Download Print this page

Identiv Freedom 50-40-1 Installation Manual

Single port bridge

Advertisement

Quick Links

Single Port (FB1) Freedom Bridge
Installation Guide
PART NUMBERS
PHYSICAL SPECIFICATIONS
Length
Width
Height
Weight
Max Readers
Max Input
Max Output
Certifications
BASE PLATE MOUNTING
Dimension
Millimeters
A
116.07
B
78.74
C
15.24
D
85.59
E
10.16
F
58.42
E
F
SUMMARIZED LEVELS OF
ACCESS CONTROL COMPONENTS
Destructive Attack
Line Security
Endurance
Standby Power
Single Point Locking
50-40-1, 50-40-1L
76 mm (3.00 in.)
47 mm (1.85 in.)
17 mm (0.67 in.)
26 g (1.20 oz.)
1
2
1
Electrical: UL294 and UL294B
Power over ethernet: IEEE 802af
EMI Radiation: FCC Part 15 Class B
Inches
4.57
3.10
0.60
3.37
0.40
2.30
D
C
B
A
Level I
Level I
Level I
Level I
Level I
identiv.com
sales@identiv.com
INSTALLATION REQUIREMENTS
Freedom Bridges should only be installed in dry, non-condensing
environments. The ambient temperature of the environment should
range between -40°C and 50°C.
Freedom Encryption Bridges should only be mounted to non-conductive
surfaces. Incorrect mounting may short-circuit the electronics, which will
cause it to malfunction.
DC power, reader, input contact, and output device wires should
be between 16-28 AWG. They should also be stripped 5.5mm to
sufficiently fit the terminal blocks and ensure that they do not come in
contact with each other.
INSTALLATION PROCEDURE
For each of the following steps, be sure to reference the wiring
diagram on page 2 for additional details:
1.
Connect a Wiegand Reader to the Wiegand Reader Input on the
Freedom Bridge.
A.
If the reader has a shield wire, connect the shield wire
to the 0v terminal on the Wiegand Reader Input. If an
extension cable is used between the reader and the
Freedom Bridge, connect the reader's shield wire to the
cable's shield, then connect the cable's shield to the 0v
terminal on the Wiegand Reader Input.
B.
Any unused wires on the reader must be evenly snipped
and have their tips insulated using electrical tape or
equivalent. The shield wire on the reader must also be
completely insulated.
2.
If you have any supervised input contacts, wire them to the Digital
Contact Inputs using Method 1 or Method 2.
3.
If you have any non-supervised input contacts, wire them to the
Digital Contact Inputs.
4.
If you have a relay output contact, wire it to the Relay Output.
5.
Supply power to the Freedom Bridge using either or both of the
following methods:
A.
A 2.25 – 5.25 W Power over Ethernet (PoE) port on an
Ethernet switch connected to the Freedom Bridge using a
Cat5e or Cat6 cable.
B.
12 – 16 Vdc & 350 mA (300 mA external & 50 mA
internal) DC power connected directly to the TB1 terminal
on the Freedom Bridge.
6.
If you are not using PoE to power your Freedom Bridge, connect
a Cat5e or Cat6 cable from any port on an Ethernet switch to the
RJ- 45 connector on the Freedom Bridge. Note: Ethernet only
supports a maximum cable length of 100 m.
7.
To configure and add the Freedom Bridge to a MESH/Freedom
Server, refer to the MESH/Freedom Solution Guide manual.
+1 888-809-8880
50-24-1

Advertisement

loading

Summary of Contents for Identiv Freedom 50-40-1

  • Page 1 Standby Power Level I supports a maximum cable length of 100 m. Single Point Locking Level I To configure and add the Freedom Bridge to a MESH/Freedom Server, refer to the MESH/Freedom Solution Guide manual. identiv.com sales@identiv.com +1 888-809-8880 • •...
  • Page 2 Relay Contact AC: 60 Vac @ 0.5 Aac Identiv (NASDAQ: INVE) is a global provider of physical security and secure identification. Identiv’s products, software, systems, and INSTALLATION GUIDE services address the markets for physical and logical access control, video analytics and a wide range of RFID-enabled applications.

This manual is also suitable for:

50-40-1lEnterphone 50-24-1