Power plug 14 /17/22
Mounting Instructions
2019-05-23
38-133905e
Description
The contact consists of two parts:
The vehicle section - contact box
Trailer section - socket
The socket and contact box have conduit entries
dimensioned for cables Ø10.5 mm - Ø17.5 mm. The
VBG Kontakt 14, 17 and 22 are designed such that the
socket automatically disconnects if you happen to forget
about it when uncoupling the trailer.
Identify all parts before assembly. All assembly and
service work must be performed carefully and in a
professional manner.
Follow the instructions. Always observe the vehicle
manufacturer's instructions for electrical installation on
the vehicle.
Leave all instructions and directions in the vehicle for
the customer for reference in future service and
maintenance.
General
• Cable dimension shall always be chosen taking
power consumption into consideration. When
dimensioning, keep in mind any extra equipment that
may be fitted at a later date.
• Connect the 14/17/22-terminal socket only to the
corresponding 14/17/22-terminal contact box. Risk for
short circuits.
14-terminal Black insert
17-terminal Red insert
22-terminal Green insert
• Weekly maintenance of the contact surfaces involves
cleaning and corrosion resistance using VBG Electro
Oil.
• To be absolutely assured that the connection between
the contact box and the socket is correct, an optional
lock hook is available, part number 28-027600.
• In particularly severe operating conditions, the contact
box should be equipped with a heating coil, part number
28-029900.

Advertisement

loading

Summary of Contents for VBG 14

  • Page 1 The socket and contact box have conduit entries dimensioned for cables Ø10.5 mm - Ø17.5 mm. The VBG Kontakt 14, 17 and 22 are designed such that the socket automatically disconnects if you happen to forget about it when uncoupling the trailer.
  • Page 2 8. Strip the wires about 5 mm. Fit cable shoes with the recommended dimensions. 9. Connect the cables to the flat connector blades in the insert as per the wiring plan. Spray with VBG Electro Oil onto the cable shoes and connector blades to prevent corrosion.
  • Page 3 9. Connect the wires to the blade connectors in the cartridge as per the wiring plan. Spray with VBG Electro Oil onto the cable shoes and connector blades to prevent corrosion.
  • Page 4 Member of VBG Group The strong connection www.vbg.eu...

This manual is also suitable for:

172228-02900028-03620028-02920028-046000 ... Show all