CyberPower CP850AVRLCD User Manual

CyberPower CP850AVRLCD User Manual

Advertisement

Quick Links

CP850/1000/1350/1500AVRLCD
User's Manual
PRODUCT REGISTRATION
Thank you for purchasing a CyberPower product. Please take a few minutes to register your product at www.cpsww.com/registration.
Registration certifies your product's warranty, confirms your ownership in the event of a product loss or theft and entitles you to free technical
support. Register your product now to receive the benefits of CyberPower ownership.
IMPORTANT SAFETY INSTRUCTIONS
(SAVE THESE INSTRUCTIONS)
This Manual Contains Important Instructions that should be followed during Installation and Maintenance of the UPS and batteries.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants.
(Please see specifications for acceptable temperature and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the battery. Turn off and unplug the unit before servicing
the batteries. There are no user serviceable parts inside except for the battery.
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not
grounded. If you need to de-energize this equipment, turn off and unplug the unit.
CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before servicing the battery.
CAUTION! Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment,
ANSI/NFPA 75.
CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in
accordance with the National Electric Code, ANSI/NFPA 70.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or medical
applications. DO NOT use in any circumstance that would affect the operation and safety of life support equipment, medical applications, or patient
care.
DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation
from the aquarium can cause the unit to short out.
DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use the unit on any transportation such as
airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out.
INSTALLING YOUR UPS SYSTEM
INTRODUCTION
Thank you for selecting a CyberPower Systems UPS product. This UPS is designed to provide unsurpassed power protection, operation and
performance during the lifetime of the product.
UNPACKING
Inspect the UPS upon receipt. The box should contain the following:
(a) UPS (b) User's manual (c) USB A+B type cable (d) Function Setup Guide
*PowerPanel® Personal Edition software is available on our website.
Please visit www.cpsww.com and go to the Software Section for free download.
OVERVIEW
The CP850/1000/1350/1500AVRLCD provides complete power protection from utility power that is not always consistent.
The CP850/1000AVRLCD features 1080 Joules and the CP1350/1500AVRLCD features 1500 Joules of surge protection.
The unit provides long lasting battery backup during power outages with maintenance free batteries.
The CP850/1000/1350/1500AVRLCD ensures consistent power to your computer system and includes software that will automatically shut down
your computer system during a utility power loss.
AUTOMATIC VOLTAGE REGULATOR
The CP850/1000/1350/1500AVRLCD stabilizes inconsistent utility power voltage to nominal levels that are safe for equipment. Inconsistent incoming
utility power may be damaging to important data files and hardware, but with Automatic Voltage Regulation (AVR), damaging voltage levels are
corrected to safe levels. AVR automatically increases low utility power or decreases high utility power to a consistent and safe 110/120 volts.
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Ensure that the equipment plugged into the outlet does not exceed the UPS's rated capacity (850VA/510W for CP850AVRLCD,
1000VA/600W for CP1000AVRLCD, 1350VA/815W for CP1350AVRLCD, 1500VA/900W for CP1500AVRLCD. If the rated capacity of the unit is
exceeded, an overload condition may occur and cause the UPS to shut down or the circuit breaker to trip.
2. There are many factors that can affect the amount of power that your computer system will require. It is suggested that the load placed on the
battery outlets not exceed 80% of the unit's capacity.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure the
battery's maximum charge capacity, it is recommended that you charge the battery for at least 8 hours.
Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the
battery will automatically charge whether the UPS is turned on or off.
2. Note: This UPS is designed with a safety feature to keep the system from being turned on during shipment.
The first time you turn the UPS on, you will need to have it connected to AC power or it will not power up.
3. With the UPS unit turned off and unplugged, connect your computer, monitor, and any other peripherals requiring battery backup into the battery
power supplied outlets. DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large electrical
devices into the "Battery and Surge Protected Outlets". The power demands of these devices may overload and damage the UPS.
4. To protect a fax, phone or modem, connect a telephone cable or network cable from the wall jack outlet to the IN jack of the UPS. Connect a
telephone cable or network cable from the OUT jack of the UPS to a fax machine, telephone, modem, or network devices.
5. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is
protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air
conditioner, copier, etc...). The warranty prohibits the use of extension cords, outlet strips, and surge strips.
6. Press the power switch to turn the unit on. The Power On indicator light will illuminate and the unit will "beep".
If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at least
one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.
7. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
8. To store the UPS for an extended period, cover it and store with the battery fully charged. While in storage, recharge the battery every three
months to ensure battery life.
9. Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility.
BASIC OPERATION
DESCRIPTION
CP850/1000AVRLCD
1.
Power Switch
Used as the master on/off switch for equipment connected to the battery power supplied outlets. (Please refer to the Function Setup Guide
for more information.)
2.
Power On Indicator
This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.
3.
LCD module display
The LCD display shows all the UPS information using icons and messages. For more information please review the "Definitions for Illuminated
LCD Indicators" section below.
4.
Display/Select Button
The button can be used to select the LCD display contents including Input Voltage, Output Voltage, and Estimated Run Time. Short press the
button to scroll down the function menu. Pressing the button for 3 seconds will keep the LCD display always on or turn the LCD display off while
in AC/Utility power mode. For more information, please refer to the Function Setup Guide.
K01-0000501-00
CP1350AVRLCD
CP15000AVRLCD
5.
Mute/Enter Button
