CORN & PELLET MULTIFUEL STOVE
Installation - Operation - Maintenance Instructions - Repair Parts
READ THIS ENTIRE MANUAL, THOROUGHLY, BEFORE ATTEMPTING TO INSTALL AND/OR
BURN YOUR NEW AMERICAN HARVEST CORN AND PELLET MULTI-FUEL STOVE. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURIES
Safety Notice: If this stove is not properly installed, a house fire may result.
For your safety, follow the installation directions. Contact local building or fire officials
about restrictions and installation requirements peculiar to your area. Do Not Plug
this appliance into an electrical outlet before reading and understanding all operations
and always unplug the unit before attempting any work or maintenance. Do not
connect this stove to any chimney flue already serving another appliance. Carefully
observe and maintain all clearances to combustibles.
A note about fuel: Use only dried shelled corn with a moisture content of 14%
or less (11 to 12% provides the best results); any pellet fuel used should have
an ash content of 1% or less. If not, efficiency will suffer, and your warranty may be
voided.
Your American Harvest Corn/Pellet Stove operates on a negative pressure. Therefore,
all venting connections (elbows, T-pipe) must be sealed and airtight.
Use Hi-Temp silicone at each joint or connection.
UNITED STATES STOVE COMPANY GRANTS NO WARRANTY, IMPLIED OR STATED,
FOR THE INSTALLATION OR MAINTENANCE OF THE STOVE AND ASSUMES NO
RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).
UNITED STATES STOVE COMPANY - 227 INDUSTRIAL PARK ROAD-SOUTH PITTSBURG, TN. 37380
USSC
K e e p i n g
K e e p i n g
K e e p i n g
K e e p i n g
K e e p i n g
North
North
North
North
North
America
America
America
America
America
Since
Since
Since
Since
Since
6039, 6039T
OWNER'S MANUAL
OR EVEN DEATH.
SAVE THESE INSTRUCTIONS
TECHNICAL ASSISTANCE (423) 837-2100 - (423) 837-2109 FAX
W
W
W arm
W
W
arm
arm
arm
arm
1869
1869
1869
1869
1869
851621B
1

Advertisement

Table of Contents
loading

Summary of Contents for United States Stove American Harvest 6039

  • Page 1 UNITED STATES STOVE COMPANY GRANTS NO WARRANTY, IMPLIED OR STATED, FOR THE INSTALLATION OR MAINTENANCE OF THE STOVE AND ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S). UNITED STATES STOVE COMPANY - 227 INDUSTRIAL PARK ROAD-SOUTH PITTSBURG, TN. 37380 TECHNICAL ASSISTANCE (423) 837-2100 - (423) 837-2109 FAX USSC...
  • Page 2: Specifications

    We strongly suggest installing smoke detectors in your home if not already installed. Initial burn off may cause slight smoke and odor the first few hours of operation. United States Stove Company Stove) reserves the right to alter products, specifications and price without notice.
  • Page 3 6. After all bolts and screws have been tightened properly, set the heater back up on the legs and replace the two ash dump covers. (See pg. 15 for ash dump cover placement) USSC 6039&6039T ASSEMBLY 1. The Auger is packed in the hopper and must be installed properly as illustrated below.
  • Page 4: Safety Steps

    IMPORTANT: Proper installation of this stove is necessary for safe and efficient operation. Installing this product improperly may result in a house fire and personal injury. All applicable building codes for your location must be followed. In areas where building codes require additional steps to the installation of this product not included in this manual the building codes will take precedent and must be followed.
  • Page 5: Installation Requirements

    BURNING SOLID FUELS SHELLED CORN • Corn must contain less than 14% moisture content. Wet corn will rapidly deteriorate stove components, reduce efficiency and void all warranties. Purchase a moisture tester if in doubt. • Corn must be clean and free from debris. Never burn corn right from the field. Damage caused by dirty corn is not covered by the product warranty.
  • Page 6: Clearances To Combustibles

    CLEARANCES TO COMBUSTIBLES The stove must be installed with the following minimum clearances to side and back wall combustible materials. NOTE: These are minimum clearances to combustible walls established by the testing lab. The amount of room needed on the left side of the unit to access the electrical panel is (6) six inches (152mm).
  • Page 7: Guidelines For Exhaust Venting Systems Design

    GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN It is recommended that only an authorized installer install your pellet/corn stove, preferably an NFI certified specialist. The following installation guidelines must be followed to ensure conformity with both the safety listing of this stove and to local building codes.
  • Page 8 DESIGN GUIDELINES FOR OUTSIDE COMBUSTION AIR CONNECTION For installations with horizontal through-the-wall exhaust, it is strongly recommended that the stove combustion air be connected to the outside. If the home is newer or has been tightly insulated it is required to install outside combustion air.
  • Page 9: Installation Configurations

    Note: Where passage through a wall, or partition of combustible construction is desired, the installation shall conform to CAN/CSA -B365 The American Harvest Corn/Pellet Stove Model 6039/6039T may be installed as follows: 1) A freestanding unit MOBILE HOME INSTALLATION REQUIREMENTS...
  • Page 10 Note: Always check dimensions on unit before cutting hole in wall 3’ Minimum Vertical Pipe 6039 - PEDESTAL UNIT 6039T - LEG UNIT COMBUSTION COMBUSTION EXHAUST OUTLET EXHAUST OULET 10 1/16 10 1/16 AIR INTAKE AIR INTAKE 3' DIA 3" DIA.
  • Page 11 6” Min. The Hearth Pad is not required under the unit if the floor is noncombustible but is required 6 inches (152mm) beyond the front of the unit and 6 inches (152mm) beyond each side of the door if the floor is a combustble floor. wood flooring, carpet, linoleum, etc.
  • Page 12: Cleaning The Glass

    GLASS MAINTENANCE, REMOVAL AND REPLACEMENT Your American Harvest Corn/Pellet Stove comes to you with the glass door installed in place, ready for use. The glass is surrounded on the edges with a gasket and seated in a glass channel. It is held in place with four (2) clips. REMOVAL OF BROKEN OR DAMAGED CERAMIC GLASS Open the door and lift off of hinges.
  • Page 13: Lighting Instructions

    LIGHTING INSTRUCTIONS CAUTION: DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. Before lighting your American Harvest for the first time, make sure that all items are out of the hopper, ash pan and firebox area.
  • Page 14: Maintenance Instructions

    Disposal of Ashes Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have been thoroughly cooled.
  • Page 15: Automatic Safety Features

    Weekly Maintenance • Shut down the stove as directed in the operating instructions. Allow the stove to cool to room temperature. Remove the small clean-out slides in the lower corners of the firebox. Tap the sides of the burn chamber with a wooden stick. Do not tap the firewall behind the burn box as it may damage the insulation.
  • Page 16: Circuit Board Functions

    CIRCUIT BOARD FUNCTIONS Once the control panel is turned to on, a timer begins that will start, stop and continue operation of the American Harvest as a preset temperature is achieved. COMPONENT Exhaust Blower Agitator Auger Room Fan Automatic Shutdown Normal Operation Adjusting the Air/Fuel Mixture The two adjustments necessary for proper air/fuel mixture are the combustion air/blower setting and the auger run time setting.
  • Page 17 CIRCUIT BOARD FUNCTIONS Once the AMERICAN HARVEST has reached the normal operating temperature and switched to the “OFF” position, the unit will continue to operate on a much lower setting for 10 minutes. (Approximately half of the “1” setting). After 10 minutes the auger will slow down further and continue at this feed rate until the AMERICAN HARVEST “LOW LIMIT SAFTEY”...
  • Page 18: Troubleshooting

    Unplug stove before performing any maintenance PROBLEM ? Fire burns with a lazy, orange flame and/or fuel builds up in the firepot. Glass may become dirty. ? Fire goes out or stove shuts down. Fuel may stop feeding. ? Fire goes out or stove shuts down. Fuel may stop feeding.
  • Page 19: Wiring Diagram

    WIRING DIAGRAM USSC...
  • Page 20: Repair Parts Diagram

    REPAIR PARTS DIAGRAM-6039 USSC...
  • Page 21: Repair Parts List

    80461 USSC REPAIR PARTS LIST-6039 DESCRIPTION Feed Door Assembly Latch, Door Pedestal (6039) Pedestal Bottom Weldment (6039) Pedestal Back (6039) Ash Pan Weldment (6039) Handle, Brass Corner, Trim (6039) Pedestal Trim, Front (6039) Pedestal Trim, Right (6039) Pedestal Trim, Left (6039)
  • Page 22 Part No. Descritption 25491 Feed Door 25492 Handle, Door 83506 Roll Pin, 3/8 x 1-1/4 88112 Gasket, 1/2” Sq. Rope 88087 Gasket, Glass (1 x 3/16) 891131 Glass Ceramic 6039T Parts Diagram & List NOTE: For internal parts, cabinet parts, etc. see pages 21-22 Part No.
  • Page 23 Notes USSC...