Download Print this page

nologo ZOOM-ZminiPLUS Instructions And Warnings

Infrared photocell new generation

Advertisement

Quick Links

ZOOM-ZminiPLUS
IR5001PSMINI
TX
Micro switch
1
1 2
1 - ON
abilita sincronismo solo 12/24Vac
activate the synchronisation only 12/24Vac
active la synchronisation 12/24Vac
1 - OFF disabilita sincronismo
deactivate the synchronisation
désactive la synchronisation
2 - ON
massima potenza (consigliato)
maximum power
maximale puissance(recommandée)
2 - OFF minima potenza (evita possibili riflessioni)
minimum power (avoid reflections)
minimale puissance (éviter situations de réflexion)
alimentazione / power supply /
alimentation
limiti alimentazione / limit power
supply / limites d'alimentation
portata / max. range up / portée
assorbimento TX / max. TX power
absorption / consommation TX
assorbimento RX / max. RX power
absorption / consommation RX
contatto relè di uscita / output relay
contact / type de relais
grado di protezione / protection /
protection
1 2
2
3
Vac/dc
13,5 / 24
18-35Vdc
15-28Vac
m
mA
mA
max 500mA
e 48Vac/dc
55 EN
IP
60529
Fotodispositivo infrarosso nuova generazione
Photocellule de nouvelle génération
Micro switch
1
1 2
1 - ON
1 - OFF disabilita sincronismo
2 - ON
2 - OFF ritarda di circa 300mS l'intervento del relè, "neve"
!!!!
!!!!
!!!!
20
25
In corrente alternata e a sincronizzazione abilitata, il led
sul RX rimane parzialmente acceso.
35
When you use in AC and the synchronisation is activated,
the light receiver remains partially lit.
Si la courant est alterné et si la synchronisation est acti-
vée, la LED sur le recepteur est partiellement allumée.
Infrared photocell new generation
Istruzioni ed avvertenze
Instructions and warnings
Instructions et notices d'emploi
RX
LED-C allineamento OK=ON
LED-C alignment OK=ON
LED-C alignement OK=ON
2
3
4
NC
abilita sincronismo solo 12/24Vac
activate the synchronisation only 12/24Vac
active la synchronisation 12/24Vac
deactivate the synchronisation
désactive la synchronisation
disabilita il ritardo e consente il sincronismo
deactivate the planing intervention time and you
can use the synchronisation
désactive temp d'intervention et permet la synchro-
nisation
Se si scieglie questa funzione
bisogna disabilitare il sincronismo 1- OFF !!!!
planning intervention time of 300mS relè, "snow"
If you use this function, don't use the
syunchronisation 1- OFF !!!!
temp d'intervention du relais de 300 ms, "neige"
Si vous choisissez de désactiver cette
fonctionnement il faut déactiver le
synchronisation 1- OFF !!!!
JUMPER
3
4
NA

Advertisement

loading

Summary of Contents for nologo ZOOM-ZminiPLUS

  • Page 1 Fotodispositivo infrarosso nuova generazione Infrared photocell new generation Photocellule de nouvelle génération ZOOM-ZminiPLUS Istruzioni ed avvertenze IR5001PSMINI Instructions and warnings Instructions et notices d’emploi Micro switch LED-C allineamento OK=ON LED-C alignment OK=ON LED-C alignement OK=ON Micro switch JUMPER 1 - ON...
  • Page 2 à leur parallélisme afin d’éviter tout phénomenés de réflexion indésirable. Dichiarazione CE conformità / EC declaration of confirmity / EG-Konformitatserklarung / Déclaration CE de conformité / Declaracion CE de conformidad ZOOM-ZminiPLUS / IR5001PSMINI è conforme alle seguenti disposizioni pertinenti:...

This manual is also suitable for:

Ir5001psmini