Electrical Fire - Guimbal CABRI G2 Flight Manual

Hide thumbs Also See for CABRI G2:
Table of Contents

Advertisement

Hélicoptères Guimbal
CABRI G2

Electrical fire

Can be detected by a strong smell of burning and/or by smoke.
1.
Switch alternator OFF,
2.
Switch MASTER OFF,
Note : EPM and NR lights are no longer powered.
3.
Move NR switch to "Backup" position,
4.
Use NR lights (Backup position) to monitor rotor speed.
Note : Remaining electrical equipment are those on direct battery : BARC
backup and ignition system. Refer to page 7-7 for electrical system
description.
If fire source is determined, switch the other systems ON
If electric fire continues,
If not,
LAND AS SOON AS POSSIBLE.
Notes :
• With MASTER and alternator both OFF, engine still operates with
both ignitions, but without the governor.
• With MASTER OFF and NR switch on "Backup", following lights are
still operative :
Original issue
Issue 09.3
LAND IMMEDIATELY.
High, Normal and Low NR,
LOW FUEL caution.
EASA Approved
EMERGENCY PROCEDURES
SECTION 3
3-7

Advertisement