TECHNICAL SPECIFICATIONS Output Load MAX: 15A/125AC Input Load: 12-24VAC/DC Auto Detecting Power Supply Consumption: Relay Active: 70mA Relay Not Active: 32mA Max Applicable Power: 25VDC Operating Temperature: -40°F to 158°F 1. ACCESS THE JUMPERS & DIP SWITCHES Open the access door by sliding it to the right. See Fig 1. You can now see the jumper and dip switches.
Page 3
4. WIRE THE RECEIVER HARNESS Wire the receiver harness according to the wiring diagram (see Fig 5.) For eas of installation the wires are color coded. For most standard gate and door installations you will wire th eopen input of your gate operator or garage door, with the commona and NO (normally open) contact of either relay 1, 2 or both.
Page 4
6. WARRANTY The warranty period of this product is 24 months, beginning from the manufacturing date. During this period, if the product does not operate correctly, due to a defective component, the product will be repaired or replaced at the sole discretion of Transmitter Solutions.