H2O USRO4-50-JG Installation And Service Manual

Reverse osmosis system with quick connect fittings

Advertisement

Quick Links

Installation and Service Guide
Reverse Osmosis System with Quick-Connect Fittings
USRO4-50-JG / USRO4-60-JG / USRO4-100-JG
USRO5-50-JG / USRO5-60-JG / USRO5-100-JG
Please read this manual carefully
before attempting installation

Advertisement

Table of Contents
loading

Summary of Contents for H2O USRO4-50-JG

  • Page 1 Installation and Service Guide Reverse Osmosis System with Quick-Connect Fittings USRO4-50-JG / USRO4-60-JG / USRO4-100-JG USRO5-50-JG / USRO5-60-JG / USRO5-100-JG Please read this manual carefully before attempting installation...
  • Page 2 SYSTEM AND FAUCET DIAGRAM How to make a Quick-Connect Connection Insert tube 1. Fitting grips before it seals. Ensure tube is pushed into the tube stop. 2. Push the tube into the fitting, to the tube stop. The collet (gripper) has stainless steel teeth which hold the tube firmly in position while the O-ring Push up to tube stop provides a permanent leak-proof seal.
  • Page 3 Your Reverse Osmosis (RO) System has been tested in your tubing and gently push in the tubing until it will not to ensure it will operate correctly. The following periodic go any further. To ensure that your tubing has made a snug maintenance is recommended so your system will provide fit, pull back gently on the tubing;...
  • Page 4: Unit Preparation

    and on the vertical or horizontal tailpiece. Do not install the hole. drain saddle near a garbage disposal to avoid clogging the 2. Drill the pilot hole drain line with debris. 3. Continue to enlarge hole with larger size drill bit until it is 1/2”.
  • Page 5 4. Drain Saddle Valve Installation (See Figure 3) A Drain Saddle is used to make a wastewater connection with the drain under the sink, which is designed to fit around a standard 1-1/2” OD drainpipe. The drain saddle valve should always be installed before (above) the p-trap and on a vertical or horizontal drain.
  • Page 6: System Start-Up

    inside freezer prior to turning off the existing tap water 7. RO Unit Installation supply line to the refrigerator. Turn on the icemaker after the RO system has been drained several times and the The RO unit is normally mounted to the right or left sink tank has a full supply of water.
  • Page 7: Troubleshooting

    2. Turn off water feed with angle stop valve. Troubleshooting 3. Open RO faucet to relief pressure. 4. Using the supplied housing wrench remove the filter RO Systems are highly sensitive to pressure and housing. temperature. RO Membranes always perform better under 5.