Contact the Acc Inc sales department with any questions. Copyright Accumulators, Inc. Accumulators, Inc., AccuMight, accumulators.com, and Acc Inc names and logos are registered trademarks and service marks of Accumulators, Inc. 18435 Morton Road, Houston, TX 77084 USA P: 713-465-0202 F: 713-468-1618 E: info@accumulators.com...
Page 2
9. Piston accumulator assembly In accordance with the recommendations of Accumulators, DESCRIPTION Inc., piston accumulators must be securely mounted and These installation, operation and care instructions apply to vibration free using approved Accumulators, Inc. clamps and Accumulators, Inc. piston accumulators only.
Page 3
A. NOTE: If the gland and nut do not fit, the wrong gas or wrong pressure is being used. 3a. For 3000 psi accumulators: Rotate “T” handle CCW so it is all the way out before attaching air chuck. Attach the air chuck to the accumulator gas valve by hand, tightening its swivel hex connection, see photo B.
Check the inside of the shell for rough spots and grooves. If 5. Loop a sturdy ribbon around defects are found, Accumulators, Inc. can re-machine the the o-ring. cylindrical shell (within certain tolerances). Please contact us for details.
Page 5
7. If not using accumulator immediately, apply aerosol anti- corrosive through open gas port. 8. Fit the gas valve and all adapters and other accessories. 9. Connect the Accumulators, Inc. charging and gauging kit and charge the accumulator according to the PRECHARGING INSTRUCTIONS section.