Download Print this page

Unisen StarTrac E-Spinner Replacement Instructions Manual

Heart rate board

Advertisement

Quick Links

E-Spinner Heart Rate Board Replacement Instructions
1- Gather the following items:
-
New heart rate board (P/N:740-7008)
-
3/16 Allen key (not provided)
-
Philips-head screw driver (not
provided)
2- Using a Philips-head screw driver,
remove the two screws holding the
bracket to the neck.
(Save the screws for future use)
3- Pull on the height adjustment lever of
the neck to free it, then pull the neck all
the way out of the base.
(Be cautious not to cut any of the cables
in the process)
STAR TRAC BY UNISEN CONFIDENTIAL AND PROPRIETARY
New heart
rate board
Figure 1: Heart rate board replacement tools
Remove
screws
Figure 2: Removing neck bracket screws
Figure 3: Disassembling the neck
3/16
Philips-head
Allen key
screw driver
620-7900 REV A
Page 2 of 8

Advertisement

loading

Summary of Contents for Unisen StarTrac E-Spinner

  • Page 1 (Be cautious not to cut any of the cables in the process) Figure 3: Disassembling the neck 620-7900 REV A STAR TRAC BY UNISEN CONFIDENTIAL AND PROPRIETARY Page 2 of 8...
  • Page 2 6- Using a Philips-head screw driver, remove the 12 screws holding the back plastic cover of the display in place. Remove screws Figure 6: Removing back cover screws 620-7900 REV A STAR TRAC BY UNISEN CONFIDENTIAL AND PROPRIETARY Page 3 of 8...
  • Page 3 Figure 8: Removing fan assembly screw 9- Lift top fan assembly to release the heart rate cable from underneath the fan assembly. Figure 9: Releasing heart rate cable 620-7900 REV A STAR TRAC BY UNISEN CONFIDENTIAL AND PROPRIETARY Page 4 of 8...
  • Page 4 Figure 11: Detaching old heart rate board 12- Peal the protective film off of the new heart rate board’s adhesive tape. Figure 12: Pealing new heart rate board’s protective film 620-7900 REV A STAR TRAC BY UNISEN CONFIDENTIAL AND PROPRIETARY Page 5 of 8...
  • Page 5 Figure 14: Routing new heart rate cable 15- Slide the Fitlinxx connector back onto to the base of the plastic cove. Figure 15: Installing Fitlinxx connector 620-7900 REV A STAR TRAC BY UNISEN CONFIDENTIAL AND PROPRIETARY Page 6 of 8...
  • Page 6 Figure 17: Installing metal bracket 18- Reconnect all 4 cables coming out of the neck: The Coax cable Ground wire Power cable Data cable Figure 18: reconnecting display cables 620-7900 REV A STAR TRAC BY UNISEN CONFIDENTIAL AND PROPRIETARY Page 7 of 8...
  • Page 7 19- Insert the display/neck assembly back in the bike frame and secure the bracket with the two screws saved from step 2. Figure 19: The heart rate board replacement is now completed. 620-7900 REV A STAR TRAC BY UNISEN CONFIDENTIAL AND PROPRIETARY Page 8 of 8...