Hélicoptères Guimbal
CABRI G2
Parameter
LOW FUEL
(2.6 U.S. gal)
BATT
Battery
charge
EPM Alarms
Alarm
Signification
CO
Amber
MGB / TGB
Chips
Amber
Fire
compartment
Red
3-14
Exceeds
Display in
Check with LOW FUEL warning light
Red
10 L
Check ALT switch ON.
Battery is not being charged. Turn all non-
essential equipment OFF.
Yellow
Caution : Prolonged flight without alternator
can result in loss of electronic and electrical
equipments.
1. Shut cabin heater OFF
Carbon
2. Open vents
monoxide
3. Ground or hover : change heading
cabin
4. If symptoms of CO poisoning (headache,
pollution
If alarm is accompanied by any indication of
a problem such as noise, vibration or MGB
Gearbox
temperature light,
degradation
If there is no other indication of a problem,
Engine
Refer to procedure page 3-6
fire
EASA Approved
EMERGENCY PROCEDURES
Corrective actions
If ON :
LAND IMMEDIATELY
LAND AS SOON AS POSSIBLE
Corrective actions
drowsiness, dizziness) accompany light,
LAND IMMEDIATELY
LAND IMMEDIATELY
LAND AS SOON AS POSSIBLE
LAND IMMEDIATELY