For the Householder
Your home has been fitted with a mechanical ventilation system. The system should consist of a central
mechanical extract fan, ducting, an external exhaust and extract valves in all the wet rooms e.g. the
kitchen, bathroom and toilet. The proper working of the system will provide a healthy indoor atmosphere
and will help eliminate condensation.
The Xvent 340 / Xvent 340DC system is (or can be) fitted with a 3-position switch, while the Xvent
340DCRF system is used in conjunction with a three speed wireless transmitter to set 3 different running
speeds. The high speed setting is a boost position for the extract of cooking smells or moisture-laden air,
when this is in use it is advisable to open window vents or a window to provide replacement air.
The middle position would be the normal running position in a house with the low speed position as a
background position if the house is not fully occupied. In a smaller dwelling or flat the low speed position
could be the normal running position with the middle position as a boost.
The fan is designed to run continuously 24 hours a day. It is fitted with an energy efficient electric motor.
Maintenance
In normal running the design of the fan attracts very little dirt. It may be advisable to have the unit
inspected by your installer once every 4 or 5 years and cleaned if necessary.
For the Installer
If you have any queries before installing these products or after they are installed call the Xpelair
Technical Hotline +44 (0) 8709 000430. Our engineers are there to help during normal office hours
(UK only) and may be faxed at all other times on + 44 (0) 8709 000530.
Customers outside the UK please contact your local Xpelair distributor, details of which are
available from the UK office.
Characteristics
The electric motor and fan are enclosed in the ventilator housing. Attached to the casing are 4, 125 mm
diameter spigots for ductwork connections, 3 for extract ductwork and one common spigot to take the
waste air to atmosphere.

Advertisement

loading

Summary of Contents for Xpelair 340

  • Page 1 The Xvent 340 / Xvent 340DC system is (or can be) fitted with a 3-position switch, while the Xvent 340DCRF system is used in conjunction with a three speed wireless transmitter to set 3 different running speeds.
  • Page 2: Installation

    Electrical The Xvent 340 and Xvent 340DC can be wired to run at speed 1, 2 or 3 or by use of a 3-speed switch, which gives speed choices to the user. The Xvent 340DCRF is to be wired to run at 3 speeds by use of the RF wireless control system.
  • Page 3: Wiring Instructions

    Wiring Instructions This appliance is intended for connection to fixed wiring Check that the electrical rating shown on the fan matches the mains supply. WARNING: THIS APPLIANCE MUST BE EARTHED All installations must be supervised by a qualified electrician. Installations and wiring must conform to current IEE Regulations (UK), local or appropriate regulations (other countries).
  • Page 4 Remote control – RF – Radio Frequency (868,3MHz) OPERATION: The RF system (Radio Frequency) is an installation technique that does not use any wiring between the control point(s) and the receiver. This technique is known as “remote control”. Transmission is via radio waves which makes the system ideally suited for use in specific applications such as renovation of interiors, extensions;...
  • Page 5 Customers outside UK – see international below. • UK: The Xvent 340 is guaranteed against defects for 3 years from the date of purchase. • UK: The Xvent 340DC / Xvent 340DCRF is guaranteed against defects for 5 years from the date of purchase.

This manual is also suitable for:

Xvent 340 series