Download Print this page

Ultra Products ULT33062 Features

Uninterrupted power supply (ups)

Advertisement

Quick Links

Uninterrupted
Power Supply (UPS)
The Ultimate Power Protection!
If you're looking for the most complete, technologically advanced power protection
unit for the money, the Ultra UPS line is exactly what you need. An Ultra UPS is an
absolute must for anyone running a small server, workstation or a powerful PC. We're
so confident that our UPS will offer you ultimate power protection, it carries a
$125,000 guarantee against damage to any equipment connected to the UPS. You
simply cannot afford to cut corners when it comes to safeguarding your valuable
equipment, and these UPS's deliver the comprehensive protection for computer,
peripherals and data files at a remarkably low price.
Features
- AVR (Automatic Voltage Regulation)
- Fully Digitized Microprocessor Controlled
- Protects up to 4 Devices at Once
- Energy Saving Function (UPS Green Mode)
- 50/60Hz Frequency Auto Sensing and Selection
- USB Communication Port
- Advanced Battery Management (ABM Technology)
300VA
Gneral
Sku
ULT33061
Backup Time
4-6 minutes (a PC with 15" CRT monitor)
8-12 minutes (a PC with 15" LCD monitor)
Net Weight Kg (lbs)
1.9(4.2)
Digital Display
No
Output
Watts
150
UPS Capacity
300VA
No. of Sockets
Style A UPSx3, Bypassx3
Voltage (Battery)
Simulated sine wave at 120V +/- 5%
Frequency (Battery)
50 or 60Hz +/- 0.3Hz
Transfer Time
2-4 milliseconds, including detection time
Input
Voltage (Single Phase)
120V +15%/-20% at line input
Frequency
50 or 60Hz +/- 10% (auto sensing)
Protection
Unit Input
Circuit breaker for overload & short circuit protection
Overload Protection
AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously.
Backup Mode: If load exceeds 110% of nominal for 1
second, UPS shuts down automatically.
Short Circuit
UPS output shuts off immediately
Surge Protection
1140 Joules, 2ms
Battery
Type
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
Typical Recharge Time
4 hours (to 90% of full capacity)
Protection
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Interface
USB
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Alarm
Battery Backup
Slow beeping sound every 4 seconds
Battery Low
Rapid beeping sound every second
Abnormal Charge
AC Mode: Rapid beeping sound every 0.5 second
Overload
Continuous beeping sound
Environment Ambient Operation
3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?
Audible Noise
<40dBA (1 meter from surface)
Includes

UPS Monitoring

Software
500VA
ULT33062
7-9 minutes (a PC with 15" CRT monitor)
14-16 minutes (a PC with 15" LCD monitor)
2.58(5.67)
No
250
500VA
Style A UPSx3, Bypassx3
Simulated sine wave at 120V +/- 5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously. If load exceeds 120% of nominal for
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automatically.
UPS output shuts off immediately
1140 Joules, 2ms
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continuous beeping sound
3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?
<40dBA (1 meter from surface)
1-800-830-0051
www.ultraproducts.com
700VA
ULT33063
9-11 minutes (a PC with 15" CRT monitor)
17-19 minutes (a PC with 15" LCD monitor)
2.58(5.67)
No
350
700VA
Style A UPSx3, Bypassx3
Simulated sine wave at 120V +/- 5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously. If load exceeds 120% of nominal for
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automatically.
UPS output shuts off immediately
1140 Joules, 2ms
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continuous beeping sound
3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?
<40dBA (1 meter from surface)
850VA
ULT33064
16-20 minutes (a PC with 15" CRT monitor)
36-40 minutes (a PC with 15" LCD monitor)
4.1(9.1)
No
425
850VA
Style A UPSx4, Bypassx4
Simulated sine wave at 120V +/- 5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously. If load exceeds 120% of nominal for
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automatically.
UPS output shuts off immediately
1520 Joules, 2ms
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continuous beeping sound
3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?
<40dBA (1 meter from surface)

Advertisement

loading

This manual is also suitable for:

Ult33063Ult33064Ult33061