Holding the button for more than 3 seconds will silence the alarm. Short press the ENTER button to confirm the setting. After the setting has
been confirmed, the LCD screen will stop flashing. For more information, please refer to the Function Setup Guide
6.
Battery and Surge Protected Outlets
The UPS has battery powered/surge suppression outlets for connected equipment to ensure temporary uninterrupted operation of your
equipment during a power failure. (DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other
large electrical devices into the "Battery and Surge Protected Outlets". The power demands of these devices may overload and
damage the unit.)
7.
Full-Time Surge Protection Outlets
The UPS has surge suppression outlets.
8.
Circuit Breaker
Located on the back of the UPS, the circuit breaker serves to provide overload and fault protection.
9.
Serial/USB Ports to PC
The USB port allows connection and communication between the USB port on the computer and the UPS unit.
10. Communication Protection Ports
Communication protection ports will protect any standard modem, fax, telephone line, network or Ethernet connection (RJ11/RJ45).
11. Wiring Fault Indicator (red)
This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring. If this is
illuminated, disconnect all electrical equipment from the outlet and have an electrician verify the outlet is properly wired. The UPS will not provide
surge protection without being plugged into a grounded and properly wired wall outlet.
12. Coax/Cable/DSS Surge Protection
The Coax/Cable/DSS protection ports will protect any cable modem, CATV converter, or DSS receiver.
13. Outlets Designed for AC Adapters
The unit has two outlets spaced to allow AC power adapter blocks to be plugged into the UPS without blocking adjacent outlets.
REPLACING THE BATTERY
Replacement of batteries located in an OPERATOR ACCESS AREA.
1.
When replacing batteries, replace with the same number of the following battery: CyberPower RB1290A for the CP850/1000AVRLCD;
CyberPower RB1290X2 for the CP1350/1500AVRLCD
2.
CAUTION! Risk of Energy Hazard, 12 V, maximum 9 Ampere-hour battery for CP850/1000AVRLCD; 24 V, maximum 9 Ampere-hour battery
for CP1350/1500AVRLCD. Before replacing batteries, remove conductive jewelry such as chains, wrist watches, and rings. High energy
conducted through these materials could cause severe burns.
3.
CAUTION! Do not dispose of batteries in a fire. The batteries may explode.
4.
CAUTION! Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic.
5.
CAUTION: A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when
working on batteries:
1) Remove watches rings, or other metal objects.
2) Use tools with insulated handles.
CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO
LOCAL REGULATIONS.
BATTERY REPLACEMENT PROCEDURE:
CP850/1000/1500AVRLCD
1.
Turn off and unplug all connected equipment.
2.
Turn the UPS off and unplug it from the AC power source.
3.
Turn the UPS on its side.
4.
Remove the front panel retaining screws located on the bottom of the UPS.
5.
Slide the battery compartment cover (front panel) completely off of the unit.
6.
Disconnect the battery wires from the batteries.
7.
Remove the batteries from the compartment.
8.
CP850/1000AVRLCD: Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same color connectors.
9.
CP1500AVRLCD: Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same color connectors from both the
upper and lower battery pack. Note: Only use new batteries for replacement and both batteries should be replaced at the same time to ensure
maximum life span.
10.
Put the batteries back into the compartment.
11.
Slide back the battery compartment cover and tighten the retaining screws.
12.
Recharge the UPS for 8-16 hours to fully charge the battery.
CP850/1000AVRLCD
CP1500AVRLCD
CP1350AVRLCD
1.
Turn off and unplug all connected equipment.
2.
Turn the UPS off and unplug it from the AC power source.
3.
Turn the UPS on its side.
4.
Remove two retaining screws located on the bottom of the UPS.
5.
Slide the battery compartment cover completely off of the unit.
6.
Remove the battery which is located on the right side from the compartment.
7.
Disconnect the battery wires from the right side of the battery.
8.
Slide the remaining battery from left to right and remove it from the compartment.
9.
Disconnect the battery wires from the remaining battery.
10.
Install the "left side" replacement battery by connecting the yellow wire (+) to the red connector from the battery and the black wire (-) to the
black connector from the battery. Place the battery into the left side of the compartment.
11.
Install the "right side" replacement battery by connecting the red wire (+) to the red connector from the battery and yellow wire (-) to the black
connector from the battery. Place the battery into the right side of the compartment. Note: Only new batteries should be used for replacement
and both batteries should be replaced at the same time to insure maximum life span.
12.
Slide back the battery compartment cover and tighten the retaining screws.
13.
Recharge the UPS for 8-16 hours to fully charge the battery.
Yellow Wire to (+)Red Connector
Black Wire to (-)Black Connector
REMINDER: Batteries are considered HAZARDOUS WASTE and must be disposed of properly. Most retailers that sell lead-acid batteries collect
used batteries for recycling, as required by local regulations.
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
1.
INPUT voltage meter:
This meter measures the AC voltage that the UPS system is receiving from the utility wall outlet. The UPS is designed, through the use of
automatic voltage regulation, to continuously correct output voltage to connected equipment to a safe 120 voltage output range. In the event of
a complete power loss, severe brownout, or over-voltage, the UPS relies on its internal battery to supply consistent 110/120 output voltage.
The INPUT voltage meter can be used as a diagnostic tool to identify poor-quality input power.
Red Wire to (+)Red Connector
Yellow Wire to (-)Black Connector
The LCD screen indicates a variety of UPS operational
conditions. All descriptions apply when the UPS is plugged
into an AC outlet and turned on or when the UPS is on
battery.

Advertisement

loading

Summary of Contents for CyberPower CP850AVRLCD

  • Page 1 CyberPower RB1290X2 for the CP1350/1500AVRLCD DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or medical CAUTION! Risk of Energy Hazard, 12 V, maximum 9 Ampere-hour battery for CP850/1000AVRLCD; 24 V, maximum 9 Ampere-hour battery applications.
  • Page 2 If the Product is defective in material or workmanship, CyberPower will repair or replace it at CyberPower's expense, or, if CyberPower is unable to or decides not to repair or replace the Product (if defective) within a reasonable time, CyberPower will refund to you the full purchase price you paid for the Product (purchase receipt showing price paid is required).