DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION
RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY.
TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL
AND LOCAL ELECTRICAL/BUILDING CODES. FOR CODE INTERPRETATION, CONSULT LOCAL CODE AUTHORITY
REMOVE LOWER HOUSING:
FIXTURES WITH ONE-PIECE LOWER:
Lift lower housing hinge pins out of the hinges in the upper housing.
Slide lower housing off of hinge bar.
FIXTURES WITH POWER-PAD:
Unfasten the power-pad latch screw. NOTE: The power-pad is
HEAVY, and it should not be allowed to drop free and swing.
Disconnect the two sets of electrical connectors, and then unhook
the power-pad from the hinge bar and remove it.
!
OVER-TORQUING OF FITTER CLAMP BOLTS CAN
CREATE CRACKS IN THE HOUSING CAUSING
THE FIXTURE TO FALL TO THE GROUND.
MOUNTING / LEVELING:
Determine the size of the mast arm. This luminaire is designed to
accommodate a mast arm from 1/1/4" to 2" dia. The luminaire is
factory set to mount to the 1-1/4" arm. To mount to a 2" arm, two
modifications must be made.
1. The rear opening must be enlarged. Knockouts are cast-in
around the rear opening for this purpose. To remove this excess
material, strike with a hammer or grasp with pliers and break off.
2. The fitter bracket must be flipped over.
(This will require the complete removal of the fitter bolts.)
STANDARD MOUNTING:
Loosen (DO NOT REMOVE) the fitter bolts. Lift the luminaire into
position in front of the mast arm such that the mast arm enters
through the opening at the rear of the luminaire and between the
fitter bracket and the luminaire housing. The mast arm should rest
against one of the cast-in steps located in this area. Using these
cast-in steps, adjust luminaire to desired mounting angle. Tighten
fitter bolts to 10-12 FT/LBS.
DRAWING NO. B64877 REV E
American Electric Lighting a division of Acuity Lighting Group, Inc. Conyers, GA
(TWO BOLT LOCKING AND LEVELING)
CAUTION
LEVELING STEPS
FITTER BOLTS
KNOCKOUT
©2003 ACUITY LIGHTING GROUP, INC.
(FRONT)
WARNING
!
WARNING
!
CAUTION
!
MOUNTING / LEVELING (cont.):
CSA SPECIAL REQUIREMENTS:
Slide the weather guard onto the mast arm first. Carefully fold back the
insulating barrier along the score line to expose the fitter bolts. Install
the fixture as directed in the standard mounting instructions. Once
fixture has been installed, slide the weather guard along the mast arm
until it is firmly seated against the rear of the luminaire housing. Apply
RTV sealant between the weather guard and the housing creating a
water-tight seal. Once wiring has been completed, fold the insulating
barrier back into place.
INPUT VOLTAGE:
If the voltage available is different from that shown on the terminal block,
consult the wiring diagram for directions.
WIRING:
Feed the supply wires through the mast arm, dress them so they do not
interfere with any components, and connect them to the proper terminals
on the terminal block. Verify that supply voltage is correct as noted on
the terminal block label. Refer to the wiring diagram and the data on the
ballast for connection information and ratings.
INSTALLING LOWER HOUSING:
FIXTURES WITH ONE-PIECE LOWER:
Insert lower housing hinge pins into the hinge cradles of the upper
MAST ARM
housing. Swing the lower housing into position and press firmly upward
until latch snaps into position. NOTE: IT IS NEVER NECESSARY OR
ADVISABLE TO SLAM THE HOUSING CLOSED!
FIXTURES WITH POWER-PAD:
To install the ballastry power-pad, engage the hinge hook with the hinge
bar on the upper housing. Connect the two sets of electrical connectors
firmly together. (These connectors are "polarized" so they will only fit
together one way.) Swing the power-pad closed. Fasten the latch screw
until it is firmly seated, but DO NOT OVERTIGHTEN IT.
APPLY RTV BETWEEN
GUARD AND HOUSING
WARNING
!
ENSURE THAT ALL POWER IS
DISCONNECTED PRIOR TO WIRING
PART NUMBER 058-71-64877

Advertisement

loading

Summary of Contents for AEL 115 Series

  • Page 1 American Electric Lighting a division of Acuity Lighting Group, Inc. Conyers, GA INSTALLATION & MAINTENANCE INSTRUCTIONS 115 & 315 SERIES HORIZONTAL LUMINAIRES (TWO BOLT LOCKING AND LEVELING) WARNING DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION WARNING RISK OF FIRE.
  • Page 2 American Electric Lighting a division of Acuity Lighting Group, Inc. Conyers, GA REFLECTOR REMOVAL: LAMP INSTALLATION AND SERVICING: FIXTURES WITH POWER-PAD: Disconnect the electrical connector in Open the door to the lamp compartment by pulling forward on the latch the socket leads. located at the front of the luminaire.