Download Print this page

Radiance instruments RT616 Series Product Manual

Water resistant digital pocket thermometer

Advertisement

Quick Links

RADIANCE
INSTRUMENTS
PRODUCT
LTD.
MODEL
FEATURES:
IP67 water resistant
C/F exchangeable
Data hold function
Maximum and minimum reading memory
Stainless steel probe
Low battery indication
Temperature calibration
CE, NSF and RoHS compliant
SPECIFICATION:
Measuring range
Accuracy
Display resolution
Display reading update
Temperature response
Automatic power off
Water resistant rating
Battery
Battery life
Ambient temperature
Product size
Probe size
Reduced probe tip size
OPERATION
BATTERY INSTALLATION
1. Open the battery cap.
2. Install the battery with correct polar positioning.
3. Close the battery cap tightly.
POWER ON AND OFF
Remove the probe cover to switch on the thermometer. Insert the probe cover to switch off.
SELECT TEMPERATURE UNIT
Open the battery cover and switch C or F under the battery.
TEMPERATURE MEASUREMENT
Probe into test substance about 25mm / 1'' minimum and get the reading when it becomes stable.
DATA HOLD FUNCTION
1. Press [HOLD] to retain display reading, C or F flashing.
2. Press [HOLD] again to display normally.
MAXIMUM AND MINIMUM READING MEMORY
1. Press [MAX/MIN] to display maximum recorded reading.
2. Press the button again to display minimum recorded reading.
3. Press the button once more to display normally.
4. To reset the memory, Press and hold the button for 3 seconds until a bar "---.-" is displayed.
5. Always reset the memory once before taking new readings.
TEMPERATURE CALIBRATION
1. Press [MAX/MIN] and [HOLD] buttons together and hold about 5 seconds until display and flash "CAL" 2
seconds, then enter into the calibration mode.
2. Press [MAX/MIN] or [HOLD] to set the temperature error.
3. Press [MAX/MIN] and [HOLD] buttons together again to confirm the setting and exit the calibration mode.
*The adjustable temperature error range is -2.2~+2.2C (-4~+4F).
*You can set the temperature error in 0C or any temperature point.
PRODUCT MANUAL
Water Resistant Digital Pocket Thermometer
RT616
 RT616-150
-40~150C / -40~302F
±0.5C in -10 ~ 100C , ±1.5C rest range
±0.9F in 14 ~ 212F, ±2.7F rest range
0.1
1 second
About 8 seconds from 25 to 100C
After idle for 1 hour
IP67
3 volt, type CR2032 or equivalent x 1 piece (included)
About 5,700 hours in continuous operation
0~50C / 32~122F
155(L) x 26() mm
73(L) x 2.5(Ф) mm
17(L) x 1.6() mm
>>>>> All rights reserved <<<<<
 RT616-200
-50~200C / -58~392F -50~300C / -58~572F
NA
REV.: 4
7 AUG 2013
PAGE 1 of 2
 RT616-300
±0.5C in -10 ~ 100C ,
±2C in 200 ~ 300C
±1.5C rest range
±0.9F in 14 ~ 212F
±3.6F in 392 ~ 572F
±2.7F rest range
17(L) x 2.0() mm

Advertisement

loading

Summary of Contents for Radiance instruments RT616 Series

  • Page 1 RADIANCE PRODUCT MANUAL REV.: 4 INSTRUMENTS PRODUCT Water Resistant Digital Pocket Thermometer 7 AUG 2013 LTD. MODEL RT616 PAGE 1 of 2 FEATURES: IP67 water resistant  C/F exchangeable  Data hold function  Maximum and minimum reading memory  Stainless steel probe ...
  • Page 2 RADIANCE PRODUCT MANUAL REV.: 4 INSTRUMENTS PRODUCT Water Resistant Digital Pocket Thermometer 7 AUG 2013 LTD. MODEL RT616 PAGE 2 of 2 *The temperature error value is “0” in case of first power on or battery replacement. *For example, if the temperature error is set at -2C, all the temperature points will reduce 2C automatically. When the temperature of the object is 100C, the current temperature reading would become 98C after the temperature error of -2C was set.