SL-166A(B) Dead Bolt Lock Installation Manual
Features
Use for 90 ~180 open hollow metal or solid wooden doors.
Built-in microcontroller. Automatic current output control
according to the door leaf position. The current is being
lowered to 210mA after 6 seconds of door leaf positioning
in order to cut down power consumption and lower the
temperature of the lock body.
Special wearable design. Mechanic life of more than
200,000 times.
Adjustable wiring methods according to the environment.
Adjustable lock time( 0 sec. & 3 sec. ).
1 set of push button control contact is available.
Lock indicator is available for lock status.
Specifications
Power supply
DC 12V
Standby:210mA 10%;
Operation current
Operation:570mA 10%
Delay Time
0,3
Door position reed contact (0.25A@30VDC)
Lock status sensor
Operation temperature
Maximum 41
Operation environment
Temperature 0-70 ,Humidity85%Rh max
14mm (Throw) X 12.7mm (Diameter)
Bolt
More than 200,000 times
Mechanic life
(1)Fail-safe electric lock
(2)Built-in photo couplers door open
Safety Measures
Connections
Adjusting before installation
1
Unscrew the top cover, adjust delay time.
Lock Control - Kouterbaan 63 - 1840 Malderen - Belgium - Tel. +32 52 57 43 02 - info@lockcontrol.be - www.lockcontrol.be
10%
sec.( Adjustable)
(
Room temperature 30
push button input contact.
Door will lock again automatically when
door is not open within 6 seconds.
Attention: There are only 2 screws on the back of the panel.
Red:
Brown:
Green:
Push button input contact
Blue:
COM.
Purple:
N.C.
Yellow:
N.O.
2
Accessories
Lock body X 1
Strike plate X1
X2 Shims(large)
For lock body
Current and Temperature Chart
If delay time of 3 seconds.
Door Close
Current
Door Lock
(MA)
Delay Timer
)
( Environment: Room temperature 30 ,
Humidity 60% Rh, DC12V )
60
50
Temperature
40
30
20
Door closed when power is on.
Current input
Push button contact as dry contact. NO voltage input to prevent
damage to the unit.
SL-166A has NC and COM contacts
Door position detection reed is only able to sustain load of
0.25A@30VDC. An external relay is suggested if higher current
to control.
The wires through the
rubber hole
Adjusting automatic lock time:
(Reset after adjusting)
0
3
SEC.
SEC.
(Default)
5-PIN Connector
39
Screws
M5X25mm
3.5
M4X15mm
M5X8mm
M4X8mm
X2 Shims(small)
For strike plate
Start
Stand-by
Wiring direction according to the
3
environment.
OR
Screws
X 2
Screws
X 4
Screws
X 4
Screws
X 8
Unit: mm
5
Time (sec.)
Time (sec.)
Page 1

Advertisement

loading

Summary of Contents for Lock Control SL-166A

  • Page 1 Unscrew the top cover, adjust delay time. environment. rubber hole Adjusting automatic lock time: (Reset after adjusting) SEC. SEC. (Default) Lock Control - Kouterbaan 63 - 1840 Malderen - Belgium - Tel. +32 52 57 43 02 - info@lockcontrol.be - www.lockcontrol.be Page 1...
  • Page 2 The unlock operation temperature of the lock is normally within 41 . It is considered normal if the temperature is within 41 . Lock Control - Kouterbaan 63 - 1840 Malderen - Belgium - Tel. +32 52 57 43 02 - info@lockcontrol.be - www.lockcontrol.be Page 2...

This manual is also suitable for:

Sl-166b