Download Print this page

Vermont Castings ST208 Instructions Manual

Fuel conversion kit for intrepid direct vent gas stove

Advertisement

Quick Links

Fuel Conversion Kit
Instructions
for Intrepid Direct Vent Gas
Stove
Kits:
Natural to LP: 20012921
LP to Natural: 20012910
WARNING!
The installation of this conversion kit must only
be undertaken by a qualified gas appliance
installer.
This kit is designed for conversion of the Intrepid Direct
Vent Gas Stove Models INDVR Series.
Tools required: 5/32" (4 mm) Allen wrench, 3/8" and
1/2" open end wrenches, needlenose pliers.
Kit contents: Pilot orifice, injector orifice, conversion
label.
Conversion Precautions
Allow unit to cool completely before beginning conver-
sion. Before proceeding, turn control knob on valve to
OFF and turn gas supply to OFF. Turn OFF any electric-
ity that may be going to the appliance.

Conversion Procedure

1. Remove stove front. Lift stove front up and then
swing bottom out and away to disengage from the
stove body. (Fig. 1)
2. Undo the right and left latches at the top of the glass
frame. (Fig. 2)
3. Pull the top edge of the glass and frame assembly
away from the firebox face. Place the assembly out
of the way on a flat, padded surface such as a coun-
ter protected by a towel.
4. Remove the logset from the firebox.
Fig. 1 Remove the stove front. (Top vent shown)
Fig. 2 Release the latches to remove the glass frame.
Valve Conversion
1. Turn control knob to the OFF position, and shut off
the gas supply to the valve.
2. Allow the valve to cool to room temperature.
3. Remove the black protection cap by hand. (Fig. 3)
4. Insert a 5/32" or 4 mm Allen wrench into the hexago-
nal key-way of the screw (Fig. 4), rotate it counter-
ST208
clockwise until it is free and extract it.
glass swivel latch
12/99
Figure 3
�����
������ �����
����
ST967
ST967
Intrepid install front
7/07
ST208
Figure 4
�����
����� ������
20012973 7/07 Rev. 0
����

Advertisement

loading

Summary of Contents for Vermont Castings ST208

  • Page 1: Conversion Procedure

    3. Remove the black protection cap by hand. (Fig. 3) 4. Insert a 5/32” or 4 mm Allen wrench into the hexago- nal key-way of the screw (Fig. 4), rotate it counter- ST208 clockwise until it is free and extract it. glass swivel latch...
  • Page 2: Gas Conversion

    5. Check that the screw is clean and if necessary re- move dirt. 6. Flip the screw. (Fig. 5) 7. Using the Allen wrench as shown in Figure 6, rotate the screw clockwise and tighten until snug. Figure 5 WARNING: Do not overtighten the screw. Recommended to grip the wrench by the short side.
  • Page 3 • Remove pilot orifice with needlenose pliers. (Fig. 12) NOTE: Use a wrench to hold pilot tube in place while removing the orifice. • Install the conversion orifice. • Reinstall pilot hood and tighten until mark on pilot hood aligns with mark on pilot bracket. CO144 Fig.
  • Page 4 3. Reinstall logs. a. Install the rear log by mating the notch on the bot- tom of the log with the raised notch on the back left side of the ember bed. (Fig. 17) Ensure the cutout in the right side of the log is sitting around the pilot assembly and pilot is not obstructed.
  • Page 5 Figure 18 Left Log Figure 19 Left Log 20012973 Rear Log ����� ���������� ���� ���� Ember Bed ����� ����� ���� �������� ���� Right Log LG494 Top Log Right Log LG495...
  • Page 6 Kit # 20012921 Kit # 20012910 Table 2. Injector Orifice Size Matrix Conversion to LP Orifice Part # Minimum #56 (.0465”) 30000336 Conversion to Natural Gas Orifice Part # Minimum #47 (.0785”) 20003054 Input (BTU/h) Maximum 12,000 16,000 Input (BTU/h) Maximum 12,500 18,500...
  • Page 7 20012973...
  • Page 8 CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www.cfmcorp.com 20012973...

This manual is also suitable for: