FAR Rubinetterie S.p.A. - www.far.eu
SOLARFAR units allows use of a solar thermal system in combination with a boiler. The domestic hot water source is selected on the basis of the
temperature detected by the solar storage-tank sensor.
Art.3090
Solar unit for systems with thermal integration
• Solar mixer with 25-65°C temperature range
• 3/4" diverter valve with 230V 8s actuator with manual release
• Max. pressure: 10 bar
• Max. temperature: 110°C
• Non-return valves on the inlets
• EPDM sealing gaskets
• Insulation
• Remote thermostat with immersion sensor
• Connections with 3/4" unions
Solar unit with thermal integration
When the temperature of the water in the storage tank
exceeds the set value (45°C) indicated on the capillary
thermostat, the 3-way zone valve will divert the flow to
the thermostatic mixer, making it available to users.
If the stored water temperature falls below the set
point, the 3-way zone valve will re-direct the water
to the boiler, which heats the water to the desired
temperature.
Solar unit without thermal integration
Once the temperature of the water in the storage
tank exceeds the set value (45°C) indicated on the
capillary thermostat, the 3-way zone valve will divert
the flow to the thermostatic mixer, making it available
to users. If the stored water temperature falls below
the set point, the hot water will be supplied directly
from the boiler.
INSTALLATION
The illustrations below show both correct and incorrect solar unit installation.
Installation Instruction
UNITS FOR SOLAR THERMAL SYSTEMS
Water temperature produced by
solar thermal system: T>45°C
Art.3090
COLD
DOMESTIC
WATER
Water temperature produced by
solar thermal system: T>45°C
Art.3091
Art.3090 - Art.3091
Art.3091
Solar unit for systems without thermal integration
• Solar mixer with 25 -65°C temperature range
• 3/4" diverter valve with 230V 8s actuator with manual release
• Max. pressure: 10 bar
• Max. temperature: 110°C
• Non-return valves on the inlets
• EPDM sealing gaskets
• Insulation
• Remote thermostat with immersion sensor
• Connections with 3/4" unions
USERS
SOLAR
SYSTEM
WATER
SOLAR
SYSTEM
WATER
COLD
USERS
DOMESTIC
WATER
Water temperature produced by
solar thermal system: T<45°C
BOILER
COLD
DOMESTIC
WATER
SOLAR
USERS
SYSTEM
WATER
Water temperature produced by
solar thermal system: T<45°C
USERS
Art.3090-3091
HOT
WATER FROM
THE BOILER

Advertisement

loading

Summary of Contents for FAR 3090

  • Page 1 FAR Rubinetterie S.p.A. - www.far.eu Art.3090-3091 Installation Instruction UNITS FOR SOLAR THERMAL SYSTEMS Art.3090 - Art.3091 SOLARFAR units allows use of a solar thermal system in combination with a boiler. The domestic hot water source is selected on the basis of the temperature detected by the solar storage-tank sensor.
  • Page 2: Wiring Scheme

    FAR Rubinetterie S.p.A. - www.far.eu Art.3090-3091 MIXER REGULATION Once the temperature has been set, it is possible to lock the handle by pressing the screw. SELECTOR TEMPERATURE POSITION °C The thermostatic mixer can rotate through 360°, thus facilitating connections, according to the Reference Notch layout of the system.
  • Page 3: Maintenance

    Position of supply from the mixer Position of supply from the boiler TECHNICAL ASSISTANCE Should technical assistance be required, do not operate and contact: Ufficio Tecnico - FAR Rubinetterie SpA Via Morena, 20 28024 GOZZANO (NO) tel. 0039 0322.94722/956450 - fax 039 0322.93952...
  • Page 4 FAR Rubinetterie S.p.A. - www.far.eu Art.3090-3091 ART. 3090 34 INSTALLATION OVERVIEW SOLAR SYSTEM WITH FORCED CIRCULATION AND MODULATING BOILER WITH THERMAL INTEGRATION MODULATING BOILER (or with storage tank)) Temperature probe Temperature gauge Pump Shut-off valve USERS Non-return valve WATER WORKS...
  • Page 5 Температура воды из Гелиогруппа для систем с бойлером для гелиосистемы > 45°C установок с возвратом потока Арт.3090 КОТЕЛ Когда температура воды, находящейся в бойлере солнечного нагрева, выше значения, установленного на термостате (45°C), трехходовой кран отводит ХВС поток к термосмесителю пользовательской системы. ХВС...
  • Page 6 FAR Rubinetterie S.p.A. - www.far.eu Арт.3090-3091 РЕГУЛИРОВКА СМЕСИТЕЛЯ После регулировки температуры можно заблокировать ручку регулировки ПОЛОЖЕНИЕ ТЕМПЕРАТУРА РУЧКИ °C Термосмеситель можно поворачивать на 360°, что позволяет ориентировать подключения в зависимости от конфигурации установки. РИСКА ДЛЯ РЕГУЛИРОВКИ ЭЛЕКТРОПРОВОДКА ВНИМАНИЕ! Не работать под напряжением! ВНИМАНИЕ! Не...
  • Page 7 FAR Rubinetterie S.p.A. - www.far.eu Арт.3090-3091 ХАРАКТЕРИСТИКИ ПРИВОДА Можно distinguere se l’impianto è alimentato от котла o dal circuito солнечного нагрева in base alla posizione della manopola привода: • Время вращения: 8 сек • Потребляемая мощность: 4,5 VA СОЛНЕЧНОГО НАГРЕВА...
  • Page 8 FAR Rubinetterie S.p.A. - www.far.eu Арт.3090-3091 ПРИМЕР ПРИМЕНЕНИЯ АРТИКУЛА 3090 34 УСТАНОВКА СОЛНЕЧНОГО НАГРЕВА С ПРИНУДИТЕЛЬНОЙ ЦИРКУЛЯЦИЕЙ И МОДУЛИРУЮЩИЙ С ВОЗВРАТОМ ПОТОКА МОДУЛИРУЮЩИЙ КОТЕЛ (или с накопителем) Датчик температуры Термометр Циркулятор Клапан запорный ПОЛЬЗОВ. Клапан обратный СЕТЬ ВОДОСНАБЖ. 1- БЛОК СОЛНЕЧНОГО НАГРЕВА С ИНТЕГРАЦИЕЙ...

This manual is also suitable for:

3091