Installation Guide – Sediment Filter
Pre-Installation
1. The maximum water temperature in contact with the filter should not exceed 100°F (38°C) at 40 PSI.
2. The maximum water pressure within the filter should not exceed 150 PSI at 73°F (23°C). Colder temperatures reduce the
maximum operating pressure.
3. The Sediment Filter warranty does not cover any defects that may arise from use with non-potable water, chemicals or
other fluids.
4. Lubricants used on O-rings can contain chemicals that are not compatible with filter components. Silicone grease (DOW
111) should be the only lubricant used on O-rings.
NOTE: The filter should be installed in a location that protects it from damage. Potential filter damage considerations should
include impact, freeze, excessive heat, sunlight, chemical contact and water-hammer.
5. Adhere to all local and state codes, laws, and regulations when installing the filter.
Installation
1. Remove the filter bowl (E) and the filter cap O-ring (D) from the PVC Filter Cap (A).
NOTE: It is recommended that the filter bowl be removed from the PVC body prior to the gluing process, as any excess glue
that comes in contact with the filter bowl will cause damage and void the warranty.
2. The filter cap can be used with either 1 in. or 1-1/4 in. PVC pipe. If using with 1 in. PVC pipes, prime and glue the inside of
the filter cap (A) inlet and outlet as well as the outside of the PVC pipes. Insert the pipe directly into the filter cap and allow
the glue to set. If using with 1-1/4 in. PVC pipes, prime and glue the outside of the filter cap (A) inlet and outlet as well as
the inside of 1-1/4 in. PVC adapters. Slip the adapters over the filter cap inlet and outlet, then connect the appropriate pipes
to the adapters.
IMPORTANT: Be sure the arrow on the top cap follows the flow of water.
NOTE: Use approved PVC primer and solvent cement for gluing PVC
connections. Follow gluing instructions outlined on solvent container.
3. Push the 100 mesh filter screen (C) into the bottom of the filter cap (A).
4. Place the filter cap O-ring (D) on top of the filter bowl (E). It will fit around the raised lip.
5. Thread the filter bowl (E) into the filter cap (A). Ensure the O-ring (D) stays in place.
IMPORTANT: HAND TIGHTEN ONLY. Do not use thread tape or pipe dope on this connection! The O-ring creates the seal.
6. Thread the flush valve (F) on to the bottom of the filter bowl (E). FINGER TIGHTEN ONLY PLUS 1 or 2 TURNS.
IMPORTANT: The use of quality pipe joint compound approved for use with PVC is recommended. If using P.T.F.E. thread
seal tape, uneven and/or over application of tape may result in flush valve failure due to stress cracking in all types of
PVC/plastic fittings and valves.
For replacement parts, filters, or other well and irrigation accessories, please visit www.watersourceusa.com or call us at 1-800-346-7611
A
Item
Quantity
B
A
C
B
D
C
E
D
E
F
F
Description
1
Filter Cap (1 in. slip or 1-1/4 in. spigot)
1
Filter Screen O-ring (pre-attached)
1
100 Mesh Filter Screen
1
Filter Cap O-ring
1
Filter Bowl
1
Flush Valve
Model Number
WSSFFH
WSSFOR1
SFS-100
WSSFOR2
WSSFSB
WSSFD
E
A
C
F

Advertisement

loading

Summary of Contents for Watersource SFS-30

  • Page 1 Installation Guide – Sediment Filter Pre-Installation Item Quantity Description Model Number Filter Cap (1 in. slip or 1-1/4 in. spigot) WSSFFH Filter Screen O-ring (pre-attached) WSSFOR1 100 Mesh Filter Screen SFS-100 Filter Cap O-ring WSSFOR2 Filter Bowl WSSFSB Flush Valve WSSFD 1.
  • Page 2 Screen Mesh/ Micron Conversion Larger Model # Mesh Microns Opening Example of Sediment Protects Openings SFS-30 .0210 in. General Usage (Debris), Coarse Sand General Use, Sprinkler Heads SFS-40 .0150 in. SFS-60 .0100 in. Pipe Scale, Medium Sand Larger Sprinkler Heads, Other Valves *SFS-100 .0060 in.

This manual is also suitable for: