Download Print this page
PA VB 450-200 Quick Start Manual

PA VB 450-200 Quick Start Manual

Unloader valve

Advertisement

Quick Links

VB 450-200/300
Pressure regulating unloader valve.
It bypasses water flow at low pressure when gun shuts off.
P/N
RATED
PRESSURE
bar - MPa
60.4020.00
200 - 20
60.4030.00
300 - 30
(1) The valve is especially designed for a constant use at a water temperature of 60°C. It can withstand up to a max.
temperature of 90°C for short intervals only.
(2) The max. pressure increase at system shut off is a percent value of calibration pressure. When it occurs, the valve is
set in operation and the whole fluid is diverted into bybass.
(3) The pressure decrease at bypass reset is a percent value of calibration pressure. It indicates the pressure drop
required for the valve to restore pressure in the system.
Instruction, Maintenance, Installation, Spare Parts Booklet.
For a correct use of the item, please follow the instructions.
Please copy all relevant information on the use and maintenance booklet of
the machine.
- Unloader Valve
60.4020.00 VB 450/200
60.4030.00 VB 450/300
-Intended for use with high flow rates
-Special steel spring with superior mechanical features, to maintain
calibration settings for longer
-Check valve specifically designed to prevent jammings
-Screw/Locknut adjusment to set maximum pressure level
-Dynamic seals with O-ring and sliding gasket
-Fixing screw slots
Technical Data
Max. Flow Rate: 450 l/min. Max. Temperature: 90°C (1)
PERMISSIBLE
MIN.
PRESSURE
ADJUSTABLE
PRESSURE
bar - MPa
bar - MPa
220 - 22
20 - 2
330 - 33
30 - 3
(2)MAX PRESS.
(3)PRESSURE
INCREASE AT
DROP AT
SYSTEM SHUT
BYPASS
OFF
RESET
%
%
10,7%
43,8%
7,8%
43,3%
Latest Update: 20/04/2018
E 258
Technical Booklet:
DN 32
1"1/4 Bsp FF
1"1/4 Bsp FF
INLET
BYPASS
OUTLET
1"1/4 Bsp FF 1"1/2 Bsp F
1"1/4 Bsp FF 1"1/2 Bsp F
n. 12.9258.00
WEIGHT
g
5950
6025
1

Advertisement

loading

Summary of Contents for PA VB 450-200

  • Page 1 Latest Update: 20/04/2018 VB 450-200/300 - Unloader Valve E 258 Technical Booklet: Pressure regulating unloader valve. It bypasses water flow at low pressure when gun shuts off. DN 32  1”1/4 Bsp FF 60.4020.00 VB 450/200  60.4030.00 VB 450/300 1”1/4 Bsp FF...
  • Page 2 This product is to be used with clean, fresh water, or water slightly additivated with ordinary detergents. For use involving harsh or even corrosive fluids, always ask PA Technical department first. Appropriate filtration should be installed when using unclean fluids.
  • Page 3 EXTRAORDINARY:every 800 hours of operation (around 20000 cycles), check conditions of seals and other internal components. If required, replace them with original PA spare parts.When installing the spares, lubrify them with waterproof grease. IMPORTANT: in case of replacement, assemble the valve correctly, resetting all conditions to starting levels and making sure to fix the nut pos.25 with thread locking liquid.
  • Page 4 60.4020.00 VB450/200 unload. 1"1/4 Bsp F 60.4220.00 VRP 450/200 reg.valv 1"1/4 Bsp F 60.4030.00 VB450/300 unload. 1"1/4 Bsp F 60.4230.00 VRP 450/300 reg.valv.1"1/4 Bsp F Pos. Description Q.ty K1K2K3K4 Pos. Description Q.ty K1K2K3K4 1 60.4014.31R Piston holder, 1"1/4 Bsp F 14 60.4007.31R Bushing 2 10.3208.28R O-ring, 2,62x36,17 mm Ni85 •...

This manual is also suitable for:

Vb 450-30060.4020.0060.4030.00