1.
Pipe ¾" or 1" inlet and outlet service piping, according to the print, and arrows on bypass.
2.
Set brine tank in place on a clean, level surface. This prevents bottom puncture when weight of
water and salt are added. Connect brine line (furnished in brine tank) from brine tank to valve. Line
must be air tight.
3.
Connect 5/8" OD poly tubing (not supplied) from valve to suitable drain.
male adapter. It
valve to overflow fitting on brine tank.
4.
Test Water, and set computed grains of hardness, and number of people in family to appropriate
setting.
5.
Turn large dial on valve from service position to backwash position. Now, very slowly open bypass
valve (do not open all the way until all air has been removed from resin tank). Open bypass to FULL
service and let run, (5 minutes minimum).
6.
Slowly turn large dial to (brine refill) position and let run until all air is removed from brine line,
(1 minute minimum).
7.
Fill brine tank with water until approximately 1" above the grid.
8.
Turn dial to next position (service).
9.
Plug attached power cord into 120V AC outlet. Press red button and set the time of day to the actual
time of day.
10. Fill brine tank with salt. Peerless recommends Hardi-Cube, Dura-Cube or Mini-Cube or salt substitutes,
i.e. Potassium Chloride, (trade names) K-Life or Soft Touch. These are recommended for their high solu-
bility and pureness. The use of softening agents such as rock, solar or block salt will Negate the
Warranty on your equipment as they are not pure enough and will cause possible problems for
your equipment.
11. Open cold water valves in house to relieve air. Let water run for 3 minutes and test cold water to make
sure it is soft.
12. Hot water from the water heater (unless drained and filled with soft water) will not become soft until the
customer has used approximately 3 times the holding capacity of the water heater.
13. Write the installation date (month/year) on the sticker found on the front of the cover that fits over the
control valve.
Peerless FM/FM-M Softeners
WILL
crack drain housing on valve. Also,
Start-up Procedure
DO NOT
DO NOT
use ½" copper
connect drain line from control
Rev. 02/2009