Download Print this page
EasyPro TB Series Instructions For Operation

EasyPro TB Series Instructions For Operation

Submersible high head waterfall pumps

Advertisement

Quick Links

Replacement Parts
9
5
4
10
8
No.
Description
Material
1
Cord
B Series Pumps
2
Motor Casing
Stainless Steel 304
3
Motor Cover
Die Casting FC-200
4
Bearing
NBR
5
Motor Shaft
Stainless Steel 403
6
Mechanical Seal
Silicone Carbide & Ceramic
7
Impeller
Die Casting FC-200
8
Pump Base
Die Casting FC-200
9
Handle
Stainless & NBR
10
Discharge
PE & Die Casting FC-200
EasyPro Pond Products Limited Warranty
1
EasyPro Pond Products ("EasyPro") warrants to the purchaser that this
product (TB Series Submersible High Head Waterfall Pump) will be free
from any mechanical or material defects for a period of two years from
the date of purchase. This warranty does not cover accidental damage to
3
the product due to abuse or negligence by the consumer. This warranty
only covers properly installed and maintained Products sold by authorized
EasyPro Sellers who are subject to and follow EasyPro's quality control
standards. Please note that because EasyPro is unable to control the
2
quality of Products sold by unauthorized sellers, unless otherwise
prohibited by law, this warranty does not cover Products purchased from
unauthorized sellers.
This warranty does not cover normal wear and tear, nor any deterioration
6
suffered through overloading, improper use, negligence, improper
installation, acts of God or accident. Similarly, any modification made by
the purchaser to the Product will cause the warranty to be null and void.
7
This warranty does not cover any cost associated with the installation or
removal of the Product subject to a warranty claim.
All returned items will be inspected to determine cause of failure
before a warranty claim is approved. The exclusive remedies provided
hereunder shall, upon EasyPro's inspection and option, be either repair
or replacement of the Product or parts covered under this warranty.
Making a Claim: A Return Authorization ("RA") number must first be obtained
by calling EasyPro at 800-448-3873 or via email at warranty@easypro.com.
It is the purchaser's responsibility to pay the return shipping charges. Be sure
to include the RA number, original receipt (in the form of an invoice or sales
receipt), your name, your return address and your phone number inside of
the package. No warranty claims will be honored without the original receipt
that shows that your purchase was made from an Authorized EasyPro Seller.
Ensure the product is properly packaged and insured for the replacement
value. Damage due to improper packaging is the responsibility of the sender.
ALL OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING
MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE ARE
HEAREBY LIMITED IN DURATION TO THE DURATION OF THE WARRANTY
AS DESCRIBED ABOVE. Some States do not allow limitations on how long
an implied warranty lasts, so the above limitations may not apply to you.
EasyPro shall not be held liable for any damages caused by defective
components or materials of this Product; or for loss incurred because of
the interruption of service; or any consequential/incidental damages and
expenses arising from the production, sale, use or misuse of this Product.
Some States do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply
to you.
EasyPro shall not be held liable for any loss of fish, plants or any other
livestock as a result of any failure or defect of this Product. This warranty
gives you specific legal rights, and you may also have other rights that vary
from State to State.
www.easypro.com • info@easypro.com
800-448-3873 • Grant, Michigan
5454 • 10/19
TB8000 • TB8002 • TB12000 • TB14500
TB Series Submersible High Head
Waterfall Pumps
Instructions for Operation • Safety • Warranty
Designed for use with higher head pressure
Thank you for purchasing the TB series waterfall pump.
This instruction manual explains the product operations
and gives important precautions regarding its safe
use. In order to use the product to maximum benefit,
be sure to read the instructions thoroughly and follow
them carefully.
Specifications
3" outlets
Automatic thermal overload protection
Double silicone carbide mechanical seals with
100,000 hour life expectancy
TB8000 available as 230v or 115v, TB12000 and TB14500 available
as 230v only
Two year limited warranty
A minimum of 20' head pressure required for TB12000 and TB14500
70'
60'
50'
40'
30'
20'
10'
0'
GPH
1000
2000
3000
4000
5000
6000
7000
8000
9000
|
|
|
|
|
|
|
GPM
20
40
60
80
100
120
140
Beyond operating capacity
10000 11000 12000 13000 14000
|
|
|
|
160
180
200
220
Best efficiency

Advertisement

loading

Summary of Contents for EasyPro TB Series

  • Page 1 EasyPro shall not be held liable for any loss of fish, plants or any other livestock as a result of any failure or defect of this Product. This warranty gives you specific legal rights, and you may also have other rights that vary from State to State.
  • Page 2 WARNING: Must be vented in accordance with local plumbing codes. debris • Has any damage occurred during shipment? EasyPro pumps are not designed for and CANNOT be installed in • Are any bolts or nuts loose? locations classified as hazardous.

This manual is also suitable for:

Tb8000Tb8002Tb12000Tb14500