Download Print this page
Cooper Lighting NeoSwitch ONW-D-1001-MV-N-W Installation Instructions

Cooper Lighting NeoSwitch ONW-D-1001-MV-N-W Installation Instructions

Dual technology single relay occupancy sensing wall switch (neutral required)

Advertisement

Quick Links

Installation
Instructions
General Information
• Read all instructions on both sides of this
• Install in accordance with ALL local codes
sheet first
• For indoor use only
Specifications
Technology: Passive Infrared (PIR) and Ultrasonic (US)
Coverage: Major motion – 1000 sq. ft.
Electrical Ratings:
Minor motion – 300 sq. ft.
Light Level Sensing: 0 to 200 foot-candles
120 VAC:
• Incandescent/Tungsten –
Operating Environment:
Max. load: 6.7 amps, 800W, 50/60 Hz
• Temperature: 32° F – 104° F (0° C – 40° C)
• Fluorescent/Ballast –
• Relative Humidity: 20% to 90% Non-condensing
Max. load: 10 amps, 1200W, 50/60 Hz
Housing: Durable, injection molded housing.
Motor Load: ¼ HP @ 125 VAC
Polycarbonate resin complies with UL 94VO.
230/277 VAC:
Size:
• Fluorescent/Ballast –
• Mounting Plate/Strap Dimensions:
Max. load: 9.8 amps, 2700W, 50/60 Hz
4.195" H x 1.732" W (106.553 mm x 44 mm)
120/277 VAC:
• Product Housing Dimensions: 2.618" H x 1.752" W
• Electronic Ballast – Max. load: 3 amps (LED)
x 1.9" D (66.5 mm x 44.5 mm x 48.26 mm)
Ballast Compatibility: Compatible with magnetic and
LED Indicators: Red LED indicates PIR detection;
electronic ballasts
Green LED indicates Ultrasonic detection; Green LED
No Minimum Load Requirement
acts as EcoMeter or night light locator.
Time Delays: Self-Adjusting, 15 seconds/test
(10 min Auto), Selectable 5, 15, 30 minutes
Description
The ONW-D-1001-MV-N Occupancy Sensing Wall Switch is a Passive Infrared (PIR) and Ultrasonic (US) motion
sensing lighting control and conventional wall switch all-in-one, used for energy savings and convenience.
The sensor combines PIR and US technologies to monitor a room for occupancy.
PIR Technology
The sensor's segmented lens divides the field of view into sensor zones, and detects the changes in temperature
that are created when a person, or part of a person as small as a hand, passes into or out of a sensor zone.
US Technology
The sensor produces a low intensity, inaudible sound. It detects occupancy from changes in the acoustic waves
caused by motion, such as reaching for a telephone, turning a page in a book, walking into a room, turning in a
swivel chair, etc. The sensor does not respond to audible sound.
Dual Technology sensors ensure the greatest sensitivity and coverage for tough applications thus saving additional
energy. PIR is used to turn the lights ON and then either or both technologies are used to keep the lights ON.
The ONW-D-1001-MV-N allows the control of one load with one occupancy sensor switch.
The sensor can be configured to enhance energy savings by setting the unit for manual ON operation.
In Automatic ON Mode, the lights turn ON automatically when a person enters the room. In Manual ON Mode, the
lights are turned ON by pressing the universally recognized light icon pushbutton. In either mode, the lights stay
ON as long as the sensor detects motion in the room. When the room is vacated, the lights turn OFF automatically
after a preset time delay interval.
The sensor includes self-adaptive technology that continually adjusts to conditions by adjusting sensitivity
and time delay in real-time. By adjusting sensitivity and time delay automatically, the sensor is maximizing the
potential energy savings that are available in the particular application.
The EcoMeter provides a visual indicator of energy usage, increasing end user awareness and reminding
individuals to take control of their lighting to maximize energy savings.
The Daylighting feature prevents lights from turning ON, when the room is adequately illuminated by natural light.
NeoSwitch Dual Technology Single Relay
Occupancy Sensing Wall Switch
(Neutral Required)
EcoMeter Operation
Load 1
EcoMeter LED
OFF
ON
ON
OFF
The Walk-Through feature
maximizes energy savings by
