Quick Links

• Always follow the Welding and General Safety Instructions included with this mold.
• Always follow the Conductor Preparation Instructions included with this mold specifi c to the connection to be made.
Ultraweld
1.
Check mold tag for conductors to be welded and proper
weld metal cartridge size to use.
2.
Make sure all surfaces and conductors are clean, dry and are
the proper sizes for the mold's application per mold tag.
3.
For the initial connection, torch dry the mold with a hand
operated propane torch.
4.
Position mold onto conductor(s). See front of the other
instruction sheet included with this mold for positioning
of conductors into mold. Lock mold with handle clamps
or frame, which ever is the case. Note that Handle Clamp
adjustments may be made by removing adjusting screw and
turning eye bolt 180° clockwise to tighten or 180° counter
clockwise to loosen.
5.
If using UltraShot
, drop the weld metal cartridge into the
®
mold with the igniter exiting the mold through the slot in the
top of the mold. Ensure the lid is closed tightly.
Note: UltraShot
weld metal US500, US750, US1000 and
®
US1500 are made up of two or three cartridges. To use,
cartridge(s) without an igniter should be dropped into the
mold fi rst. The cartridge with an igniter should be on top
and should be exiting the mold through the slot in the top of
the mold. Ensure the lid is closed tightly.
Step 5
Revised 7.9.12
Instructions
UltraShot
®
Step 5 Notes
UltraShot
Welding Procedures
®
6a. Before igniting, verify conductor positioning and that mold is
closed completely.
6b. Slide the igniter lead connecter over the end of the igniter.
Push connector until the igniter bottoms out inside the
connector.
6c. Simultaneously push and hold both buttons on the side of
the USCONTROLLER until the reaction is initiated and then
release the buttons. Note that the LED light on the side
of the USCONTROLLER will illuminate while both buttons
are pressed. Do not hold buttons for more than 5 seconds.
Should the reaction not occur, wait 30 seconds and remove
the UltraShot
cartridge and insert another cartridge. If it
®
fails to ignite again, it is likely that the controller needs to be
recharged.
6d. After ignition, remove igniter lead immediately.
301 Ziegler Drive, Grayslake, IL 60030
Phone: 847-548-8700
Fax: 847-548-8755
Website: www.harger.com
®
1

Advertisement

loading

Summary of Contents for Harger Ultraweld UltraShot US500

  • Page 1 Ensure the lid is closed tightly. 6d. After ignition, remove igniter lead immediately. Step 5 Step 5 Notes 301 Ziegler Drive, Grayslake, IL 60030 Phone: 847-548-8700 Fax: 847-548-8755 Website: www.harger.com Revised 7.9.12...
  • Page 2 Ultraweld UltraShot Welding Procedures ® ® Continued To clean the mold, use a MCBRSH1 natural bristle brush be- 7a. If using Ultraweld tubes, insert disk in the bottom of the fore making next weld. On horizontally split molds, use end mold crucible, concave side up.

This manual is also suitable for:

Ultraweld ultrashot us750Ultraweld ultrashot us1000Ultraweld ultrashot us1500