUMPER
B
C
1
ON
ON
2
OFF
ON
3
ON
OFF
4
OFF
OFF
5
ON
ON
6
OFF
ON
7
ON
OFF
8
OFF
OFF
✤ Some cycles intentionally do not allow cancellation. If allowed,
canceling a cycle is done by holding the green "stop/start" button for
about 2 seconds. Display will flash the last reading and buzzer
sounds.
4. OTHER
• For battery powered units, the alarm volume will diminish when voltage is low.
UP
DOWN
DESCRIPTION
D
ON
MANUAL CYCLE STOP - CAN CANCEL✤
ON
MANUAL CYCLE STOP - CAN NOT CANCEL
ON
REPEATING 2-SECOND RELAY PULSES
ON
ALTERNATING RELAY CYCLE -ON, THEN OFF
AUTOMATIC CYCLE STOP - CAN CANCEL ✤
OFF
OFF
AUTOMATIC CYCLE STOP - CAN NOT CANCEL.
OFF
GUARD DUTY
OFF
CUSTOM
Sep 18, 2014
START / STOP
JUMPERS
CDI Equipment
80 Metcalfe Street
Buffalo, NY 14206
800.777.2436 | sales@cdibuffalo.com
www.cdibuffalo.com