Quick Links

Features
Simple to Install -The DoorGard 212LS Lockset installs in 15 minutes
and programs the same as all DoorGard/IEI keypads. It includes
all mounting hardware, and easily retrofits into any standard cylindrical
door prep (ANSI/BHMA A 156.2-2003). The 212LS has a replaceable
core, for the manual key override. The sleek design fits with any décor
and is available in 26D Stainless and US3 Polished Brass, right or left
handed crescent door handles.
Right Hand
212LS – C26DCR-Rt - F/G:DoorGard Grade 2 Lockset/Cylindrical,
Stainless, Crescent handle, Right handed.
212LS – CUS3CR-Rt - F/G: DoorGard Grade 2 Lockset/Cylindrical,
Stainless, Crescent handle, Right handed.
Left Hand
212LS – C26DCR-Lt - F/G: DoorGard Grade 2 Lockset Cylindrical,
Stainless, Crescent handle, Left handed.
212LS – CUS3CR-Lt - F/G: DoorGard Grade 2 Lockset Cylindrical,
Stainless, Crescent handle, Left handed.
Easy to Maintain -Change the battery in three minutes. The 212LS
Lockset uses four (4) 1.5V AA batteries for up to 15,000 uses or up to
five years. An alarm activates Low Battery Alert allowing for 30 more
uses.
User Codes - The 212LS lock recognizes up to 120 users with a
different code for each, and the lockset retains codes without batteries.
Codes can be one to six digits in length and digits can be repeated.
The Master Code is always stored in user location one (1). A reset
button is provided inside the lock which restores factory defaults and
removes codes already stored. The lockset is equipped with an override
mechanical key.
The code toggles to allow passage for an event so any
key will open the lock.
Security and Protection -The 212LS Lockset is designed with a
safeguard against forced entry since the outside lever is not
mechanically connected to the latch until the lock activates. Also, after
three invalid code attempts, there is a 20 second lockout period for the
keypad.
Rugged Design -The 212LS is designed for both commercial and
industrial use.
Lockset Parts List
1. Spanner wrench
11. Interior Faceplate/Door
2. T-Strike Door Latch
Handle w/battery case
2-3/8" Backset
12. Interior Faceplate
3. T-Strike Door Latch
13. Override Keys (2)
2-3/4" Backset
14. Pin Wrench (pries open key
4. Strike Plate
slot cover)
5. Strike Plate Cover
15. Key Slot Cover
6. Latch/Strikeplate Screws
16. Screws: 2 sets Lock
7. Allen Wrench
Assembly screws (thick,
8. Exterior Door Handle/
thin doors)
keypad
17. Sealing Washer
9. Exterior Gasket
18. Faceplate Assembly Nut
10. Interior Gasket
2
3
1
7
8
10
9
13
14
15
16
17
Figure 1. Parts Diagram
Door & Frame Prep
Remove existing Lock from door
If it is new door with no holes, use
Measure backset.
1. Unpack the lockset and inventory all parts. Remove mount-
ing screws, separate lock assembly, and both interior/exterior
handle plates and the two rubber gaskets.
2. Insert the strike plate hole cover (#5) and attach strike plate
(#4) in the door jam/frame, securing with two Phillips head
screws.
3. Install T-Strike Door Latch (#2 or #3) into doorjam/frame and
secure with two Phillips head screws.
4. Assemble locks inserting two Rubber Gaskets (#8, 9, 10, 11).
5. Thread battery wires through hole in Interior Faceplate/Door
Handle (#11).
4
6
6. Attach Interior Faceplate/Door Handle (#11) to Exterior Door
5
Handle (#8), securing with two short or long assembly screws.
(#16)
7. Insert batteries and connect battery clip.
12
8. Secure Interior Faceplate (#12) with clear plastic washer with
Nut (#17, 18)
9. Use spanner wrench (#1) to tighten nut (#15).
10. Program the system as described in this manual.
11
11. Instruct the users on lockset operation.
Use Pin Wrench (#14) to pull off cover (#15).
18
Use override key (#13).
Turn left twice.
Installation Steps
template
provided
Installation
Manual Operation
P1345

Advertisement

loading

Summary of Contents for Linear IEI DoorGard 212LS Series

  • Page 1 Features Installation Steps Lockset Parts List Simple to Install -The DoorGard 212LS Lockset installs in 15 minutes Door & Frame Prep 1. Spanner wrench 11. Interior Faceplate/Door • and programs the same as all DoorGard/IEI keypads. It includes Remove existing Lock from door 2.
  • Page 2 Green LED stops flashing dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out Enable any Key Access of or in connection with use or performance of this product or other indirect Now Part of damages with respect to loss of property, revenue, or profit, or cost of removal,...

This manual is also suitable for:

Iei doorgard 212ls-c26dcr-rt-fIei doorgard 212ls-c26dcr-rt-gIei doorgard 212ls-cus3cr-rt-fIei doorgard 212ls-cus3cr-rt-gIei doorgard 212ls-c26dcr-lt-fIei doorgard 212ls-c26dcr-lt-g ... Show all