Download Print this page

Advertisement

Quick Links

This guide is intended to provide basic information required in order to set-up a drive to run a motor.
Please refer to the Unidrive M200 / M201 User Guide which is available to download from
www.controltechniques.com/userguides.
1
Safety information
This guide does not include safety information. Incorrect installation or operation of the
drive, could cause personnel injury or equipment damage. For essential safety
information, please refer to the Unidrive M200 / M201 User Guide or the safety booklet
supplied with the drive.
WARNING
2
Product information
2.1
Ratings
Input
phases
Model
current
ph
01100017
1
01100024
1
01200017
1
01200024
1
01200033
1
01200042
1
02100042
1
02100056
1
02200024
1 / 3
5.3/4.1
02200033
1 / 3
8.3/6.7
02200042
1 / 3
10.4/7.5
02200056
1 / 3
14.9/11.3
02200075
1 / 3
18.1/13.5
02400013
3
02400018
3
02400023
3
02400032
3
02400041
3
03200100
1 / 3
23.9/17.7
03400056
3
03400073
3
03400094
3
04200133
1 / 3
04200176
3
04400135
3
04400170
3
The nominal cable sizes shown in the table above, are provided as a guide only. Ensure
NOTE
that the cables used conform to the local wiring regulations.
Unidrive M200 /M201 Quick Start Guide
Issue Number: 1
Unidrive M200, M201
Quick Start Guide
Max input
fuse rating
Max.
cont
input
1 Ph
3 Ph
A
A
A
10
16
6
6
10
16
18.8
20
24
25
6
6
10
10
16
10
20
15
20
15
2.4
6
2.9
6
3.5
6
5.1
6
6.2
10
25
20
8.7
10
12.2
16
14.8
16
25
20
25
20
25
Nominal cable size
European
USA
Input
Output
Input
2
2
AWG
mm
mm
1
1
16
1
1
14
1
1
16
1
1
16
1
1
16
1
1
16
2.5
1
12
4
1
10
1
1
16
1
1
16
1
1
16
2.5/1.5
1
12/14
2.5
1
12
1
1
16
1
1
16
1
1
16
1
1
16
1
1
16
4
1.5
10/12
1
1
14
1.5
1
12
2.5
1.5
12
4/2.5
2.5
10
4
2.5
10
2.5
2.5
10
4
2.5
10
Output current
Max.
cont
Nominal
Output
output
power
current
AWG
A
kW
16
1.7
0.25
16
2.4
0.37
16
1.7
0.25
16
2.4
0.37
16
3.3
0.55
16
4.2
0.75
16
4.2
0.75
16
5.6
1.1
16
2.4
0.37
16
3.3
0.55
16
4.2
0.75
16
5.6
1.1
16
7.5
1.5
16
1.3
0.37
16
1.8
0.55
16
2.3
0.75
16
3.2
1.1
16
4.1
1.5
14
10
2.2
16
5.6
2.2
16
7.3
3
14
9.4
4
12
13.3
3
12
17.6
4
12
13.5
5.5
12
17
7.5
Motor
power
hp
0.33
0.5
0.33
0.5
0.75
1
1
1.5
0.5
0.75
1
1.5
2
0.5
0.75
1
1.5
2
3
3
3
5
3
5
7.5
10
1

Advertisement

loading

Summary of Contents for Unidrive M200

  • Page 1 Quick Start Guide This guide is intended to provide basic information required in order to set-up a drive to run a motor. Please refer to the Unidrive M200 / M201 User Guide which is available to download from www.controltechniques.com/userguides. Safety information This guide does not include safety information.
  • Page 2 6 - 690 V (500 - 690 ± 10 %) Mechanical installation The drives can be panel mounted with 0 mm space between the drives. For further information on mechanical installation refer to the Unidrive M200 / M201 User Guide. 11 mm (0.43 in) Cover release...
  • Page 3 (6) The Escape key is used to exit from the parameter edit / view mode. (7) The Speed ref pot is used to control the speed reference in keypad mode (only on Unidrive M201). Unidrive M200 /M201 Quick Start Guide...
  • Page 4 To stop the motor under ramp control, open either the run forward or Stopping run reverse terminal. If the enable terminal is opened while the motor is running, the motor will coast to a stop. 0478-0038-01 Unidrive M200 / M201 Quick Start Guide Issue Number: 1...

This manual is also suitable for:

M2010110001701100024012000170120002401200033 ... Show all