not leaving the lights ON after
a momentary occupancy. The
sensor will switch the lights ON
when it detects a person entering
the area. If the sensor does not
continue to detect motion 20
seconds following the initial
activation, it will automatically go
to a shorter 2 minute time delay.
Coverage
The ONW-D-1001-MV-N is designed for offices up to 300 square feet.
,
8
,
8
,
10
,
15
Location
When installing the ONW-D-1001-MV-N in a new junction box, choose the switch location carefully to provide
optimum coverage of the occupied area. When replacing an existing wall switch, bear in mind that there must be a
clear line-of-sight between the sensor and the area to be covered. Avoid pointing the ONW-D-1001-MV-N directly into
the hallway where it may detect passers-by.
Action
EcoMeter
Benefit
A person enters the space and
OFF
one of the loads isactivated
The area is vacated and the
Increased awareness of energy savings;
ON
lights turn OFF automatcally
Acts as a night light locator
Increased awareness of energy savings
A person turns the lights OFF
and reminds individuals to take control
ON
manually upon exiting an area
of their lighting for additional savings;
Acts as a night light locator.
The Daylighting feature prevents the
Increased awareness of energy savings
lights from automaticallyturning ON
ON
and lets the individual know that the
when a person enters an area
Daylighting feature is working
,
36
,
20
Minor Motion, IR
Major Motion, IR
Minor Motion, Ultrasonic
Major Motion, Ultrasonic
Maximum coverage area may
vary somewhat according to room
shape and the presence of obstacles.
The NEMA WD 7 Guide and robotic
method were utilized to verify
coverage patterns.
,
20
Model # ONW-D-1001-MV-N-W
Model # ONW-D-1001-MV-N-V
Model # ONW-D-1001-MV-N-LA
Model # ONW-D-1001-MV-N-G
Model # ONW-D-1001-MV-N-B
Installation
The ONW-D-1001-MV-N can be installed in any standard single gang box. It may be
installed in the same manner as an ordinary wall switch.
• Wire the ONW-D-1001-MV-N as described in the wiring section
• Mount the ONW-D-1001-MV-N in the junction box
Wiring
CAUTION: Before installing or performing any service on a Greengate system, the power MUST be
turned OFF at the branch circuit breaker. According to NEC 240-83(d), if the branch circuit breaker
is used as the main switch for a fluorescent lighting circuit, the circuit breaker should be marked
"SWD." All installations should be in compliance with the National Electric Code and all state and
local codes.
NOTE REGARDING COMPACT FLUORESCENT LAMPS: The life of some compact fluorescent lamps (CFLs) is
shortened by frequent automatic or manual switching. Check with CFL and ballast manufacturer to determine the
effects of cycling.
1. Make sure power is turned OFF at the branch circuit breaker.
2. Wire units as shown in wiring diagrams per applicable voltage requirements.
3. Mount unit to wall box.
4. Turn power back ON at the branch circuit breaker and wait 2 minutes for the unit to stabilize.
5. Make necessary adjustments. (See Checkout and Adjustments section)
6. Install wall switch plate.
BLACK
120 to 277 VAC
Wiring Diagram 1:
120 to 277 VAC single level
single circuit wiring diagram
GREEN
GROUND
NEUTRAL
BLUE
LOAD
WHITE

Advertisement

loading

Summary of Contents for Cooper Lighting NeoSwitch ONW-D-1001-MV-N-W

  • Page 1 Installation Instructions NeoSwitch Dual Technology Single Relay Model # ONW-D-1001-MV-N-W Model # ONW-D-1001-MV-N-V Occupancy Sensing Wall Switch Model # ONW-D-1001-MV-N-LA Model # ONW-D-1001-MV-N-G Model # ONW-D-1001-MV-N-B (Neutral Required) General Information Installation Action EcoMeter Benefit EcoMeter Operation • Read all instructions on both sides of this •...
  • Page 2 (by 2 1 and 2 Coverage and sensitivity can be confirmed by watching the Cooper Lighting Solutions is a registered minute increments) or sensitivity, so there should be no need for trademark.

This manual is also suitable for:

Neoswitch onw-d-1001-mv-n-vNeoswitch onw-d-1001-mv-n-laNeoswitch onw-d-1001-mv-n-gNeoswitch onw-d-1001-mv-n-b