Ziegra PE‐3 UV filter  
Main Features
• 
Kills 99.9% of micro‐organsims 
• 
Significantly slows down colonisa on of ice the machine by bacteria 
• 
Enviromentally friendly technology with no disinfec on by‐products. 
• 
Works 24/7 to protect the water supply 
• 
Low running costs 
• 
Fast ac ng, allows full flow without the need for tanks or reac on  mes 
• 
Stainless steel reactor vessel for high resistance to corrosion and improved hygiene 
• 
Conserves water, the UV process does not waste any water 
• 
Low energy consump on 
Specifica ons
Model: Ziegra PE‐3 UV Filtra on Unit 
Part number: ZUK9700055  
Models applicable: All granular flake and nugget ice machines 
Water: Mains water 
Construc on: Stainless Steel 
Max. flow rate 0.7m³ per hour  
Power consump on 22W  
Water inlet: 1/2" BSP male 
Water outlet: 1/2" BSP male 
Pressure range: 2 ‐ 6 bar 
Temperature range: 5°C to 40°C 
Dimensions (reactor): 350mm x ø65mm 
 Packed dimensions: 106 x 106 x 600mm 
Packed weight: 3.0kg 
Kit includes: Stainless steel reactor vessel, 1 Pair reactor moun ng brackets, QS370 quartz sleeve (pre‐
fi ed), E330LS UV lamp (17W), Power supply. 
Never operate the UV lamp out of the chamber. Never look at the 
opera ng UV lamp without eye protec on. 
1 of 6
Ziegra ‐ UV Filtra on 

Advertisement

loading

Summary of Contents for Ziegra PE-3

  • Page 1 Ziegra ‐ UV Filtra on  Ziegra PE‐3 UV filter   Main Features •  Kills 99.9% of micro‐organsims  •  Significantly slows down colonisa on of ice the machine by bacteria  •  Enviromentally friendly technology with no disinfec on by‐products.  •  Works 24/7 to protect the water supply  •  Low running costs  •  Fast ac ng, allows full flow without the need for tanks or reac on  mes  •  Stainless steel reactor vessel for high resistance to corrosion and improved hygiene  •  Conserves water, the UV process does not waste any water  •  Low energy consump on  Specifica ons Model: Ziegra PE‐3 UV Filtra on Unit  Part number: ZUK9700055   Models applicable: All granular flake and nugget ice machines  Water: Mains water  Construc on: Stainless Steel  Max. flow rate 0.7m³ per hour   Power consump on 22W  ...
  • Page 2: Installation Cautions

    Ziegra ‐ UV Filtra on  Installa on  INSTALLATION CAUTIONS  1.  UV disinfec on devices are designed to be installed on the cold water line only.  2.  Install the UV disinfec on system indoors in a protected area where the temperature does not fall  below 4°C and the humidity level is low (to prevent condensa on on the reactor chamber). This  unit func ons op mally between 9°C and 29°C.  3.  Use PTFE tape on all plumbing connec ons. Do not use other sealants.  Gloves before installa on  The kit comes securely packaged in a cardboard box, open  carefully to make sure you don’t damage the contents.  The kit contains: Stainless steel reactor tube, 1 pair reactor  moun ng brackets, Quartz sleeve, ballast controller box,  moun ng screws.  Select a suitable loca on in a dry well lit area, which provides  enough room to perform rou ne maintenance for the  disinfec on system and its related components. UV system  should always be located closest to the point of use. The system  can be installed either horizontally or ver cally although ver cal  is preferred. When selec ng a moun ng loca on, you must also ...
  • Page 3 Ziegra ‐ UV Filtra on  Mount the ballast controller horizontally on the wall using the  supplied fi ngs either above or to the side of the reactor  chamber. Ideally place the controller above the reactor and  away from any water connec on point to prevent water  leaking on to the controller. Never mount the controller  ver cally with AC connector at the top of the controller to  prevent moisture from running down the cord and causing a  poten al fire risk. Make sure you form a ‘drip loop’ in the  power cord to prevent water from entering the ballast  controller.  In order to op mise the UV radia on, please make sure the UV  bulb is clean before installa on. Clean with alcohol to remove  any marks that are visible.  The spring and quartz sleeve are already installed installed in  the reactor. Remove the ‘window’ from the end nut carefully  making sure to retain the spring in the quartz sleeve.  Cau on: Quartz sleeve and bulb are easily damaged. Please  handle with care.  Carefully insert the UV lamp into the Quartz sleeve through the  nut.  Remove the cable gland nut from the cover cap.  This will free the electrical socket from the cover cap.  3 of 6...
  • Page 4 Ziegra ‐ UV Filtra on  Back the cover cap down the cable a li le to give yourself some  space to work.  Connect the electrical connector to the socket on the end of the  bulb. This may require some force so please be careful with the  bulb at this stage.  Slide the cover back into posi on making sure it slides fully into  posi on.  Tighten the thumbscrew to lock the cover back on to the reactor  end nut.  Re‐fit the cable gland nut to the cover cap.  When all the plumbing connec ons are made, slowly turn on the water and check for  leaks.   Allow the water to run for a few minutes to clear any air or dust that may be in the  reactor.  Connect the power for start‐up.  Do not remove the UV lamp from the chamber when applying electrical power.  This system is designed for con nuous opera on and frequent switching will reduce the  UV radia on and service life. Do not electrically cycle the UV unit more than three on/off  cycles in any 24 hour period.  4 of 6...
  • Page 5 Ziegra ‐ UV Filtra on  Plumbing Disinfec on Procedure  The following disinfec on procedure is generally accepted as being suitable for the  disinfec on of plumbing systems known to be contaminated. If you are uncertain about  the effec veness of this procedure you are advised to contact your local health authority  responsible for water safety.  During the UV disinfec on process, the only place disinfec on takes place is within the  reactor chamber. There is no residual disinfectant capacity. Therefore it is necessary to  chemically disinfect the plumbing system prior to the ini alisa on of the UV system.  1.  Turn the UV system shut off valves to the closed posi on.  2.  The disinfec on of the plumbing system is most readily accomplished by removing the  5 micron pre‐filter cartridge and adding 250 ‐ 500ml of a standard 5% concentra on of  unscented household bleach into the empty filter housing and re‐a aching.  3.  Verify that the UV system is connected to the AC power voltage and opera ng  properly.   4.  Turn the valves to the open posi on and let the water flow.   5.  Run water through the system un l you can easily smell the chlorine, catching the run  off water in a tub. Close the valves and let the system sit for 30 ‐ 60 mins.   6.  Close the valves on the UV system. Open the valves and flush the system through ...
  • Page 6 Ziegra ‐ UV Filtra on  6 of 6...

This manual is also suitable for:

Zuk9700055